Bryant CK5A manual

1
2
3
4
5
6
7
8

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Bryant CK5A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bryant CK5A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Bryant CK5A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Bryant CK5A should contain:
- informations concerning technical data of Bryant CK5A
- name of the manufacturer and a year of construction of the Bryant CK5A item
- rules of operation, control and maintenance of the Bryant CK5A item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bryant CK5A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bryant CK5A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bryant service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bryant CK5A.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Bryant CK5A item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Form No. PDS CK5A.18.1 FURNACE N-COILS CK5A, CK5B Sizes A018 thru A060 This vertical design N-coil is a furnace coil designed to provide the highest standards of reliability and durability. The product is offered in a painted cased (CK5A) or an embossed cased (CK5B) version. The cased coils are offered in standard, over- hang, and wide configuratio[...]

  • Page 2

    —2— MODEL NUMBER NOMENCLATURE CK 5 C—Coil K—Cased, N-Coil 5—Upflow/Downflow CERTIFICATION APPLIES ONLY WHEN USED WITH PROPER COMPONENTS AS LISTED WITH ARI AXA 0 1 8 018—1-1/2 Ton 024—2 Ton 030—2-1/2 Ton Etc. 014—14-3/16 in. 017—17-1/2 in. 021—21 in. 024—24 1/2 in. A — Standard N — Narrow T — Transition W — Wide X —[...]

  • Page 3

    —3— A97606 DIMENSIONS (In.) * In these models the coil can be removed from the casing and installed as an uncased coil without needing to field fabricate the coil enclosure to prevent air bypass. UNIT SERIES A B C D E F G SHIPPING WEIGHT (LB) CK5(A,B)XA018014* A 14-3/16 13-1/4 12-9/16 5 5/8 2-1/8 1-3/8 28-1/2 CK5(A,B)XA024014* A 14-3/16 13-1/4 [...]

  • Page 4

    —4— GROSS COOLING CAPACITIES (MBH) CFM — Cubic Ft per Minute EWB — Entering Wet Bulb (°F) TC — Gross Cooling Capacity 1000 Btuh SHC — Gross Sensible Capacity 1000 Btuh BF — Bypass Factor MBH — 1000 Btuh UNIT SIZE INDOOR COIL AIR SATURATED TEMPERATURE LEAVING EVAPORATOR (°F) 30 35 40 45 50 CFM EWB TC SHC BF TC SHC BF TC SHC BF TC S[...]

  • Page 5

    —5— GROSS COOLING CAPACITIES (MBH) Continued CFM — Cubic Ft per Minute EWB — Entering Wet Bulb (°F) LWB — Leaving Wet Bulb (°F) TC — Total Cooling Capacity 1000 Btuh SHC — Total Sensible Capacity 1000 Btuh BF — Bypass Factor MBH —1000 Btuh NO TES: 1. Contact manuf acturer for cooling capacities at conditions other than shown in [...]

  • Page 6

    —6— COIL STATIC PRESSURE DROP (In. WC) INDOOR COIL PISTONS UNIT SIZE BULB AIR QUANTITY (CFM) A018 400 500 600 700 800 — WET 0.08 0.12 0.16 0.22 0.29 — DRY 0.07 0.11 0.15 0.20 0.27 — A024 600 700 800 900 — — WET 0.16 0.21 0.26 0.31 — — DRY 0.14 0.19 0.24 0.29 — — W024 600 700 800 900 — — WET 0.15 0.20 0.24 0.30 — — DRY [...]

  • Page 7

    —7—[...]

  • Page 8

    SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Cancels: PDS CJ5A.18.3 © 1999 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indpls, IN 46231 —8— PRINTED IN U.S.A. Catalog No. 12CK-5A1 4-99 SERVICE TRAINING Packaged Service Training programs are an excellent way to i[...]