A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Bryant 180A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bryant 180A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Bryant 180A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Bryant 180A should contain:
- informations concerning technical data of Bryant 180A
- name of the manufacturer and a year of construction of the Bryant 180A item
- rules of operation, control and maintenance of the Bryant 180A item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bryant 180A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bryant 180A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bryant service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bryant 180A.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Bryant 180A item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    180A, 187A Evolution r Line Air C onditioners with P uron Refrigerant 2 to 5 Nominal T ons (Sizes 024 to 060) Installation Instructions NOTE : Read the en tire in structio n m anu al b efore startin g the installatio n . Un less otherw ise noted , info rmatio n in th ese installatio n ins t ruc t ions per t ai n t o both 180A and 187A se r ie s uni[...]

  • Page 2

    2 INST ALLA TION RECOMMENDA TIONS NOTE : In som e cases noi se in the liv in g area has been traced to gas pul sat i ons fr om impr ope r ins ta lla t ion of equi pme nt. 1. Locat e unit awa y from windows , pat ios , de cks , et c. whe re unit oper a ti on s ound ma y dis t urb c us tome r . 2. Ensure t ha t vapor and li quid tube di am et e rs ar[...]

  • Page 3

    3 On roof top appl i ca t ions , loca te uni t at l eas t 6 i n. (152.4 mm ) a bove roo f su rface. Op eratin g Amb ien t The mi nimum outdoor oper a ti ng ambi ent in cool ing mode is 55 _ F/12. 78 _ C wi t hout low a mbi ent c ool ing e na ble d, a nd the ma ximum out door ope r at i ng ambi ent i n c ooli ng mode is 125 _ F/51. 67 _ C. On Evolut[...]

  • Page 4

    4 T a ble 2 – Accesso ry U sag e Accessory REQUIRED F OR L O W --- A M B I E N T C O O L I N G APPLICA TION S (Below 5 5 ° F/12.8 _ C) REQUIRED FOR LON G LINE APPLICA TION S* REQUIRED FOR SEA COAST APPLICA TION S (W ithi n 2 mile s /3.22 km) Accumu lator No No No Compressor Star t Assist Capacitor a nd Relay } Standard on 187A models. Not requir[...]

  • Page 5

    5 Ref rige ra nt tubes a nd indoor coi l shoul d be evac uate d using the re comme nde d dee p va cuum met hod of 500 mic rons. The al ter na te triple ev acu ation metho d m ay b e u sed. S ee Serv ice Manu al for tr i ple evac uati on me thod. Alw ays br ea k a vac uum wi t h dr y nit r ogen. _ Deep V acuu m Method The de ep vac uum met hod re qu[...]

  • Page 6

    6 Mak e Airflo w Sel ectio ns Airflow Setup for Evol ution Contr ol Furnace of FE Fan coil (communicating) When us ing an Evo lution U ser Interface, airflow is automatically s elected bas ed on equip ment size. See U ser Interf ace Ins tallation In stru ctions for availab le adjus tments . Airflo w Select ion for V ariab le Speed Fu rnaces for Mo [...]

  • Page 7

    7 Syst e m Func tio ns And Seque nce Of O per at ion The outdoor unit cont r ol s yste m ha s s peci al func t ions . The fol l owing is a n over vie w of the 2- - sta ge contr ol f unct i ons: Coo ling Op eratio n 187A a nd 180A (c ontai ni ng ci r cui t boa rd HK38EA015 or ne we r) mo dels utilize eith er a 2- - stag e coolin g i ndoor the rmos t[...]

  • Page 8

    8 Compr essor Operati on on 180A Mod els Th e b asic scroll d esign h as been m o dified with the ad ditio n o f an int e rna l unl oadi ng mec ha nis m tha t opens a by- - pas s port i n the fir s t com pressio n p ock et, ef fectively red u cing th e d isp lacemen t of th e sc roll . The opening and cl osing of the by - - pas s port is c ontrol l[...]

  • Page 9

    9 Check Ch arge All 180A and 187A uni ts mus t be char ge d in hi gh s tage only . Fac tory c ha r ge am ount a nd de si r ed subc ool ing a re shown on unit rating p late. Chargin g meth o d is sho w n on info rmatio n plate insid e unit . T o prope rl y chec k or adj us t cha r ge, c ondit ions mus t be fa vorabl e for s ubcooli ng cha r ging. Fa[...]

  • Page 10

    10 The cont r ol is s hippe d wit h the br ownout a ct ive . The cha nge in st a tus is rem embe red unt il t oggle d to a ne w s ta tus. A pow er down/pow er up se quenc e wil l not res e t the s tat us . It ma y be nec ess ary t o do t he t oggl e t wi ce to cyc le t o the des ir e d st a te of the defeat. 230V Line (Power Disconn ect) Detectio n[...]

  • Page 11

    11 T a b l e5–2 - - - S t a g eC o m p r e s s o r (W inding Resist ance at 7 0 _ F ± 20 _ / 21.11 _ C ± 11.11 _ C) Winding 187A024 187A036 187A048 187A060 S t a r t ( S --- C ) 2.74 1.98 1.55 0.74 Run (R - - - C) 0.80 0.75 0.48 0.36 Winding 180A024 180A 036 180A048 180A060 S t a r t ( S --- C ) 1.40 1.29 1.52 0.60 R u n ( R --- C ) 1.32 0.89 0[...]

  • Page 12

    12 OAT T herm istor must be locked in plac e wi th sp heric al nib end fac ing to - ward s the front of the co ntro l bo x Fig. 8 - - Outdoor Air The r mis t or (OA T) Attac hment OCT Therm istor must be secured tight on the liquid tube . Fig. 9 - - Outdoor Coi l Ther mi st or (O CT) Att ac hment FINAL CHECKS IMPOR T ANT : Be for e le aving job, be[...]

  • Page 13

    13 Stat us Codes T a ble 6 shows t he sta tus code s f la s hed by the a mber s ta tus li ght. Mos t s yste m pr oble ms c an be dia gnosed by r eadi ng the st at us c ode as fl ashe d by the a mbe r st at us li ght on t he cont rol boar d. The code s are f l as he d by a se ri es of shor t and long f las he s of t he status lig h t. Th e sh ort fl[...]

  • Page 14

    14 A08057 T h e r m i d i s t a t M o d e l s T 6 --- P R H --- 0 1 & T 6 --- N R H --- 0 1 w/ Fur n ace & 2 - - - Sta ge Air C on ditio n er RVS/Heat Stage 2 O/W2/B W 2 Heat Stage 1 W /W1 W 1 Compressor Low Y1 Y1 Y1 Com pre ssor High Y/Y2 Y/ Y2 Y2 Fan G G 24VAC Hot Heating Rh R R 24VAC Hot Cooling Rc Dry Contact 1 D1 Dry Contact 2 D2 DHUM [...]

  • Page 15

    15 D C B A User Interface D C B A D C B A F an Coil Communicating AC//H P OA T R Y O W C HUM C Humidifier 24vac A03076 Fig. 1 1 - - Evolut ion Furnac e or Fan Coil W i ri ng with Communi c ati ng 2 - - stage A C PURON R (R- - 410A) REFRIGERANT QUICK REFERENCE GUIDE S Pu ro n refrig eran t op erates at 50 - - 7 0 p ercent h ig her p ressu res than R[...]

  • Page 16

    16 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. E 2009 Bryan t Heating & Cooling S yst ems D 7310 W . Morris St. D I ndianapolis, I N 46231 Print ed in U.S. A. Edition Date: 07/09 Replaces : II 180A - - - 05 Catal og N o. II180 A --- 0 6 180A /[...]