Carrier 25HPA6 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Carrier 25HPA6, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Carrier 25HPA6 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Carrier 25HPA6. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Carrier 25HPA6 should contain:
- informations concerning technical data of Carrier 25HPA6
- name of the manufacturer and a year of construction of the Carrier 25HPA6 item
- rules of operation, control and maintenance of the Carrier 25HPA6 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Carrier 25HPA6 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Carrier 25HPA6, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Carrier service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Carrier 25HPA6.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Carrier 25HPA6 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    25HP A6 Performa nce t Series 2 - - - Stag e Heat Pump with P u ron r Re fri gera nt 2t o5N o m i n a lT o n s Installation Instruction NOTE : Read the en tire in structio n m an ual b efore startin g the installatio n . SAFETY CONSIDERA TIONS Imp rop er installatio n , ad ju stmen t, alteration , service, m ainten an ce, or use ca n ca us e expl o[...]

  • Page 2

    2 INST ALLA TION RECOMMENDA TIONS NOTE : In som e cases no ise in the liv in g area has been traced to gas pul sa ti ons from i mpr oper i nst al lat ion of equipm ent. 1. Loca te unit awa y from windows , pati os, de cks , et c. whe re unit ope rat ion sound m a y dis turb c ust ome r . 2. Ensure t hat va por and liqui d t ube diam et er s are a p[...]

  • Page 3

    3 Op eratin g Amb ien t The mini mum out door opera ting a mbie nt i n cool ing mode i s 55 _ F (12. 78 _ C) without l ow ambi ent c ooling e nabl ed, a nd the ma xim um out door ope ra ti ng ambi ent i n cooli ng mode is 125 _ F (51. 67 _ C). At l ine volt age of 208v (or bel ow) and an outdoor am bie nt of 120 _ F (48. 9 _ C) (a nd above ), the c[...]

  • Page 4

    4 T able 1 – Re fri ger ant Conne cti ons and Rec ommende d Liquid and V apor T ube Di amet er s (i n.) UNI T SIZE LIQUID RATED V APOR* Connect ion Diameter Tu b e Diameter Connect ion Diameter Tu b e Diameter 25HP A624 3/8 3/8 3/4 3/4 25HP A636 3/8 3/8 7/8 7/8 25HP A648 3/8 3/8 7/8 1 --- 1 / 8 25HP A660 3/8 3/8 7/8 1 --- 1 / 8 * Un its are rated[...]

  • Page 5

    5 In stall Liq uid- - Line Filt er Drier Indoor Refer to Fig . 3 an d in stall filter d rier as follo ws: 1. Braz e 5 - - in. ( 127 mm) li quid tube t o t he indoor c oil. 2. Wrap filter drier with dam p clo th. 3. B raze filter d rier to a bove 5 - - in. (127 mm) l iquid tube . Flow ar row must poi nt towa rds indoor c oil. 4. C o nn ect an d b ra[...]

  • Page 6

    6 NOTE : Op eration o f un it o n imp ro per line v oltag e co nstitu tes abu se and co uld affect unit r eliability. See un it ratin g p late. Do n ot ins ta ll uni t in syst em wher e volta ge may fl uctua te above or be low perm issible lim its. NOTE : Us e copper wir e only be twe en dis conne ct s wit ch and uni t. NOTE : I nst all br anc h ci[...]

  • Page 7

    7 Airf low Selec tion f or FV4C Fan Coils Using Non - - Commun ica tin g (Non - - In fin ity) T h ermostats The FV4C provi des high- - a nd low- - st age bl ower oper at ion to match th e cap acities of co mp resso r at h ig h - - and low - - stag e. T o select recomm end ed airflow, refer to FV4 C Installation Instru ctio ns. Th e FV4 C u tilizes [...]

  • Page 8

    8 Ti m e Delays The unit t ime del ays i ncl ude: S Fiv e minu te time delay to start coolin g o r h eatin g op eratio n wh en there is a call fro m the th ermo stat o r user interface. T o bypas s thi s fe at ure , moment ari ly shor t and re lea se For ced De fr ost pi ns. S Five m inut e compr es sor r e- - cyc le de la y on ret urn from a brown[...]

  • Page 9

    9 GENE RAL INFORMA TI ON Infi nity Co ntroll ed l ow a mbie nt cool ing: This unit i s c apabl e of low a mbie nt cool ing down t o 0 ° F (- - 17.8 ° C) wit hout a kit ONL Y when using an Infi nity Control . A low am bie nt ki t is not requi re d for I nfini ty c ontr olle d low a mbie nt oper at ion. The I nfini ty Control provi des a n aut omat[...]

  • Page 10

    10 output i s provide d at t he Y1 connec ti on. Connec t the sole noid as show n in t he wi ri ng la bel diagr am. This is a 24vac output tha t is energized w h enev er th e com presso r is en ergized. It clo ses, in th e com pre ss or off m ode, to pre vent re fri gera nt migr ati on into the unit thr ough the l iqui d - - li ne. On S ystem s wit[...]

  • Page 11

    11 NOTE : The m odel pl ug take s pr ior ity ove r f act ory mode l inf orma tion input a t the fa ctor y . I f the model pl ug is re moved a ft er initial p o wer u p, the u ni t w ill op erate acco rd ing t o the last v alid mode l pl ug inst al le d, a nd fl as h the appropr ia te fa ult code temp orarily. Pres sur e Sw itch Protect ion The out [...]

  • Page 12

    12 2. If the e xpect ed re sul t is not ac hie ved, re move the s ole noid plug f rom t he c ompre ss or a nd wit h the unit running a nd the User In terface or th erm ostat calling fo r hig h stag e, test th e volt age output a t the plug wit h a DC vol tme ter . The re ad- ing s hould be 24 volt s DC. 3. If the co rrect DC vo ltage is at the cont[...]

  • Page 13

    13 Stat us Codes T abl e 4 shows the s ta tus code s fla she d by the a mber s ta tus li ght. Mos t sys tem proble ms c an be di agnos ed by re adi ng t he s ta tus code as fl a she d by the ambe r s ta tus light on the contr ol boa rd. The code s ar e fl as hed by a ser ie s of shor t and long fl as hes of the status lig h t. T he sh ort flashes i[...]

  • Page 14

    14 RVS/Heat Stage 2 O/B W 2 Heat Stage 1 W /W 1 Compressor Low Y1 Compressor High Y/Y2 Fan G 24VAC Hot Heating Rh 24VAC Hot Cooling Rc Dry Contact 1 D1 Dry Contact 2 D2 24VAC Comm on C Humidify HUM Outdoor Air Temp OAT Remote Room Sensor RRS OAT/RRS Com OAT/RRS Outdoor Sensor * Humidifier Solenoid Valve * Remote Room Sensor * O Y1 W1 G W2 C Y2 R W1[...]

  • Page 15

    15 FINAL CHECKS IMPOR T ANT : Be fore l eavi ng job, be s ure to do the f ollow ing: 1. E n sure that all wiring is rou ted aw ay from tub in g and sheet me ta l edge s to preve nt rub- - thr ough or wir e pinc hing. 2. Ensur e that a ll wiri ng and tubing is se cure i n unit bef ore add in g pan els and co vers. Secu rely fasten all pan els and co[...]

  • Page 16

    16 Copyright 2009 Carrier Corp. S 7310 W . Mo rr is St. S In dia napolis, I N 46231 Print ed in U.S .A. Edition Date: 05/09 Manufacturer reser ves the right to change , at any time, specifications and designs without notice and without obligations. Catal og N o: 25HP A6 - - - 1SI Replaces : New 25HP A6[...]