Bosch Appliances LTC 0495 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Bosch Appliances LTC 0495, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bosch Appliances LTC 0495 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Bosch Appliances LTC 0495. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Bosch Appliances LTC 0495 should contain:
- informations concerning technical data of Bosch Appliances LTC 0495
- name of the manufacturer and a year of construction of the Bosch Appliances LTC 0495 item
- rules of operation, control and maintenance of the Bosch Appliances LTC 0495 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bosch Appliances LTC 0495 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bosch Appliances LTC 0495, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bosch Appliances service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bosch Appliances LTC 0495.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Bosch Appliances LTC 0495 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Dinion XF – L T C 0620 & L T C 0495 series Day /Night cameras Installation Instructions 1 5-bit digital day/night camera EN Manuale d’ installation Caméra numérique jour/nu it 1 5 bits FR Installationshandbuch 1 5-Bit digitale T ag-/ Nacht- Kamera DE Installatiehandl eiding 1 5-bi ts digi tale dag /nac ht- camera NL Manual de inst alació[...]

  • Page 2

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 2 SAF ET Y P R E CAUTION S Important S afeguards 1 . Read these instructions. 2. Keep these instructions. 3. Comply with all warnings. 4. F ollow all instructions. 5. Do not use this equipment near water . 6. Clean only with d ry cloth. 7 . Do not block any v entilation[...]

  • Page 3

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 3 9. Do not defeat the safety purpose of the polarized or grounding-typ e plug. A polarized plug has two blades w ith one wider than the other . A grounding type plug has two blades and a third grounding p rong. Both the wide blade and the third prong are provided for y[...]

  • Page 4

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 4 FCC Information This equipment has been tested and found to comply w ith the limits for a Class B digital device, pursuant to part 1 5 of the FCC Rules. These limits are designed to pro vide reasonable protection against harmful interference in a residenti al installa[...]

  • Page 5

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 5 I ntrod uctio n The Dinion XF Da y/Nig ht is a high-performa nce smart surveill ance color camera. It incorporates 15-bit digi tal signal processing for outstanding picture performance under all li ghting conditions. The Dinion XF Day/Night is easy to install and r ea[...]

  • Page 6

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 6 Unpacking Unpack carefully and handle the eq uipment with care. The packaging contains : • DinionXF Da y/Night camera • CS to C lens mount adap ter • CCD protection cap • Spare lens connector (male) • These instructions Note If equipment appears to ha ve b e[...]

  • Page 7

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 7 Con necti ons Pow e r Low voltage versions High voltage versions F or low v oltage cameras: • push in the tabs to open the quick-connectors (these connections are not polarity se nsitive). • use A W G16 to 22 stranded wire or A W G 1 6 to 26 solid w ire; cut back [...]

  • Page 8

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 8 Sync Y/C V ID E O SVHS SYN C D C 1 2 V A C 24 V ALARM V ID EO SVHS SYN C ALARM V ID EO SVHS SYN C D C 1 2 V A C 2 4 V ALARM V ID E O SVHS SYN C ALARM 1 2 4 3 Pin Y/C socket 1G N D Y 2 GND C 3Y 4 C DinionXFD_Nv1_0.book Pag e 8 Friday, J anuary 7, 20 05 10:56 AM[...]

  • Page 9

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 9 Alarm connector • Max. wire diameter A W G 22- 28 for both stranded and solid • Default rela y position n.o. (norma lly open) , no alarm • Alarm output rela y sw itching capability: Max voltage 30V A C or +40VDC. Max 0. 5 A continuous , 10V A. • Alarm in: T TL[...]

  • Page 10

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 1 0 Note If a short circuit is detected on the lens connector, the on-screen displa y (OSD) failure message LENS SHOR T CIR CUIT is shown. The lens circuit is automatically disabled to av oid internal damage. Remove the le ns connector and check the pin connections. Bos[...]

  • Page 11

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 1 1 Ba ck f ocu s a dj us tme nt T o optimize picture sharpness in both bright and low-l ev el lighting, adjust the back focus. Use the camera's unique Lens Wizard (see Ad v ance d Set- up) . This ensures that the object of interest always remains in focus ev en wh[...]

  • Page 12

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 1 2 Mounting t he camera The camera can be mounted from the top or bottom. The bottom mounting is isolated from ground. Wi th outdoor scenes, a DC -iris lens is recommende d. Day/ Night switc hing The Dinion XF Da y/Nig ht Camera is equipped with a motorized IR f ilter [...]

  • Page 13

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 1 3 Advanced S et - up The Dinion XF Day/Night normally provides an optimal picture without the need for further adjustments. Ho we ver , advanced set-up options are ava ilable for getting the best results from the camera under special circumstances. There are tw o main[...]

  • Page 14

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 1 4 Menu Struc ture Mode Mode AL C Enhance Colo r BL C VMD Mode ID Defaults Exit ALC AL C level Shut/G ain Peak / averag e AL C speed Shut/Gain Shutter Defshut Sens up Gain Max. gain Day/Night ENHANCE Autoblack Blac klevel Cont our DNR XF- dyn amic Day/Night Switch leve[...]

