Cecilware BC302 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Cecilware BC302, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Cecilware BC302 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Cecilware BC302. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Cecilware BC302 should contain:
- informations concerning technical data of Cecilware BC302
- name of the manufacturer and a year of construction of the Cecilware BC302 item
- rules of operation, control and maintenance of the Cecilware BC302 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Cecilware BC302 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Cecilware BC302, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Cecilware service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Cecilware BC302.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Cecilware BC302 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    BREW CENTER, COFFEE BREWING EQUIPMENT TWIN: BC2, BC302 SINGLE: BC1, BC301, BC120, BC240 MANUAL * Specifications * Start up procedure * Adjustments * Parts Identification * Installation * Operating Instructions * Care Maintenance * Wiring Diagram Cecilware sells value... Worldwide 43 -05 20th Avenue, Long Island City, NY 11105 TEL: 718-932-1414 FAX:[...]

  • Page 2

    2 SPECIFICATIONS ELECTRICAL SPECIFICATIONS MODEL NO. BC1 BC301 BC120 BC240 BC2 BC302 Volts 120/240 120/240 120 240 120/240 120/240 Watts 4100 4100 1800 3120 6200 6280 Amps 18 18 15 13 27 27 Wall Outlet (Receptacle) Power Cord CE202 – 30A optional 6-20R 6-20R 5-15R 6-15R 6-30R 6-30R All Brew Centers are single phase with 3 wires plus a ground with[...]

  • Page 3

    3 INSTALLATION AND OPERATING INSTRUCTIONS Warranty is void if the Brewer is connected to any Voltage other than the Voltage specified on the data label of the Brew er. UNPACKING AND INSPECTION Carefully unpack the Brewer by cutting the st raps and lifting the carton off the Brewer. ASSEMBLY AND SET-UP The Brewer is shipped complete with: DESCRIPTIO[...]

  • Page 4

    4 INITIAL PRIMING – Filling of Tank The BC Brewers are shipped with the Thermostat in the OFF position. Do not turn Thermostat to the ON position until the Brewer has been fully primed. a. Turn water supply on and check for leaks at the water inlet connections. Tighten compression fitting if necessary. b. Turn on power to the Brewer. The Brewer w[...]

  • Page 5

    5 ADJUSTMENTS 1. BY-PASS FLOW VALVE ADJUSTMENTS Depending on the model number, the BC Brewers have been factory set to brew 12, 24 and/or 36 cups of coffee, with the BY-PASS adjusted for a 20% BY-PASS flow of brewing water for the 36 cup, brew output only. Since water hardness, the brand of coffee, and the length of brew time are important factors [...]

  • Page 6

    6 R E MO VE JU MP E R F O R 240V 2. TIMER ADJUSTMENT PROCEDURE Remove the top cover to access the brew timer(s). To INCREASE output: turn timer knob a small increment CLOCKWISE. To DECREASE output: turn timer knob a small increment COUNTER-CLOCKWISE. Check output level in carrier. BCI, BC2 BC120, BC240 BC301, BC302 Single Timer (L264A) Dual Timer ([...]

  • Page 7

    SPECIAL COMPONENTS TEST 1) CHECK DISPENSE VALVES FOR LIME BUILD-UP ( Located inside top cabin ) Drain the water tank to just below the level of the Dispense Valves. Remove the Valves and clean. Y ou can take these valves apart by hand as shown. Replace the assembly as needed. Replace the valve into the tank and refill tank. 2) WATER INLET VALVE (SO[...]

  • Page 8

    8 TROUBLESHOOTING GUIDE WARNING: To reduce the risk of electrical shock unplug the dispenser power cord before repairing or replacing any internal components of the unit.. Before any attempt to replace a component be sure to check all electrical connections for proper contact PROBLEM PROBABLE CAUSE REMEDY 1. No power to the machine. a) Loose wire c[...]

  • Page 9

    9 CLEANING AND SANITIZING SANITIZING: All food dispensing units should be sanitized periodically . All parts to be sanitized must be cleaned first. To prepare a sanitizing solution: ADD 2 TSP. OF LIQUID CLOROX BLEACH (5.25% CONCENTRATION) TO 1 GALLON OF WATER AT ROOM TEMPERATURE (70°- 90°F). Note: Always start with a unopened bottle of Clorox Ble[...]

