A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Blue Rhino 200209-450000, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Blue Rhino 200209-450000 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Blue Rhino 200209-450000. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Blue Rhino 200209-450000 should contain:
- informations concerning technical data of Blue Rhino 200209-450000
- name of the manufacturer and a year of construction of the Blue Rhino 200209-450000 item
- rules of operation, control and maintenance of the Blue Rhino 200209-450000 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Blue Rhino 200209-450000 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Blue Rhino 200209-450000, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Blue Rhino service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Blue Rhino 200209-450000.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Blue Rhino 200209-450000 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Replacing Contr ol V alve ® Series: 200209 – 450000 LP Gas[...]

  • Page 2

    Replacing Control V alv es Series 200209 – 450000 LP Gas 404121 1 ® For assistance call 1.800.762.1142. Replacing Control V alves Series 200209 – 450000 LP Gas 404121 2 ® For assistance call 1.800.762.1142. T ools required: • # 2 Phillips scre w dr iv er • 8mm open end wrench • 9mm open end wrench • 10mm open end wrench • 12mm open [...]

  • Page 3

    Replacing Control V alv es Series 200209 – 450000 LP Gas 404121 1 ® For assistance call 1.800.762.1142. Replacing Control V alv es Series 200209 – 450000 LP Gas 404121 2 ® For assistance call 1.800.762.1142. Steps 1-5 1. T ur n y our LP gas tank off , unscrew regulator and remo ve LP gas tank. 2. Remov e the dome . 3. Remov e the access panel[...]

  • Page 4

    Replacing Control V alv es Series 200209 – 450000 LP Gas 404121 3 ® For assistance call 1.800.762.1142. Replacing Control V alves Series 200209 – 450000 LP Gas 404121 4 ® For assistance call 1.800.762.1142. Step 6 Remov e emitter screen: A. 200209, 200308, 200605 – remov e the 4 scre ws using a Phillips screw driver that attach the emitter [...]

  • Page 5

    Replacing Control V alv es Series 200209 – 450000 LP Gas 404121 3 ® For assistance call 1.800.762.1142. Replacing Control V alv es Series 200209 – 450000 LP Gas 404121 4 ® For assistance call 1.800.762.1142. Step 7 1. Disconnect the b ur ner supply tube from the control valv e , using a 5/8” open end wrench. Note: There is a brass nut on th[...]

  • Page 6

    Replacing Control V alv es Series 200209 – 450000 LP Gas 404121 5 ® For assistance call 1.800.762.1142. Replacing Control V alves Series 200209 – 450000 LP Gas 404121 6 ® For assistance call 1.800.762.1142. Step 8 1. Disconnect the pilot supply tube using the #10mm open end wrench. Note: Y ou ma y need to use the #12mm open end wrench to hold[...]

  • Page 7

    Replacing Control V alv es Series 200209 – 450000 LP Gas 404121 5 ® For assistance call 1.800.762.1142. Replacing Control V alv es Series 200209 – 450000 LP Gas 404121 6 ® For assistance call 1.800.762.1142. Step 9 Disconnect the ther mal-couple 1. Remov e the scre w from the access panel on the rear of the valv e housing. 2. Remov e the acce[...]

  • Page 8

    Replacing Control V alv es Series 200209 – 450000 LP Gas 404121 7 ® For assistance call 1.800.762.1142. Replacing Control V alves Series 200209 – 450000 LP Gas 404121 8 ® For assistance call 1.800.762.1142. Step 10 Disconnect the control v alv e 1. Remov e the brass n ut that holds the control v alve in the v alv e housing using the 3/4” op[...]

  • Page 9

    Replacing Control V alv es Series 200209 – 450000 LP Gas 404121 7 ® For assistance call 1.800.762.1142. Replacing Control V alv es Series 200209 – 450000 LP Gas 404121 8 ® For assistance call 1.800.762.1142. Step 11 Re-install pilot supply tube and the control v alv e: 1. Connect the pilot supply tube to the control v alve 2. Place the contro[...]

  • Page 10

    Replacing Control V alv es Series 200209 – 450000 LP Gas 404121 9 ® For assistance call 1.800.762.1142. Replacing Control V alves Series 200209 – 450000 LP Gas 404121 10 ® For assistance call 1.800.762.1142. Step 12 Reinstall the ther mal-couple: 1. Attach the ther mal-couple to the bac k of the control valv e in the v alv e housing. Finger t[...]

  • Page 11

    Replacing Control V alv es Series 200209 – 450000 LP Gas 404121 9 ® For assistance call 1.800.762.1142. Replacing Control V alv es Series 200209 – 450000 LP Gas 404121 10 ® For assistance call 1.800.762.1142. Step 13 1. Slide the burner assembly into the v alv e housing. 2. Attach the burner supply tube to the top of the control valv e . Do n[...]

  • Page 12

    Replacing Control V alv es Series 200209 – 450000 LP Gas 404121 11 ® For assistance call 1.800.762.1142. Replacing Control V alves Series 200209 – 450000 LP Gas 404121 12 ® For assistance call 1.800.762.1142. Step 14 1. Attach the pilot to the pilot brac ket. 2. Connect the pilot supply tube to the pilot.[...]

  • Page 13

    Replacing Control V alv es Series 200209 – 450000 LP Gas 404121 11 ® For assistance call 1.800.762.1142. Replacing Control V alv es Series 200209 – 450000 LP Gas 404121 12 ® For assistance call 1.800.762.1142. Step 15 200209, 200308, 200605 1. Attach the emitter to the v alve housing, using 3 scre ws . 2. Secure. 230000 - 450000 1. Place the [...]

  • Page 14

    Replacing Control V alv es Series 200209 – 450000 LP Gas 404121 13 ® For assistance call 1.800.762.1142. Replacing Control V alves Series 200209 – 450000 LP Gas 404121 14 ® For assistance call 1.800.762.1142. Steps 16-19 16. Attach the engine to the post 17. Bur ner Connections 1. Mak e sure the regulator valv e and hose connections are secur[...]

  • Page 15

    Replacing Control V alv es Series 200209 – 450000 LP Gas 404121 13 ® For assistance call 1.800.762.1142. Replacing Control V alv es Series 200209 – 450000 LP Gas 404121 14 ® For assistance call 1.800.762.1142. Step 20 - IMPOR T ANT P erform leak c heck. W ARNING FOR Y OUR SAFETY If y ou smell gas - 1. Shut off gas to appliance . 2. Extinguish[...]

  • Page 16

    Replacing Control V alv es Series 200209 – 450000 LP Gas 404121 15 ® For assistance call 1.800.762.1142. T ank/Gas Line Connection 1. Make 2-3 oz. of leak solution by mixing one par t liquid dishwashing soap with three par ts water . 2. Make sure control knobs are off . 3. T ur n LP gas tank ON at valv e. 4. Spoon leak check solution at all “x[...]

  • Page 17

    Blue Rhino Global Sourcing, LLC 104 Cambridge Plaza Dr iv e, Winston-Salem, NC 27104 USA 1.800.762.1142, www .bluerhino .com © 2004 Blue Rhino Global Sourcing, LLC All Rights Reser ved. Endless Summer ® is a registered trademark of Blue Rhino Global Sourcing, LLC All Rights Reser ved. Blue Rhino ® is a registered trademark of Ferrellgas , L.P . [...]