Bunn JDF-4S manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Bunn JDF-4S, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bunn JDF-4S one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Bunn JDF-4S. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Bunn JDF-4S should contain:
- informations concerning technical data of Bunn JDF-4S
- name of the manufacturer and a year of construction of the Bunn JDF-4S item
- rules of operation, control and maintenance of the Bunn JDF-4S item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bunn JDF-4S alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bunn JDF-4S, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bunn service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bunn JDF-4S.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Bunn JDF-4S item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    JDF-2S JDF-4S Silver Series® INST ALLA TION & OPERA TING GUIDE BUNN-O-MA TIC CORPORA TION POST OFFICE BO X 3227 SPRINGFIELD , ILLINOIS 62708-3227 PHONE: (217) 529-6601 F AX: (217) 529-6644 T o ensure you have the latest revision of the Operating Manual, or to view the Illustrated Parts Catalog, Programming Manual, or Service Manual, please vis[...]

  • Page 2

    2 44744 051910 BUNN-O-MA TIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) All equipment other than as specified below: 2 years parts and 1 year labor . 2) Electronic circuit and/or control boards: parts and labor for 3 years. 3) Compressors on refrigeration equipment: 5 years part[...]

  • Page 3

    3 USER NOTICES Carefully read and follow all notices on the equipment and in this manual. They were written for your protec- tion. All notices are to be kept in good condition. Replace any unreadable or damaged labels. 27442.7000 00986.7000 33461.0001 JDF-2S W ARNING F AILURE TO COMPL Y RISKS EQUIPMENT DAMAGE, FIRE OR SHOCK HAZARD. READ THE ENT IRE[...]

  • Page 4

    4 PLUMBING REQUIREMENTS This dispenser must be connected to a COLD WA TER system with operating pressure between 20 and 100 psi (138 and 690 kPa). This water sour ce must be capable of producing a minimum flow rate of 3 fluid ounces (88.7 milliliters) per second. A shut off valve should be installed in the line before the dispenser . Install a re[...]

  • Page 5

    5 2. On Portion Control models, connect membrane switches to Door Circuit Board. 4. Secure the door cover using 5 screws provided. DOOR COVER INST ALLA TION 1. Install door cover by first plugging the door harness connector into the machine harness connector located at the bottom of the machine door . P3577 P3579 JDF-2S JDF-4S Shown JDF-2S JDF-4S [...]

  • Page 6

    6 INITIAL FILL CAUTION: The dispenser must be disconnected from the power source throughout the initial fill except when specified in the instructions. 1. Remove drip tray assembly and splash panel from the dispenser . Replace the drip tray . 2. Connect the water source to the back of the dispenser . 3. Pull the fill tube from the dispenser , re[...]

  • Page 7

    7 FIG 5 Initial Fill Connection - JDF-2S P3582 7. T urn ON the refrigeration switch near the main control board. This will start the water bath pump circulation. 8. Check water level in the overflow tube and top off the tank if necessary (Step 5). 9. Disconnect the fill tube and allow excess water to drain into the drip tray . Replace the plug in[...]

  • Page 8

    8 PRIMING 1. Open the dispenser door 2. Load concentrate per instructions in section titled Loading . 3. Close the dispenser door . 4. Place a large container under the appropriate dispense nozzle. Press and hold the “Product Dispense Switch” Fig 5, until concentrate dispenses from the dispense nozzle. Note: This may take several seconds, depen[...]

  • Page 9

    9 FIG 11 Product Dispense Switches - JDF-2S Product Dispense Switch (Membrane Switch Machines) A. Product Dispense Switch Momentarily pressing and releasing one of the switches will initiate a timed dispense. Each station has three different timed dispenses which are preset at the factor y . Refer to DISPENSER USE section for preset volumes and adj[...]

  • Page 10

    10 OPERA TING CONTROLS (Continued) Portion Control Option (Mechanical Switch Machines) The dispenser is also equipped with a portion control option. The following steps will guide you through the set up process for this option. Portion control can be set on one or all dispense heads as needed. 1. Unplug dispenser from power source. 2. Set the Progr[...]

  • Page 11

    11 P3585 FIG 15 T emperature LEDs JDF-2S (Early Models) FIG 16 T emperature LEDs JDF-4S P3845 OPERA TING CONTROLS (Continued) FIG 15A T emperature LEDs JDF-2S (Late Models) Procedure to return all dispense heads back to Push and Hold mode (Mechanical Switch Machines): 1. Unplug dispenser from power source. 2. Place Program switch in the ON position[...]

  • Page 12

    12 CLEANING & PREVENTIVE MAINTENANCE Daily: Rinse Procedure T ools required: 32 oz. (946 ml) minimum empty container 1. Open dispenser door . Lift up on product containers and remove them from the machine. 2. Close the door , place an empty container under the dispensing nozzle. 3. Dispense from each station until clear water flows from the di[...]

  • Page 13

    13 CLEANING (cont) Monthly: Clean Condenser Coils 1. Use a soft bristle brush to clean the build up of dirt in the condenser . NOTE: Some models include a removable filter that can be cleaned in warm soapy water . Annually: Replace Pump T ubing 1. Open dispenser door . 2. Remove all product containers and place them in a refrigerated (35-40 degree[...]

  • Page 14

    14 FIG 17 Adjusting Water Flow Using 1/4" allen wrench Mix Ratio Adjust water flow rate to: Product Brix % (water + concentrate) 2+1 *3.75 fl. oz (111 ml) Prune Juice 16.0% per 3-second test Other * Orange Juice 11.8% 4+1 Pineapple Juice 12.8% Cranberry Fruit Cocktail 14.0% *4.0 fl. oz (118 ml) Grapefruit Juice 10.6% per 3-second test Lemon[...]

