Cleveland Range SEL-30-T1 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Cleveland Range SEL-30-T1, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Cleveland Range SEL-30-T1 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Cleveland Range SEL-30-T1. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Cleveland Range SEL-30-T1 should contain:
- informations concerning technical data of Cleveland Range SEL-30-T1
- name of the manufacturer and a year of construction of the Cleveland Range SEL-30-T1 item
- rules of operation, control and maintenance of the Cleveland Range SEL-30-T1 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Cleveland Range SEL-30-T1 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Cleveland Range SEL-30-T1, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Cleveland Range service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Cleveland Range SEL-30-T1.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Cleveland Range SEL-30-T1 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    SE95051 Operators Manual Installation, Operation & Service Electric T1 Skillets 1333 East 179th St., Cle v eland, Ohio , U .S .A. 44110 Phone: (216) 481-4900 F ax: (216) 481-3782 Visit our web site at www .cle v elandrange .com MODELS : SEL-30-T1 SEL-40-T1 Enodis[...]

  • Page 2

    FOR THE USER IMPOR T ANT THE INST ALLA TION AND CONNECTION MUST COMPL Y WITH THE LOCAL AND NA TIONAL ELECTRICAL CODES . ENSURE ELECTRICAL SUPPL Y CONFORMS WITH ELECTRICAL CHARA CTERISTICS SHO WN ON THE RA TING LABEL ALL SER VICE MUST BE PERFORMED BY A QU ALIFIED CLEVELAND RANGE TECHNI- CIAN. RET AIN THIS MANUAL FOR YOUR REFERENCE. W ARNING : Improp[...]

  • Page 3

    T ABLE OF CONTENTS Installation General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Inspection / Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Shipping Damage Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Installation . . . . . . . . . .[...]

  • Page 4

    1 GENERAL Installation of the unit must be accomplished by qualified electrical installation personnel working to all applicable local and national codes. Improper installation of pr oduct could cause injury or damage. This equipment is built to comply with applicable standards for manufactur ers. Included among those approval agencies ar e: UL, NS[...]

  • Page 5

    2 WIRE CONNECTION Note: Ensure main power is turned off befor e connecting wires. General Information Install in accordance with local codes and/or the National Electric Code ANSI/NFP A No. 70-1990 (USA) or the Canadian Electric Code CSA Standard C22.1 (Canada). A separate fused dis- connect switch must be supplied and installed. The unit must be e[...]

  • Page 6

    3 DPK (OPTION) 39" 991mm 35" 889mm (RIM HEIGHT) 71" 1804mm 75 28 3/4" 731mm (P AN SURFACE) A B (P AN SURF ACE) 41" 1042mm H C 25 15/16" (659mm) 3 7/8" (99mm) C 5 1/4" (134mm) (FAUCET OPEN) 30" (762mm) 5" (127mm) (MANUAL TIL T HANDLE) D RECOMMENDED FLOOR SLOPE 1" (26mm) IN 4' (1220mm) FLOOR[...]

  • Page 7

    4 OPERA TING INSTRUCTIONS General Parts Drawing ITEM # DESCRIPTION FUNCTION 1. Power Switch Lower position - power to the unit is OFF . Upper position - power to the unit is ON. 2. T emperature Dial Regulates the surface temperature of the pan. 3. Heat Indicator Light T ur ns ON when heating system is on and OFF when system is off. 4. Hand Tilt Whe[...]

  • Page 8

    5 OPERA TING THE UNIT 1. Ensure electrical supply to the unit is in the ON position. 2. T ur n Power Switch ( 1 ) to the ON position. The yel- low Heat Indicator Light ( 3 ) will indicate power is on. 3. MANUAL TIL T ( 4 ) : Cleveland skillets are equipped with a manual tilt mechanism for raising and lowering the pan. T o raise pan, raise the cover[...]

  • Page 9

    6 CARE AND CLEANING Y our skillet must be cleaned regularly to maintain its fast, efficient cooking performance, and to ensure its continued safe, reliable operation. W ARNING: Do not use chloride base detergents. There is a gr owing number of non-chloride cleaners available. If unsure of the cleaners chlorine content consult the supplier . Also av[...]

  • Page 10

    7 F AUCET ASSEMBL Y ITEM P ART DESCRIPTION QTY . NO . NO . 1. KE50825-7 3/4" SPOUT . . . . . . . . . . . . . . . . . . . . . . . .1 2. F A95022 RET AINING RING . . . . . . . . . . . . . . . . . . . .1 3. F A05002-19 "O" RING . . . . . . . . . . . . . . . . . . . . . . . . . . .1 4. KE51736 LONG F AUCET NUT . . . . . . . . . . . . . .[...]

  • Page 11

    8 P AN MOUNT ASSEMBL Y ITEM P ART DESCRIPTION QTY . NO . NO . 1. HEA TING ELEMENTS . . . . . . . . . . . .6 3 3 0 0 G G A A L L L L O O N N SK50845-1 ELEMENT , 2.00 KW , 480 V AC SK50845-2 ELEMENT , 2.67 KW , 416 V AC SK50845-3 ELEMENT , 2.00 KW , 416 V AC SK50845-4 ELEMENT , 2.67 KW , 240 V AC ELEMENT , 2.00 KW , 208 V AC SK50845-5 ELEMENT , 2.00 [...]

