Cecilware ME15-GN manual

1
2
3
4
5
6
7
8
9
10
11

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Cecilware ME15-GN, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Cecilware ME15-GN one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Cecilware ME15-GN. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Cecilware ME15-GN should contain:
- informations concerning technical data of Cecilware ME15-GN
- name of the manufacturer and a year of construction of the Cecilware ME15-GN item
- rules of operation, control and maintenance of the Cecilware ME15-GN item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Cecilware ME15-GN alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Cecilware ME15-GN, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Cecilware service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Cecilware ME15-GN.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Cecilware ME15-GN item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    ME10-GN ME15-GN AUTOMATIC GAS WATER BOILER Operation Manual NQ24A 12-2006 CONTENTS Specifications Start up Instructions Trouble Shooting Guide Parts List Wiring Diagram 18 Gauge Type 304L Stainless Steel construction to resist corrosion. Solid State water level control for automatic refill[...]

  • Page 2

    WATER INLET (1/4 " FLARE) 16.0 3.4 SIDE ACCESS DOOR (SLIDES UP) OVERFLOW THERMOMETER 4.0 "B" 14.0 5.0 CAUTION HOT SURFACES ME10-GN NP87A TEMPERATURE CONTROL NOTE: UNIT IS SUPPLIED WITH A GROUNDED 120V-15A LINE CORD AND PLUG (NEMA 5-15P). PROPANE GAS BTU/ HR @ 10" W.C. 12,000 NATURAL GAS BTU/ HR @ 3.5" W.C. GAS SPECIFICATION[...]

  • Page 3

    2 FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. THIS INSTALLATION MUST CONFORM WITH THE NATIONAL FUEL GAS CODE , ANSI Z223.1 (LATEST EDITION). WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH.[...]

  • Page 4

    3 ASSEMBLY: T he four legs and vent cap drain are packed separately with the water boiler. Install legs by tilting the water boiler on its side and screwing the legs into the leg supports until hand tight. Carefully right the unit and install in its permanent location, being sure to leave at least 6” on the right side of the water boiler for acce[...]

  • Page 5

    4 NOTE: On the first lighting it may be necessary to hold the dial for a longer period to allow trapped air to escape from the line. DIAL SETTINGS AND CORRESPONDING WATER TEMPERATURES: “1”= 50F, “10”=198F RELIGHTING: Shut off all gas and wait approximately 5 minutes before relighting the pilot. SHUTTING DOWN: For temporary shut down, turn t[...]

  • Page 6

    5 BURNER: The b urner is factory set for maximum performance. Should further adjustments be required loosen slotted hex screw on side of ventur i and rotate air shutter until flame with soft blue inner core is obtained. BURNER REMOVAL: The burner can be removed with the unit standing in operating position. Turn off the gas flow to the unit. Allo w [...]

  • Page 7

    [...]

  • Page 8

    [...]

  • Page 9

    No. PART # DESCRIPTION ME10-GN ME15-GN 1 B012A HEYCO BUSHING STRAIGHT, SMALL 1 1 2 B033A TERMINAL BLOCK 3 POSITION 1 1 3 C032S LINE CORD W/ PLUG 120V 15A 1 1 4 CD257 WATER INLET VALVE 120V 1 1 5 CH32A THERMOSTAT HARNESS ASSEMBLY 1 1 6 CH415 WIRING HARNESS ASSEMBLY 1 1 7 D022Q FAUCET, SHANK W/ VALVE 1 1 8 D031A GUAGE SHIELD, 14 1/2" 1 0 9 D066A[...]

  • Page 10

    B) Water Inlet Valve Test Turn power OFF. If the water level rises inside a partially filled tank, the Water Inlet Valve is leaking. Disconnect wires from the Water Inlet Valve coil and connect a 2 wire line cord to the terminals. Plug it into a 115V outlet. If water flows in and stops when you pull it out, the Valve is working fine. Repeat this te[...]

  • Page 11

    CECILWARE CORPORATION RED WHT BLU YEL WATER LEVEL CONTROL WATER LEVEL PROBES GND 6 COMMON 4 L-LEVEL 5 H-LEVEL 3 AC-2N 1 FILL 2 AC-1L WATER LED L1 N WATER INLET VALVE POWER LIGHT GND GRN POWER SWITCH N L1 ELECTRICAL DIAGRAM ME10G-N, ME15G-N 120/ 240 VOLTS[...]