  • Page 10

    10 PARTS IDENTIFICATION [ * RECOMMENDED SPARE PARTS] SINGLE UNITS BC1, BC301, BC120, BC240 TWIN UNITS BC2, BC302 I TE M P/N QTY P/N QT Y DESCRIPTION 1 SF26A 1 SB49A 1 CABINET TOP COVER 2 --- N829A N892A N822A -- 1 1 1 ---- --- N815A N823A -- -- 1 1 SWITCH PANEL LABELS: BC120 & BC240 BC1 / BC2 BC301 / BC302 5* L155A L155A L155A L155A 2 1 1 1 L15[...]

  • Page 11

    11 TOP CABIN OPEN VIEW TOP CABIN - PARTS IDENTIFICATION [ * RECOMMENDED SPARE PARTS] ITEM SPARE PARTS SINGLE UNITS P/N QTY TWIN UNITS P/N QTY DESCRIPTION 1 * L656A 1 L656A 1 HI-LIMIT 2 * L499A M532A 1 1 L499A M523A 1 1 FLOAT SENSOR WITH RUBBER GASKET 3 * G367A G369A G286A 1 G367A G369A G286A 2 HEATER (1.7 KW 120V) OR HEATER (3.0 KW 230V) OR HEATER [...]

  • Page 12

    12 BOTTOM CABIN OPEN VIEW BOTTOM CABIN - PARTS ID ENTIFICATION [ * RECOMMENDED SPARE PARTS] SPARE PARTS BC301-IT BC2-IT BC302-IT ITEM P/N QTY P/N QT Y DESCRIPTION 1 * L069A 1 L069A 1 POWER SWITCH 2 B083A 1 B083A 1 TERMINAL BLOCK 3 * CD257 1 CD257 1 WATER INLET VALVE 4 * C396A C395A 1 1 C396A C395A 1 1 FUSE HOLDER FUSE 5 * CE202 CG99A 1 CE202 CG99A [...]

  • Page 13

    13 CARRIER ASS’Y 97208 [ * RECOMMENDED SPARE PARTS] Item Description Part # 1 * Handle, black 3” 02015 2 2 * * Hold Down Bracket Thumb Screw U833A M299A 3 * * Carrier Cover S.S. Gasket, Cover Carrier U811A M294A 4 Label NG47A 5 Screw P808A 6 * Faucet Guard U812A 7 * Faucet & Shank Ass’y 8” 99461 8 * Faucet Washer 7227 9 * Faucet Hex Nut[...]

  • Page 14

    14 WHITE RED BLACK BREW CIRCUIT BREW VALVE R W B L L2 N FUSE 6 AMP. RED BLK GND L1 L1 LOAD REFILL CIRCUIT PROBE N HI LIMIT BLK D C.G. BC-1E 120/240 3 WIRES + GROUND 3100 WATTS 14A 1 PH 60Hz C.G. - D FAUCET & SHANK ASS’Y 99461[...]

  • Page 15

    15 BC120E 2 WIRES+GRD 1800W 15A 1PH A C.G. BC240E 2 WIRES+GRD 3120W 13A 1PH C.G. - A BLACK WHITE BC-240E DUAL BREWTIME BC-120E DUAL BREWTIME RED WARMER L2 S L1 SW2 SW3 I2 I1 12 CUP 24 CUP BREW INDICA TOR LIGHT HI LIMIT FUSE 6 AMP. BLK BLK GND L1 N FLOAT SWITCH L1 LOAD PROBE N[...]

  • Page 16

    16 N L1 REFILL CIRCU IT HI LIMIT BLK RED WHITE BLACK 89 11 FUSE 6 AMP. RED BLK BLK N L2 GND L1 INLET VALVE PROBE LOAD C C.G. BC-301E 120/240 3 WIRES+GN D 4140W 18A 1PH 60HZ BC-301E TRIPLE BREW TIME BREW CIRCUIT 10 12 24 3 6 C.G. - C[...]

  • Page 17

    17 C C.G. BC-2E 120/240 3 WIRE+GRD 6230W 26A 1PH 60HZ C.G. - C PROBE PROBE L1 LOAD N HI LIMIT BLK BLACK WHITE RED L BC-2E SINGLE BREW TIME W RB GND RED BLK L2 N L1 L B W R[...]

  • Page 18

    18 WHITE RED BLACK 12 CUP 24 CUP 36 CUP 11 24 CUP 12 CUP 36 CUP 9 8 10 RED BLK N L2 L1 GND D C.G. C.G. - D 24 CUP 12 CUP 36 CUP 24 CUP 36 CUP 12 CUP 11 9 81 0 PROBE LOAD L1 N HI LIMIT BLK[...]