Cleveland Floor Type Gas Convection Steamer 24CGA10.2 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Cleveland Floor Type Gas Convection Steamer 24CGA10.2, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Cleveland Floor Type Gas Convection Steamer 24CGA10.2 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Cleveland Floor Type Gas Convection Steamer 24CGA10.2. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Cleveland Floor Type Gas Convection Steamer 24CGA10.2 should contain:
- informations concerning technical data of Cleveland Floor Type Gas Convection Steamer 24CGA10.2
- name of the manufacturer and a year of construction of the Cleveland Floor Type Gas Convection Steamer 24CGA10.2 item
- rules of operation, control and maintenance of the Cleveland Floor Type Gas Convection Steamer 24CGA10.2 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Cleveland Floor Type Gas Convection Steamer 24CGA10.2 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Cleveland Floor Type Gas Convection Steamer 24CGA10.2, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Cleveland service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Cleveland Floor Type Gas Convection Steamer 24CGA10.2.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Cleveland Floor Type Gas Convection Steamer 24CGA10.2 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Part s Manual Floor type Gas Convection S teamer Series: S teamCraf t Model 24CGA10.2 1333 East 179 th Street Cleveland, Ohio 441 10 Phone: (216) 481-4900 1-800-338-2204 Fax: (216) 481-3782 www .clevelandrange.com[...]

  • Page 2

    [...]

  • Page 3

    [...]

  • Page 4

    [...]

  • Page 5

    [...]

  • Page 6

    [...]

  • Page 7

    [...]

  • Page 8

    [...]

  • Page 9

    [...]

  • Page 10

    Statement of Re sponsibilities This document is for use by experienced and traine d Qualifie d Cleveland Range, LLC Authorized Service Representatives who are familiar with both t he safety procedure s, and eq uipment they service. Cleveland Range, LLC a ssumes no liability for any death, injury, equipment damage, or property damage resulting from [...]

  • Page 11

    Cle v eland Range Inc. 1333 East 179th St., Cle veland, Ohio , U .S.A. 44110 Ph : 1-216-481-4900 Fx : 1-216-481-3782 Visit our Web Site at www .clevelandrange.com MODEL :  24-CGA- 10.2 ITEM NUMBER __________________________________________ JOB NAME / NUMBER __________________________________ Cleveland Standard Features ■ Cooking Capacity f or [...]

  • Page 12

    (NOT T O SCALE) SECT . IV PA GE 14 0402 Litho in U.S.A. GAS ELECTRIC COLD W A TER CLEARANCE DRAINA GE 1 1 ⁄ 4 ˝ IPS line size, 3 ⁄ 4 ˝ (13mm) connection 120V -1Phase, 60 Hz. 35 psi minimum RIGHT = 3˝ operating, 1 1 ⁄ 2 ˝ dia. NA TURAL PROP ANE BTU 2 Blowers & Controls 60 psi maximum 12˝ if adjoining wall or Do not connect other Pipin[...]

  • Page 13

    CLEVELAND RANGE GEMINI 24CGA 6.2 AND 24CGA10.2 SEQUENCE OF OPERATIONS Mechanical Timer Starting with the timed manual switch in the tim ed position, and no time on the timer. 1. To turn the unit on, turn the ON/O FF lever clockwise to the ON position • This mechanically closes the drain. • The red “Power On” indicator is energized. • 115 [...]

  • Page 14

    • The fan prover switch makes allowing 24 VAC to the normally open R2 contacts. • The normally open R2 contacts close and 24 VAC is sent to the main coil of the gas valve. • The main burner is ignited and the water heated to steam . • Steam enters the cabinet and the compar tm ent thermostat closes at 193 degrees. • The “Sure Cook” li[...]

  • Page 15

    BUZZER VALVE BLOWER MOTO R MV GAS VALVE DESCALE REQUIR ED INDICATOR GEMINI GAS - MECHANICAL TIMER 24V IGNITOR PROVE R MV/PV SPARK CONTROL M OD SINGLE COMPAR TM ENT SHOWN DUPLICATE FOR SE CO ND COMPARTM ENT GND GND SPARK 24V 24V GND R1 PV MV C NO PV TIMER DOOR MAGNETIC 120V TRANSFORME R ELECTRO-MECH ANICAL OVER TEMP HI LIMIT GENERATOR MANUAL TIMED B[...]