  • Page 12

    9 ITEM NO . P ART NO . DESCRIPTION QTY . 1. KE51730 TIL T SHAFT BEARING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. F A31010 LOCK W ASHER, 3/8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 3. F A20030 HEX NUT , 3/8-16 . . . . . . . . . . . . . . . . . .[...]

  • Page 13

    10 17. KE50315 WORM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 18. F A95005 TENSION PIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 19. KE52193 THRUST BEARING SP ACER . . . . . . . . . . . . . . . . . . . . . . . . . . [...]

  • Page 14

    11 1 2 11 9 12 15 10 14 13 3 4 5 6 7 8 8 9 9 16 SECTION A - A SECTION B - B SECTION C - C B A AB C C WARNING : Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. AVERT[...]

  • Page 15

    12 COMPONENT PL A TE ASSEMB L IES ITEM P ART DESCRIPTION QTY . NO . NO . M M A A N N U U A A L L T T I I L L T T 1. SK00411 COMPONENT PLA TE WELDMENT .1 2. SK2475500 RELA Y . . . . . . . . . . . . . . . . . . . . . . . .1 3. SK2475600 HOLDER . . . . . . . . . . . . . . . . . . . . . .1 4. SK2475700 SPRING . . . . . . . . . . . . . . . . . . . . . .[...]

  • Page 16

    13 FRAME / LID ASSEMBL Y ITEM NO . P ART NO . DESCRIPTION QTY . 1. SK00392-1 FRAME WELDMENT (30 GALLON) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 SK00392-3 FRAME WELDMENT (40 GALLON) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. SK2457192 LID ASSEMBL Y (30 GALLON) . . . . . . . . . . . . . . . . [...]

  • Page 17

    14 1 2 3 4 5 6 7 2" T ANGENT DRA W-OFF V AL VE ITEM NO . P ART NO . DESCRIPTION QTY . 1. - 7. KE50972-B DRAW-OFF ASSEMBL Y . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 1. F A95049 WING NUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. [...]

  • Page 18

    15 W ARNING : Any maintenance or service involving disassembly of components should be made by a qualified service technician. Ensure electrical and water supply (if applicable) to the unit are shut of f. ! LUBRICA TION PROCEDURE Lubricate the following parts ever y three months to insure smooth operation and r educe wear . TRUNNION HOUSING, WORM S[...]

  • Page 19

    16 SEQUENCE OF OPERA TIONS When using these instructions refer to the SEL-TI wiring schematic. 1. Supply V oltage is sent to the primar y of the 120 V AC transformer . 2. Supply voltage is sent to the normally open con- tacts of the Heat Contactors, C 1 and C2. 3. 120 V AC is sent from the secondary of the 120V AC transformer through the 3 amp fuse[...]

  • Page 20

    17 P ART NO . DESCRIPTION QTY . H H E E A A T T I I N N G G E E L L E E M M E E N N T T S S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 30 GALLON SK50845-1 ELEMENT , 2.00 KW , 480 V AC SK50845-2 ELEMENT , 2.67 KW , 416 V AC SK50845-[...]

  • Page 21

    18 WIRING DIAGRAM RESISTOR ELECTRICAL COMPONENT PART #s FUSE 3A KE52936-6 10 FUSE 1.25A KE52936-8 10 RELAY 1 SK2475500 12 HEATING ELEMENTS - SEE "PAN MOUNT ASSEMBLY" ON PAGE # 8 ON/OFF SWITCH SK2474103 11 HIGH LIMIT KE55069-7 8 THERMOSTAT SK2142002 11 SENSOR SK50933-1 8 HEAT INDICATOR SK50905-1 16 CIRCUIT BREAKER KE50579-1 10 MERCURY SWIT[...]

  • Page 22

    19 19 ON MARCHE ENCENDIDO ACCESO AN P AUSE, INTERRUPTION P AUSE, INTERRUPTION P AUSA, INTERRUPCION P AUSA, INTERRUZIONE P AUSE, UNTERBRECHUNG RESET RÉENCLENCHER RECONECT AR RESET NULLSTELLEN STOP OF ACTION ARRÊT DE L'ACTION P ARAR FUNCIONAMIENTO ARRESTO OPERAZIONE FUNKTION STOPPEN F AST STOP , EMERGENCY ARRÊT RAPIDE D'URGENCE P ARADA R[...]

  • Page 23

    20 20 LOW W A TER NIVEAU BAS DE L'EAU NIVEL DE AGUA BAJO LIVELLO BASSO W ASSERST AND NIEDRIG IGNITION F AILURE P ANNE D'ALLUMAGE F ALLO DE ENCENDIDO MANCA T A ACCENSIONE ZÜNDUNGSFEHLER COOLING REFROIDISSEMENT REFRIGERACION RAFFREDDAMENTO KÜHLUNG MIXER BRIDGE PONT DU MÉLANGEUR PUENTE DE MEZCLADORA MENSOLA MESCOLA TORE MISCHER-BRÜCKE RI[...]