  • Page 15

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 1 5 Installer Lens Wizard I/O Sync Came ra ID Defaults Exit Lens wizard Lens type Detected Set back focus Set level I/O Sync input Communicati on Cabl e co mp Comp lev el Alarm Alarm Alarm in Active Action Alarm out Sync Sync Detected sync V phase H phase Subphase Camer[...]

  • Page 16

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 1 6 Hints for m enu navigat ion How to use the 5 keys • Press the menu/select k ey to access the menus or to mo v e to the next or previous menu. • Press the menu/select k ey for appro ximately 1 . 5 seconds to open the Installer menu. • Use the up or down ke ys t[...]

  • Page 17

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 1 7 Mode menu AL C submenu Fun ct i on Select ion Descript ion MO DE 1 , 2, 3 Select operating mode AL C Select submenu Select to access the video level control menu E N HANC E Select submenu Select to access the picture enhancement menu COL OR Select submenu Select to [...]

  • Page 18

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 1 8 AL C --> Shutt er/Ga in submenu Note If SENS UP is active, some noise or sp ots ma y appear in the p icture. This is normal camera beha vior. SENS UP ma y cause some motion blur on moving objects. If the camera is in mono chrome mode, all color re lated menu item[...]

  • Page 19

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 1 9 Day/Night submenu Enhance submenu Fun ct i on Select ion Descript ion D A Y /NIGHT COL OR, MONO , AUTO • In COLOR mode the camera will always give a color image. • In M ON O mode the I R filter is removed , giving full I R sensitivity in a monochrome image. • [...]

  • Page 20

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 20 Color subm enu Back Light Compensation (B L C ) submenu Selecting an area T o set-up an area for BLC (or VMD), access the area menu by se lecting the AREA option from the BLC (or VMD) menu. Upon entering the AREA Fun ct i on Select ion Descript ion WH ITE BALANC E AT[...]

  • Page 21

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 2 1 menu, the current area is display ed wi th the upper left corner f lashing. The f lashing corner of the image can be mov ed with the Up, Down, Left, R ight arrow k eys. Pressing the Select k ey mo ves the f lashing cursor to the opposite corner , which can no w be m[...]

  • Page 22

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 22 Installer Set t ings Install menu Install lens wizard submenu Adjustment procedure DC-iris L ens: 1 . Unlock the back focus locking button. 2. Acce ss the L ens W izard menu. 3. SET BA CK FOCUS NOW is highlighted in the menu. 4. T urn the back focus adjustment as req[...]

  • Page 23

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 23 Adjustment procedure Manual-iris Lens: 1 . Unlock the back focus locking button . 2. Adjust the lens to the maximum lens opening. 3. T urn the back focus adjustment as required. 4. Lock th e back focus locking button. Adjustment procedure V ideo-iris Le ns: 1 . Unloc[...]

  • Page 24

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 24 Install I /O --> Alarm submenu Install sync submenu Note VPHASE , HPHASE and SUB-PHASE cannot be accessed if there is no valid locking sign al. Fun ct i on Select ion Descript ion ACTIVE NON E , H IG H, LOW Selects active_HI G H or active_L OW for the alarm input [...]

  • Page 25

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 25 Install I D submenu Defaults submenu Camera Control Communication This camera is equipped with a coaxial communic ations transceiv er . In combination with VP-CFGSF T , the camera can be adjusted from the head- end side of the coaxial c able. All menus can be ac cess[...]

  • Page 26

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 26 T echnical specific at ion 1 /2" CCD versions T ype number LT C 0620/ 1 1 LT C 0620/2 1 LT C 0620/5 1 LT C 0620/61 Standard P AL NTSC P AL NTSC Active pixels 752x582 768 x 49 2 75 2 x5 8 2 768x492 Rated supply voltage 24 VA C or 1 2 VDC 1 2- 28 V AC (50/60 Hz) 1[...]

  • Page 27

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 27 Day/Night Color, Mono, Auto Sens Up Adjustable from OF F to 1 0x Auto black On , Off selectable (max imum level selectable up to 28dB ) AGC AGC on o r off (0 dB) select able XF- D YN Automatic dynamic range enhancement level selectable DNR Automatic noise filtering O[...]

  • Page 28

    Dinion XF | Installation Manual Bosch Security Syst ems | 2004-0 1 | V1 .0 EN | 28 Accessories Power transformers • TC1 334 120V AC, 60 Hz - 24V A C, 30V A • TC120PS 120V AC, 60 Hz - 1 5VDC, 9V A • TC220PSX -24 220- 240V AC, 50/6 0Hz - 24V A C, 30V A • TC220PS 220- 240V A C, 50/60Hz - 15VDC, 9 V A Inte rface box : • VP-CFGSFT Bilinx™ co[...]

  • Page 29

    Bosch Sicherheitssysteme GmbH Ludwig-Bölkow-Allee 8552 1 Ottobrunn Germany www .bosch-sicherheitssysteme.de © 2004 Bosch Security Systems B.V . Subject to change. Printed in Portugal. 3 1 22 1 65 2306 1 Bosch Security Systems B.V . P .O. Box 80002 5600 JB Eindhove n The Netherlands www.bosc hsecuritysystems .com DinionXFD_Nv1_0.book Pag e 1 Frida[...]