The rules should oblige the seller to give the purchaser an operating instrucion of Bradley Smoker MG-2/BIR3, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bradley Smoker MG-2/BIR3 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Bradley Smoker MG-2/BIR3. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Bradley Smoker MG-2/BIR3 should contain:
- informations concerning technical data of Bradley Smoker MG-2/BIR3
- name of the manufacturer and a year of construction of the Bradley Smoker MG-2/BIR3 item
- rules of operation, control and maintenance of the Bradley Smoker MG-2/BIR3 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bradley Smoker MG-2/BIR3 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bradley Smoker MG-2/BIR3, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bradley Smoker service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bradley Smoker MG-2/BIR3.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Bradley Smoker MG-2/BIR3 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    MG-2/BIR3 Express® Lavatory System - MG Series with Battery Infrared Control Inst allation Instructions P .O. Box 309, Menomonee Falls, WI 53052-0309 TEL. 1-800-BRADLEY F AX 262-251-5817 http://www .bradleycorp.com T able of Content s Pre-Installation Information . . . . . . . . . . . . . . . . . .2 Dimensions . . . . . . . . . . . . . . . . . . .[...]

  • Page 2

    Express® Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation Instructions 2 8/23/07 Bradley Corporation • 215-1510 Rev . D; ECN 07-815 Pre-Inst allation Information Barrier-free and ADA compliant - st andard height mounting The MG-2/BIR3 Express® Lavatory System with Battery Infrared Control must have a rim height n[...]

  • Page 3

    3 Express® Lavatory System - MG Series with Battery Infrared Control Installation Instructions MG-2/BIR3 Bradley Corporation • 215-1510 Rev . D; ECN 07-815 8/23/07 MG-2/BIR3 Express® Lavatory System Dimensions 27" (686) 47" (1 194) 54" (1372) 42" (1067) 15" (381) *Subtract 4" from vertical dimensions for compliance[...]

  • Page 4

    Express® Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation Instructions 4 8/23/07 Bradley Corporation • 215-1510 Rev . D; ECN 07-815 Dimensions continued . . . T AS Juvenile Height Grades 6 thru 8 or 9 T AS Juvenile Height Grades Pre-K thru 5 or 6 35-1/2" (902) 30" (762) 26" (660) 14" (356) 37-1[...]

  • Page 5

    5 Express® Lavatory System - MG Series with Battery Infrared Control Installation Instructions MG-2/BIR3 Bradley Corporation • 215-1510 Rev . D; ECN 07-815 8/23/07 Inst allation Instructions Step 1: Rough in supplies and optional hot water heater NOTE: See Figur e 1 (below), 1a, 1b (for T AS on page 6) and Figur e 2 (on page 7) when r oughing in[...]

  • Page 6

    Express® Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation Instructions 6 8/23/07 Bradley Corporation • 215-1510 Rev . D; ECN 07-815 Figure 1a T AS - T exas Accessibility St andards: Juvenile Height (grades Pre-K thru 5 or 6) 4" (102 ) FLOOR APPROX. DIMENSION 14" (356) 14" (356 ) 24-3/4" (629 ) [...]

  • Page 7

    7 Express® Lavatory System - MG Series with Battery Infrared Control Installation Instructions MG-2/BIR3 Bradley Corporation • 215-1510 Rev . D; ECN 07-815 8/23/07 Inst allation Instructions continued . . . Step 2: Rough in wall anchors 1. Install six 3/8" wall anchors with a minimum pull-out rating of 1,000 lbs. (supplied by installer) at [...]

  • Page 8

    Express® Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation Instructions 8 8/23/07 Bradley Corporation • 215-1510 Rev . D; ECN 07-815 Inst allation Instructions continued . . . Step 3: Mount frame to wall 1. Loosen, but do not remove the bottom three access panel screws. 2. Remove the two top access panel screws and[...]

  • Page 9

    9 Express® Lavatory System - MG Series with Battery Infrared Control Installation Instructions MG-2/BIR3 Bradley Corporation • 215-1510 Rev . D; ECN 07-815 8/23/07 Inst allation Instructions continued . . . Step 4: Inst all bowl assembly IMPORT ANT : See Figure 4 below when inst alling the bowl assembly . If the fixture has soap option, refer to[...]

