Campbell Manufacturing CS510 manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Campbell Manufacturing CS510, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Campbell Manufacturing CS510 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Campbell Manufacturing CS510. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Campbell Manufacturing CS510 should contain:
- informations concerning technical data of Campbell Manufacturing CS510
- name of the manufacturer and a year of construction of the Campbell Manufacturing CS510 item
- rules of operation, control and maintenance of the Campbell Manufacturing CS510 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Campbell Manufacturing CS510 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Campbell Manufacturing CS510, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Campbell Manufacturing service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Campbell Manufacturing CS510.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Campbell Manufacturing CS510 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    CS510 OXYGUARD DISSOLVED OXYGEN PROBE INSTRUCTION MANUAL 1/00 COPYRIGHT (c) 2000 CAMPBELL SCIENTIFIC, INC.[...]

  • Page 2

    This is a blank page.[...]

  • Page 3

    The CS510-L Oxyguard Dissolved Oxygen Probe is manufactured by Point Four Systems Incorporated. Point Four’s conditions of sale and return policy apply to these items. Products may not be returned without prior authorization. To obtain an RMA number contact Point Four Systems, Inc., phone (604) 936-9936. NOTE: if the product has been exposed to h[...]

  • Page 4

    This is a blank page.[...]

  • Page 5

    1 CS510 OxyGuard Dissolved Oxygen Probe An accurate and reliable sensor is a critical element in any measurement system. The OxyGuard Stationary Probe meets these criteria for the measurement of dissolved oxygen. 1. General Information The OxyGuar d Stationary Probe is a galv anic prob e which pro duces a millivo lt signal proporti onal t o the amo[...]

  • Page 6

    CS510 OxyGuard Dissolved Oxygen Probe 2 2. Specifications Principle of Measurement: Membrane covered polarographic oxygen probe — self polarizing galvanic cell Output Si gnal: 5 mV per mg/ l, 2 mV per % /vol nomi nal Accuracy: Better than +/- 2 % of reading +/- 1 digit when calibration temperature equals measuring temperature +/- 5 C Repeatabilit[...]

  • Page 7

    CS510 OxyGuard Dissolved Oxygen Probe 3 3. Service Kit Spare membr ane cap with fitted membran e. 50 ml electrolyte. Spare anode and O-ring. FIGURE 3-1. Exploded View of CS510-L 4. Optional Probe Accessories Agitator for s t agnant condi t ions . Probe Mou nting assem bly for waste water installation s. Flow-through and by-pass fittings. EasyCal ca[...]

  • Page 8

    CS510 OxyGuard Dissolved Oxygen Probe 4 FIGURE 5-1. Preventing Bio-fouling of the CS510-L The PT4 Agitator overcomes thes e problems . The devi ce is des i gned so t hat a soft brist le brus h sw eeps across t he probe membrane or se ns or ti p. This s weepi ng action of the brush provi des t he required w ate r veloci ty as wel l as prevent s the [...]

  • Page 9

    CS510 OxyGuard Dissolved Oxygen Probe 5 Optional Rep eat Cycle Timer fo r Agitators : Reciprocating action may be controlled by the opt ional sol id s t ate R epeat C ycle Ti mer. It s ends 12 V DC puls e s to the agitator coil. The ON-time is 0. 25 sec. The OFF-time is ad justable fro m 3 to 12 sec.; requires s uppl y vol tage 10 t o 17 VD C ; hou[...]

  • Page 10

    CS510 OxyGuard Dissolved Oxygen Probe 6 3) Determine the air temperature and barometric pressure. 4) Usi ng a cali brati on chart s uch as that provided i n the probe ’ s manual, determine the oxygen concentrati on of the air. 5) Use the followin g equatio n to calculate the m ultiplier: M = P/R M = Multiplier P = Concentrati on in P PM of t he a[...]

  • Page 11

    CS510 OxyGuard Dissolved Oxygen Probe 7 The following instructions in program table 2 would trigger the agitator as discussed in the agitator manual: *Table 2 Program 02: 2.0 Execution Interval (seconds) 1: Do (P86) 1: 41 Set Port 1 High ; Use port number as wired 2: Excitation with Delay (P22) 1: 1 Ex Channel 2: 0 Delay W/Ex (units = 0.01 sec) 3: [...]

  • Page 12

    CS510 OxyGuard Dissolved Oxygen Probe 8 This is a blank page.[...]