The rules should oblige the seller to give the purchaser an operating instrucion of Carver pm125, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Carver pm125 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Carver pm125. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Carver pm125 should contain:
- informations concerning technical data of Carver pm125
- name of the manufacturer and a year of construction of the Carver pm125 item
- rules of operation, control and maintenance of the Carver pm125 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Carver pm125 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Carver pm125, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Carver service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Carver pm125.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Carver pm125 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    DECLARATION OF CONFORMITY We PHOENIX GOLD INTERNATIONAL, INC. (supplier ’ s name) 9300 N. DECATUR, PORTLAND, OR 97203 USA (address) declare under our sole responsibility that the product pm125 / 420 (name, type or model, lot, batch or serial number, possibly sources and numbers of items) to which this declaration relates is in conformity with the[...]

  • Page 2

    CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous v[...]

  • Page 3

    CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous v[...]

  • Page 4

    pm125 7 6 • 50W per channel into 8 ohms 62W per channel into 4 ohms 125W mono into 8 ohms • 1/4-inch TRS input jacks • Accepts balanced or unbalanced lines • Multi-way binding post output connectors • Independent 11 detent Level Controls for CH1 & CH2 • Dual Mono mode for operating both channels with a mono signal • Bridged Mono m[...]

  • Page 5

    pm125 7 6 • 50W per channel into 8 ohms 62W per channel into 4 ohms 125W mono into 8 ohms • 1/4-inch TRS input jacks • Accepts balanced or unbalanced lines • Multi-way binding post output connectors • Independent 11 detent Level Controls for CH1 & CH2 • Dual Mono mode for operating both channels with a mono signal • Bridged Mono m[...]

  • Page 6

    Continuous Average Output Power, both channels driven: 135 watts per channel into 8 ohms from 20Hz to 20kHz, with no more than 0.1% THD 210 watts per channel into 4 ohms at 1kHz, with no more than 0.1% THD Bridged-mono operation: 420 watts into 8 ohms at 1kHz, with no more than 0.1% THD Dynamic Headroom: 1.4dB @ 4 ohms Frequency Response: 20Hz to 2[...]

  • Page 7

    Continuous Average Output Power, both channels driven: 135 watts per channel into 8 ohms from 20Hz to 20kHz, with no more than 0.1% THD 210 watts per channel into 4 ohms at 1kHz, with no more than 0.1% THD Bridged-mono operation: 420 watts into 8 ohms at 1kHz, with no more than 0.1% THD Dynamic Headroom: 1.4dB @ 4 ohms Frequency Response: 20Hz to 2[...]

  • Page 8

    5. CH1 / CH2 LEVEL CONTROLS These controls are used to adjust the input level of each channel. When the controls are fully clockwise the amplifier operates at maximum gain. T urning the controls counter-clockwise attenuates the input signal. The LEVEL controls can be bypassed by moving the jumpers located at J15 and J16, next to the LEVEL pots on t[...]

  • Page 9

    5. CH1 / CH2 LEVEL CONTROLS These controls are used to adjust the input level of each channel. When the controls are fully clockwise the amplifier operates at maximum gain. T urning the controls counter-clockwise attenuates the input signal. The LEVEL controls can be bypassed by moving the jumpers located at J15 and J16, next to the LEVEL pots on t[...]

  • Page 10

    AC Power Considerations Ensure that the pm125 or pm420 is plugged into an outlet capable of supplying the correct voltage specified for your model and enough current to allow full-power operation of all the amplifiers plugged into it. The current demand of a power amplifier varies depending on several factors, including the impedance of the load, t[...]

  • Page 11

    AC Power Considerations Ensure that the pm125 or pm420 is plugged into an outlet capable of supplying the correct voltage specified for your model and enough current to allow full-power operation of all the amplifiers plugged into it. The current demand of a power amplifier varies depending on several factors, including the impedance of the load, t[...]

  • Page 12

    CAUTION ATTENTION RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR RISK OF ELECTRIC SHOCK DO NOT OPEN TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. WARNING: 120 VAC 50-60 Hz 1000 WATTS CLASS II WIRING MAY BE USED. MADE IN U.S.A. PARALLEL LINE LEVEL INPUTS DUAL MONO NORMAL (STEREO) BRIDGED MONO OFF 0dB OFF 0d[...]