  • Page 15

    15 T otal Dispense Ratio Set Up Procedure 1. Adjust water flow as described in Water Flow T esting and Adjustment . Record water output setting for later reference on each dispense head. 2. Place the Program switch in the ON position. 3. Place a measuring container under the dispense nozzle, press and release the DISPENSE button 6 times. 4. Record[...]

  • Page 16

    16 ADJUSTMENT & OPTIONAL SETTINGS (cont) Dispenser Lockout Dispense functions of the dispenser can be turned-off to prevent unauthorized use of the dispenser , while keeping the refrigeration system running. 1. Locate the Dispense Lockout switch at the bottom front of the dispenser behind the drip tray . 2. Place the switch in the OFF position [...]

  • Page 17

    17 Circuit Board LED Indicators - JDF-2S (Early Models) LED # LED Color Illuminates: 1 Green When the compressor should be ON. 2 Cabinet Red When the cabinet temperature is above 50 degrees F . Flashes slowly when cabinet temperature exceeds 50 degrees F for 4 hours. Dispense functions are locked out under this condition. Power down the dispenser t[...]

  • Page 18

    18 FIG 19 JDF-4S FUNCTION LIST (Continued) 3 1 2 4 5 P3845 Circuit Board LED Indicators - JDF-4S and Late Model JDF-2S LED # LED Color Illuminates: 1 Bath Red When bath temperature is above 34 degrees F . Flashes slowly when compressor is in a 6 minute delay period. Open bath thermistor circuit will flash #1 and #2 LED’ s 1 time ever y 3 seconds[...]

  • Page 19

    19 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic T echnical Ser vice Department. • Inspection, testing, and repair of electrical equipment should be per formed only by [...]

  • Page 20

    20 TROUBLESHOOTING (cont.) Check for "ON" position or no con- tinuity - replace switch. Clean filter and fins or replace con- denser filter . (Filter not supplied on some machines). A) Check for 120V or 230V AC. Re- place fan motor or check fan blades for obstructions. B) Check compre ssor LED on circu it board. If ON, relay coil shoul[...]

  • Page 21

    21 TROUBLESHOOTING (cont.) Dispense station not working All stations dispense concentrate only 1. Dispense Lockout switch set to OFF position. 2. Dispense switch failed Main water supply Frozen bath Inlet water valve failed Place switch in ON position. Che ck sw itc h and ha rne ss for prope r continuity . Check for ON position. A) Compressor relay[...]

  • Page 22

    22 TROUBLESHOOTING (cont.) Dispense station concentrate only Dispense station water only Replace solenoid (24vdc) or check wire connection between water valve and main control board. Replace refill concentrate container or BIB Check for proper counterclockwise rotation of pump rollers. If coun- terclockwise, replace pump tubing. If clockwise, wire[...]

  • Page 23

    23 TROUBLESHOOTING (cont.) Water leak filling drip tray or around dispense deck area Water leaking beneath machine Erratic spray during dispense Dispense nozzle dripping water 1. Initial fill/setup 2. Dispense deck 3. W ater pressure greater than 100psi 1. Bath tank overflow . 2. Condensation from cabinet cool- ing coil. Dispense nozzle mixer mi[...]

  • Page 24

    24 TROUBLESHOOTING (cont.) Unit is not working Difficulty brixing and/or weak bev- erage Difficulty brixing and/or weak bev- erage Difficulty brixing bag-in-box 1. Step-down transformer . 2. Main control board. 1. Product viscosity or too cold. 2. Low water pressure. 3. High water pressure. 4. Dispense valve adjustment set- ting. 5. Brix ratio. [...]

  • Page 25

    25 COOLANT SCHEMA TIC DIAGRAM CONDENSER SUCTION ACCUMULA TOR COMPRESSOR EV APORA TOR PROCESS TUBE FIL TER DRYER 44744 032811[...]

  • Page 26

    26 J6-1 J11-1 J11-5 J6-1 J6-5 J6-3 J5-1 J5-4 J2-1 J2-6 GRN WHI/ORN LEFT DISPENSE RIGHT DISPENSE LEFT DISPENSE RIGHT DISPENSE YEL YEL WH I/ VI O RECIR. PUMP BRN WHI BLK J1-1 J1-5 WHI J3-1 J3-2 WHI/BLK ORN WHI/VIO WHI/ORN VIO RED RED RED WHI/RED BLK WHI RED/BLK RED/BLK YEL WHI/BLU BLU BLK RED BLU YEL YEL BRN BRN ORN RED MOTOR CONDENSOR FAN RED/BLK BL[...]

  • Page 27

    27 J6-1 J6-3 J5-1 J5-4 J2-1 J2-6 GRN WHI/ORN STA TION 1 DISPENSE STA TION 2 DISPENSE STA TION 1 DISPENSE STA TION 2 DISPENSE YEL YEL WH I/ VI O RECIR. PUMP BRN WHI BLK J1-1 J1-5 WHI J3-1 J3-2 WHI/BLK ORN WHI/VIO WHI/ORN VIO RED RED WHI/RED BLK WHI RED/BLK YEL WHI/BLU BLU RED MOTOR CONDENSOR FAN RED/BLK BLU/BLK BLU/BLK J7-1 J7-2 J9-1 J9-2 PUMP PUMP [...]

  • Page 28

    28 1. Install door cover by first plugging the door harness connector into the machine harness connector located at the bottom of the machine door . 2. Install door cover . 3. Secure the door cover using 5 screws provided. 4. Place refrigeration switch in the OFF po- sition. 5. Connect water supply to machine. (See Plumbing Requirements) 6. Connec[...]