Bosch Appliances FPA-1000 manual

1
2
3
4
5
6
7
8

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Bosch Appliances FPA-1000, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bosch Appliances FPA-1000 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Bosch Appliances FPA-1000. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Bosch Appliances FPA-1000 should contain:
- informations concerning technical data of Bosch Appliances FPA-1000
- name of the manufacturer and a year of construction of the Bosch Appliances FPA-1000 item
- rules of operation, control and maintenance of the Bosch Appliances FPA-1000 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bosch Appliances FPA-1000 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bosch Appliances FPA-1000, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bosch Appliances service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bosch Appliances FPA-1000.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Bosch Appliances FPA-1000 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Fire Alarm Systems | FPA‑1000 Analog Addressable Fire Panels FPA‑1000 Analog Addressable Fire Panels www.boschsecurity.com u Support for up to 508 points on two analog addressable loops u Built-in Ethernet connector for web-browser based programming and Conettix Alarm-over-IP communication u Two on-board NACs and dual-line PSTN DACT u Peer-to-p[...]

  • Page 2

    interface. Therefore, no software installation is required. The panel can receive diagnostics from a Web browser running on a networked PC. System Overview Functions Peer-to-peer Communications The FPA‑1000 panels (-V2) allow peer-to-peer networking of up to eight panels in a single group supporting a system which can include up to 2000 points. N[...]

  • Page 3

    On-board Relays Three programmable on-board relays default to global alarm (zone 226), global system trouble (zone 227), and global system supervisory (zone 228). They can be programmed to activate on a variety of conditions including gas alarm. Option Bus On the Option Bus, the FPA-1000 supports: • up to eight FMR-1000-RCMD Remote Command Center[...]

  • Page 4

    use these devices on addresses above 127 and other devices below address 127. All compatible detectors and modules are addressed using the D5070 Programmer. Parts Included Quant. Component 1 FPA‑1000‑V2 main board 1 Enclosure with transformer 1 Enclosure lock and two keys 1 (replacement key: D102) 1 Hardware pack 3 Wiring labels (one each in En[...]

  • Page 5

    • Connections: Pluggable terminal blocks for AUX, Option Bus, SLC, NAC, Main Board Relays • Wire Gauge: 12 AWG to 18 AWG (0.75 mm 2 to 3.25 mm 2 ) Enclosure • Material: Cold rolled steel, 19 gauge (1.2 mm) • Color: Red Dimensions • Enclosure (W x H x D): 14.5 in. x 4.3 in. x 22.7 in. (36.8 cm x 10.9 cm x 57.7 cm) • with trim ring (W x D[...]

  • Page 6

    FAA‑325‑B6 6‑inch Analog Sensor Base 6‑inch (152.4 mm) base for FAH‑325, FAI‑325, and FAP‑325 sensors. US sales only! Order number FAA-325-B6 FAA‑325‑B6S Analog Sounder Base Contains an addressable sounder which provides an audible alarm in the immediate vicinity and only works in combination with one of the FAH‑325, FAI-325, or[...]

  • Page 7

    FLM‑325‑2R4‑2A Dual Relay Module 2 A Provides 2 A current at two independently-controlled Form C contacts for a variety of Normally Open and Normally Closed applications; compatible with 254 addresses Order number FLM-325-2R4-2A FLM‑325‑2R4‑2AI Dual Relay Module 2 A with Isolator Provides 2 A current with built-in short circuit isolator[...]

  • Page 8

    FPP‑RNAC‑8A‑4C Remote Notification Appliance Circuit (RNAC) Power Supply Adds four additional notification appliance circuits to a fire alarm control panel Order number FPP-RNAC-8A-4C 8 | FPA‑1000 Analog Addressable Fire Panels Represented by: Americas: Europe, Middle East, Africa: Asia-Pacific: China: America Latina: Bosch Security Systems[...]