  • Page 13

    CAUTION ATTENTION RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR RISK OF ELECTRIC SHOCK DO NOT OPEN TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. WARNING: 120 VAC 50-60 Hz 1000 WATTS CLASS II WIRING MAY BE USED. MADE IN U.S.A. PARALLEL LINE LEVEL INPUTS DUAL MONO NORMAL (STEREO) BRIDGED MONO OFF 0dB OFF 0d[...]

  • Page 14

    C37 P3 P4 14 J14 P5 P6 2 1 RP2 J15 J16 RP1 J1 U5 U4 ADD THIS JUMPER TO ACTIVATE THE CH2 CLIPPING ELIMINATOR STEREO/MONO SWITCH CH2 LEVEL BYPASS CH1 LEVEL BYPASS ADD THIS JUMPER TO ACTIVATE THE CH1 CLIPPING ELIMINATOR Servicing Instructions CAUTION: T o reduce the risk of electric shock, do not perform any servicing other than that contained in the [...]

  • Page 15

    C37 P3 P4 14 J14 P5 P6 2 1 RP2 J15 J16 RP1 J1 U5 U4 ADD THIS JUMPER TO ACTIVATE THE CH2 CLIPPING ELIMINATOR STEREO/MONO SWITCH CH2 LEVEL BYPASS CH1 LEVEL BYPASS ADD THIS JUMPER TO ACTIVATE THE CH1 CLIPPING ELIMINATOR Servicing Instructions CAUTION: T o reduce the risk of electric shock, do not perform any servicing other than that contained in the [...]

  • Page 16

    C37 P3 P4 14 J14 P5 P6 2 1 RP2 J15 J16 RP1 J1 U5 U4 ADD THIS JUMPER FOR 0.775V INPUT SENSITIVITY IN CH2 ADD THIS JUMPER FOR 0.775V INPUT SENSITIVITY IN CH2 BACK OF AMPLIFIER 19 18 Figure 9 In Case of Difficul ty If you’re having trouble or suspect a problem with the pm125 / pm420, try some simple troubleshooting before contacting an Authorized Ca[...]

  • Page 17

    C37 P3 P4 14 J14 P5 P6 2 1 RP2 J15 J16 RP1 J1 U5 U4 ADD THIS JUMPER FOR 0.775V INPUT SENSITIVITY IN CH2 ADD THIS JUMPER FOR 0.775V INPUT SENSITIVITY IN CH2 BACK OF AMPLIFIER 19 18 Figure 9 In Case of Difficul ty If you’re having trouble or suspect a problem with the pm125 / pm420, try some simple troubleshooting before contacting an Authorized Ca[...]

  • Page 18

    Notes W arranty Informa tion Professional Power Amplifiers: 5 years WHA T IS COVERED: THIS W ARRANTY COVERS DEFECTS IN MATERIAL AND WORKMANSHIP ONL Y. This limited W arranty DOES NOT extend to: 1) Damage caused by shipment, 2) damage caused by accident, misuse, abuse, failure to perform owner maintenance, or operation contrary to the instructions i[...]

  • Page 19

    Notes W arranty Informa tion Professional Power Amplifiers: 5 years WHA T IS COVERED: THIS W ARRANTY COVERS DEFECTS IN MATERIAL AND WORKMANSHIP ONL Y. This limited W arranty DOES NOT extend to: 1) Damage caused by shipment, 2) damage caused by accident, misuse, abuse, failure to perform owner maintenance, or operation contrary to the instructions i[...]

  • Page 20

    DECLARATION OF CONFORMITY We PHOENIX GOLD INTERNATIONAL, INC. (supplier ’ s name) 9300 N. DECATUR, PORTLAND, OR 97203 USA (address) declare under our sole responsibility that the product pm125 / 420 (name, type or model, lot, batch or serial number, possibly sources and numbers of items) to which this declaration relates is in conformity with the[...]