CFM UVC43 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of CFM UVC43, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of CFM UVC43 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of CFM UVC43. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of CFM UVC43 should contain:
- informations concerning technical data of CFM UVC43
- name of the manufacturer and a year of construction of the CFM UVC43 item
- rules of operation, control and maintenance of the CFM UVC43 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of CFM UVC43 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of CFM UVC43, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the CFM service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of CFM UVC43.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the CFM UVC43 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    V ent-Free Gas Room Heaters Homeowner's Installation and Operating Manual PLEASE READ THIS MANUAL BEFORE INST ALLING AND US - ING APPLIANCE. IMPORT ANT : Read all instruc- tions and warnings carefully be- fore starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty . W ARNING[...]

  • Page 2

    2 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 Installation & Operating Instructions Important Curing/Burning Instructions ................................................................................. 3 Fireplace Dimensions ...............................................................................................[...]

  • Page 3

    3 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 Installation & Operating Instructions This gas room heater should be installed by a qualified installer in accordance with local building codes and with current Na- tional Fuel Gas Code. ANSI Z223.1/NFP A 54. "This heater shall not be installed in a confined space or u[...]

  • Page 4

    4 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 36" 34 ³⁄₄ " 32 ³⁄₄ " 5 ³⁄₄ " 3 ¹⁄₄ " 7 ³⁄₄ " 2"  21" 1" 20" 9" 4" 33" 34 ¹⁄₄ " 36" 36" 51" 25 ¹⁄₂ " Rough Opening Width 36 ¹⁄₂ " Finished Wal[...]

  • Page 5

    5 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 Safety Devices Adequate combustion and ventilation air must be pro- vided. The flow of combustion and ventilation air MUST NOT be obstructed. Provide adequate clearances around the air opening into the combustion chamber; and adequate accessibili- ty clearance for servicing and [...]

  • Page 6

    6 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 Hearth Extension A hearth extension in front of heater is recommended but not required. Planning Planning the installation is an important first step: it will save time and money later in the actual installation. In planning the installation, consider: 1. Where the heater will b[...]

  • Page 7

    7 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 GF443 UVC (from GF379) 2/11/97 Parts Identification Fig. 6 Parts identification. FP443 Catalytic Filters (Behind Grille) UVC T op Louvre Screen Panel (UVS) Glass Panel (UVC) Firebox Bottom Louvre (Bottom Access Door) (Controls behind louvre) Gas Line Access Nailing Flange Logs [...]

  • Page 8

    8 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 Always check for gas leaks with a mild soap and water solution. Do not use an open flame for leak testing. The gas control is equipped with a captured screw type pressure test point, therefore it is not necessary to pro- vide a 1/8" test point up stream of the control. When[...]

  • Page 9

    9 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 2. Attach wire to switch and install switch into recep- tacle box. Attach cover plate to switch. 3. Connect wiring to gas valve. (Fig. 10) Alternate Switch Location Remote switch can be installed on either side of the access door . Simply mount the switch to the switch bracket pr[...]

  • Page 10

    10 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 Glass Information (UVC Only) Only glass approved by CFM Specialty Home Products should be used on this fireplace. • The use of any non-approved replacement glass will void all product warranties. • Care must be taken to avoid breakage of the glass. • Do not operate applia[...]

  • Page 11

    1 1 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 7. Place top left log (BE9 or BF1 1) onto locator notches. Ensure log is secure. 8. Place top right log (BE10 or BF12) onto locator notches. Ensure log is secure. Ember Material Placement Separate the ember material into small pieces and place onto the burner in front of the fr[...]

  • Page 12

    12 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to "OFF". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. T urn off all electrical power to the fireplace. 3. For MN/MP/TN/TP appliances[...]

  • Page 13

    13 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 • Gas Supply On • Supply line hooked up • Shutoff valve open NO NO NO NO • Lockout has engaged. W ait 60 seconds and try again • For spark at electrode while depressing Piezo 1/8" gap to pilot hood needed • All wiring connections • Replace Piezo ignitor • Fo[...]

  • Page 14

    14 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 Maintenance Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out. Remove and replace the logs as per the[...]

  • Page 15

    15 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 13 12 10 11 8 6a/b 22 18 17 26 7 9 23 a/b 2 3 4a/b 5 25 20a/b 27 15 28 19 1 1a 1b 1c 1d 1e UVC/UVS36 1a 1b 1c 1d 1e UVC/UVS43 1 14 19 0135 UVC/UVS36/43 Parts 9/8/00 djt 21 16 24 30 0135 CFM Specialty Home Products reserves the right to make changes in design, materials, speci[...]

  • Page 16

    16 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 Contact CFM Specialty Home Products for questions concerning prices and policies covering replacement parts. Parts may be ordered through your Majestic Fire- places distributor or dealer . Y ou will need the following information when ordering replacement parts: 1. The heater mo[...]

  • Page 17

    17 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 Optional Accessories Fan Kit FK24 Fan Assembly Fan specifications: 120 volt, 60 Hz, .75 Amps This fan does not need regular maintenance, however periodic cleaning is required. Check the area under the control door and in front of the fan and wipe or vacuum at least once a month[...]

  • Page 18

    18 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 Decorative Frame T rims A selection of decorative frame trim kits are available for mounting around the outside of the appliance to en- hance its visual effect on the room. Installation instruc- tions for each decorative frame trim are included with the frame trim kit. Unit Kit [...]

  • Page 19

    19 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 BASIC W ARRANTY CFM Specialty Home Products (hereinafter referred to collectively as the Company) warrants that your new V ermont Castings or Majestic Gas Fireplace/Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject [...]

  • Page 20

    410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www .majesticproducts.com • www.vermontcastings.com CFM Specialty Home Products[...]