  • Page 10

    Express® Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation Instructions 10 8/23/07 Bradley Corporation • 215-1510 Rev . D; ECN 07-815 Inst allation Instructions continued . . . Step 5: Connecting supply 1. Loosen but do not remove the two mounting screws holding the valve bracket to the frame. Slide the valve brack[...]

  • Page 11

    11 Express® Lavatory System - MG Series with Battery Infrared Control Installation Instructions MG-2/BIR3 Bradley Corporation • 215-1510 Rev . D; ECN 07-815 8/23/07 Inst allation Instructions continued . . . Step 7: Connecting electrical and supply tubing W ARNING: The MG-2/BIR3 must be connected to the 6 VDC battery . Connection to 1 10 V AC ma[...]

  • Page 12

    Express® Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation Instructions 12 8/23/07 Bradley Corporation • 215-1510 Rev . D; ECN 07-815 Cleaning and Maintenance Instructions IMPORT ANT : Strong alkaline or acid-based chemicals and cleansers should not be used to clean the MG-2/BIR3 Express®. If these chemicals come [...]

  • Page 13

    13 Express® Lavatory System - MG Series with Battery Infrared Control Installation Instructions MG-2/BIR3 Bradley Corporation • 215-1510 Rev . D; ECN 07-815 8/23/07 Assembly of Component s SPRA YHEAD BODY (P ART NUMBER V ARIES WITH COLOR OF UNIT . CONT ACT YOUR LOCAL BRADLEY REP . FOR ASSIST ANCE). BOWL (P ART NUMBER V ARIES WITH COLOR OF UNIT .[...]

  • Page 14

    Express® Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation Instructions 14 8/23/07 Bradley Corporation • 215-1510 Rev . D; ECN 07-815 Assembly of Component s continued . . . Sensor assembly and solenoid valve access • T o access solenoids: Using a 5/32" Allen socket wrench, loosen, but do not remove the bott[...]

  • Page 15

    15 Express® Lavatory System - MG Series with Battery Infrared Control Installation Instructions MG-2/BIR3 Bradley Corporation • 215-1510 Rev . D; ECN 07-815 8/23/07 Assembly of Component s continued . . . Figure 1 1a INFRARED WINDOW 269-1241 SENSOR EYES 30" (251-019A) 60" (251-019B) SPRA YHEAD BODY CONNECTOR 1/4" TUBE 145-089 ACCE[...]

  • Page 16

    Express® Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation Instructions 16 8/23/07 Bradley Corporation • 215-1510 Rev . D; ECN 07-815 T roubleshooting BIR3 Component s CAUTION: T urn off water supplies to unit before troubleshooting. Problem: An individual operating station drips and fails to shut off. Cause: There[...]

  • Page 17

    17 Express® Lavatory System - MG Series with Battery Infrared Control Installation Instructions MG-2/BIR3 Bradley Corporation • 215-1510 Rev . D; ECN 07-815 8/23/07 1 2 3 4 5 6 7 8 9 8 DESCRIPTION QTY . P ART NO. REF . 11 1 118-307 V AL VE BOD Y , 1/4" CLOSED 2 1 269-983 DIAPHRA GM 3 1 192-017 ARMA TURE 4 1 135-093 SPRING 5 1 269-1729 ARMA [...]

  • Page 18

    Express® Lavatory System - MG Series with Battery Infrared Control MG-2/BIR3 Installation Instructions 18 8/23/07 Bradley Corporation • 215-1510 Rev . D; ECN 07-815 Thermost atic Mixing V alve Maintenance and T roubleshooting NOTE: Befor e attempting to tr oubleshoot the valve or disassemble the components, check for the following conditions: ?[...]

  • Page 19

    19 Express® Lavatory System - MG Series with Battery Infrared Control Installation Instructions MG-2/BIR3 Bradley Corporation • 215-1510 Rev . D; ECN 07-815 8/23/07 Strainer 173-028 T empered Line Adapter Assembly (S39-685) Option Thermostat 51 7 1 O-Ring 8 1 O-Ring Item Qty Description Repair Kit S65-259 9 6 5 4 3 2 1 7 8 Strainer (173-028) V a[...]