Contemporary Research 232-FMA manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Contemporary Research 232-FMA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Contemporary Research 232-FMA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Contemporary Research 232-FMA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Contemporary Research 232-FMA should contain:
- informations concerning technical data of Contemporary Research 232-FMA
- name of the manufacturer and a year of construction of the Contemporary Research 232-FMA item
- rules of operation, control and maintenance of the Contemporary Research 232-FMA item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Contemporary Research 232-FMA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Contemporary Research 232-FMA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Contemporary Research service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Contemporary Research 232-FMA.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Contemporary Research 232-FMA item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    17630 Davenport Road, Suite 113 • Dallas, TX 75252 Phone: 972-931-2728 • Toll-Free: 888-972-2728 • Fax: 972-931-2765 E-Mail: Sa le s@ cr www.c om • W eb si te : www. cr www.c om Product Manual 232- FMA Stereo FM Tuner Rev 1.3 August 11, 2005[...]

  • Page 2

    Contemporary Research 2 232-FMA F M Stereo Tuner Table of Contents Overview ............................................................................................................................... .............. 3 Specifications ..................................................................................................................[...]

  • Page 3

    Overview The Contemporary Research 232-FMA is a versatile RS-232 controlled FM tuner featuring stereo audio, 10-preset memory, front-panel operation and feedback, and intelligent control. Fully programmable, the unit can restore all settings on power-up from non-volatile memory. The front-panel buttons and LED display can be used for general operat[...]

  • Page 4

    Specifications Physical Size: 8.5" [216mm] wide x 1.75" [38 mm] height (1RU) x 6.0" [153mm] deep Weight: 1.25 lbs [0.57kg] Enclosure: All aluminum with durable black powder coat paint Mounting: Rack mounting for one or two units side-by-side optional (RK1, RK2) Front Panel Push Buttons: Preset up and down, Seek up and down, and Mute [...]

  • Page 5

    Contemporary Research 5 232-FMA F M Stereo Tuner Front Panel Programming To Enter a Front Panel Programming Mode: 1. Press and hold the Mute A/V button such that the red LED light above is lit (indicating Mute On). 2. Press Seek Up. 3. Release all buttons, the 232-FMA will now be in the front panel programming mode. 4. The front panel display is de[...]

  • Page 6

    Contemporary Research 6 232-FMA F M Stereo Tuner Mode 9: Treble setting fixed at 0dB Front Panel Programming Quick Reference Mode: Parameter: FM Tune 0 .0 FM odd frequencies (US standard) 1 FM even and odd frequencies (international) Baud Rate 1 .1 300 2 600 3 1200 4 2400 5 4800 6 9600 Unit Number 2 .1 one 2 two 3 three Not Used 3 .0 Panel Lockout [...]

  • Page 7

    Contemporary Research 7 232-FMA F M Stereo Tuner RS-232 Control Protocol Overview The 232-FMA full duplex RS-232 scheme enables a system programmer to control all FM Tuner functions as well as monitor 3 groups of FM Tuner status. All commands ar e sent as ASCII strings. No delays between characters or commands are required, as data is interrupt dri[...]

  • Page 8

    Contemporary Research 8 232-FMA F M Stereo Tuner General RS-232 Commands TT= Select tuned frequency Example: ‘ >TT=94.5 87.7-108.0 Selects preset 94.5, if currently stored as a Preset TC= Force tuned frequency Example: ‘ >TC=101.9’ 87.7-108.0 Selects preset 101.9 regardless of current Presets TP Set to previous preset Accesses previousl[...]

  • Page 9

    Contemporary Research 9 232-FMA F M Stereo Tuner Terminal Communication Commands EF Echo Off Characters received will not be re-transmitted (power up default) EN Echo On Characters received will be re-transmitted. Example: ‘ >EN’ Characters receive d will be re-transmitted. ID Product ID Returns the product model number and software version.[...]

  • Page 10

    Response Strings Typical: [Attention] [Unit#] [data ...data] [cr] [lf] 232-FMA status response strings contain ASCII characters similar to those used for the same functions in command strings. An ASCII 'carriage return' and ‘line feed' follow each response string. Frequency/Source Status Response String Audio Status Response String[...]

  • Page 11

    Control Cable Connections All drawings show pin numbers relative to a PC COM port or Axcent3 DB-9 RS-232 control port. Pin-outs to other types of control ports may vary. Pins 4 and 9 are momentary closures to GND (5). Single Tuner 5 GND 2 RXD 3 TXD RXD 2 GND 5 TXD 3 Control Wi ri ng – Single Unit 9-pin D- sub female RS-232 Control Port Pres et Up[...]

  • Page 12

    Rack Mounting Two options are available for rack-mounting tuners. RK1 Rack Mount RK2 Rack Mount RK1 Single Unit Rack Mount Size Long Bracket: 9.5" [206mm] wide x 1.75 " [38mm] height (1RU) x 1.75” [38mm] deep Size Short Bracket: 1.0" [22mm] wide x 1.75 " [38mm] height (1RU) x 1.75” [38mm] deep Weight: 3.25 oz [0.148kg] Enclo[...]

  • Page 13

    Contemporary Research 13 232-FMA FM Stereo T uner Safety Instructions Read before operating equipment 1. Cleaning - Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning. 2. Power Sources - Use supplied or equivalent UL/CSA approved low voltage DC plug-in transformer.[...]

  • Page 14

    Contemporary Research 14 232-FMA FM Stereo T uner Limited Warranty and Disclaimer Contemporary Research Corporation (CR) warrant s this product to be free from defects in material and workmanship under normal use fo r a period of two years from the date of purchase from CR. Should such a defect occur CR will repair or replace, at their option, the [...]