  • Page 16

    WHT WHT/RED YEL YEL SW1 BLU WHT/RED GRA RED BLK C BLK NC NO NC SW2 NO C BLU GRN GRN BLK RED RED WHT/RED BLK TAN TAN PNK 8 7 PRP PRP 3 2 4 5 1 6 BLU HEAT LT BLU ORN WHT 9 FILL H N XL HI C RED WHT 5 MV/PV GND (BNR) 24V (GND) 4 MV 1 PV 3 2 24V 7 6 5 11 10 GRA WHT YEL 2 13 BLU WHT/OR N YEL WHT/OR N BLU WHT/OR N PRP PNK PRP BLK BLK WHT/RED BL K BLK WHT/[...]

  • Page 17

    GND SPARK CONTROL MOD GAS VALVE DUPLICATE FO R SECOND COMPART M ENT SINGLE COMPARTMENT SHOWN L300096 C TRANSFOR MER ELECTRONIC BLOWER PROVER IGNITOR 24V SPARK GND MV/PV MV PV GND 24V 120V 24V TRANSFOR MER FU TIMER 24 VAC R1 PV R2 C NO MV R1 C NC M BLOWER MOTOR NO NO NC COMMON TO UPPER AND LO WER COMPARTMENTS GEMINI GAS - ELECTRONI C TIMER DESCALE R[...]

  • Page 18

    WHT/ORN GEMINI GAS / ELECTRONIC TIM ER WHT/RE D BLK BLK 23 25 WHT YEL YEL BLK RED PRP 27 GRA 26 ORN BLK BLK 24 18 BLU BLK 4 LT BLU 5 PV PV/MV MV 2 15 WHT/ORN GRN GRN ORN BLU 1 4 13 27 6 5 89 WHT YEL YEL SPARK 3 GND (BNR) 24V (GND) 24V MV/PV MV PV 22 GRN WHT/ORN YEL YEL YEL BLU PRP 12 GRA RED BLK WHT/RE D 13 BLK RED WHT 7 4 PRP 3 6 2 1 5 8 FILL ORN [...]

  • Page 19

    Adju st or re place the on/o ff micro swi tch Y es Con nect power t o steamer. No Is the red light on? Is t here power to t he steamer? Is th ere water in the sig ht glass? Y es S ee Steame r won't fi ll. No Has the pilot ig nited? Y es No Do es the steamer s team in manual mod e? Y es R eplace t he timer Y es Is th ere power to the Timed/Manu[...]

  • Page 20

    PROBLE M: 24CG A6 24CGA10 .2 Steamer won't fill with the ha ndle in the on p osition Is t here power to the steamer? Co nnect po wer to the steamer No Is t here water to t he steamer? Y es S upply wa ter to the steamer. No Is ther e 120 VAC b etween the termin als H and N on the watr level b oard? Y es Adju st or repl ace on/off micro switch N[...]

  • Page 21

    Is ther e 120 VAC b etween the term inals Heat and N o n the water lev el board with the the low probe su bmerged? Is ther e 120 VAC bet ween Heat and N termi nals on the water lev el board with a ju mper between termi nal XL and C? No C lean or re place the pr obe assy. Re place water l evel board. No Y es Is ther e 120 VAC acros s the primary of [...]

  • Page 22

    PROBLE M: 24CGA6, 24CGA10 .2 Electronic timer displays "PAUS" and won't count down ST ART Is steam heating th e cooking ca binetabove 192 degr ees (the set te mp of the thermo -switch)? Doe s the timer coun t down when the th ermo-switch is b ypassed? Y es S ee Ste amer won't steam No Re place the elec tronic timer No Re place t[...]

  • Page 23

    Descaling Procedure-SteamCraft Ultra and Gemini Series 1. Turn the unit OFF and open the doors: This will drain and rinse the generato r for about 3 minutes. 2. Turn the unit power back On: The generator will begin to refill with water. 3. Select Timed with the Timed/Manual switch: DO NOT start the timer, since you do not want to heat the water dur[...]