Black Box IC477A-F-R2 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Black Box IC477A-F-R2, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Black Box IC477A-F-R2 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Black Box IC477A-F-R2. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Black Box IC477A-F-R2 should contain:
- informations concerning technical data of Black Box IC477A-F-R2
- name of the manufacturer and a year of construction of the Black Box IC477A-F-R2 item
- rules of operation, control and maintenance of the Black Box IC477A-F-R2 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Black Box IC477A-F-R2 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Black Box IC477A-F-R2, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Black Box service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Black Box IC477A-F-R2.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Black Box IC477A-F-R2 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mail order: Black Box Corporation , 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com • E-mail: info@blackbox.com FEBRUARY [...]

  • Page 2

    1 ASYNC 2 3 2 ↔ 422/485 CONVERTER FEDERAL COMMUNICATIONS COMMISSION AND CANADIAN DEPARTMENT OF COMMUNICATIONS RADIO FREQUENCY INTERFERENCE STATEMENTS This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications. L[...]

  • Page 3

    2 ASYNC 232 ↔ 422/485 CONVERTER NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY STATEMENT INSTRUCCIONES DE SEGURIDAD .[...]

  • Page 4

    3 ASYNC 2 3 2 ↔ 422/485 CONVERTER[...]

  • Page 5

    4 ASYNC 232 ↔ 422/485 CONVERTER Contents[...]

  • Page 6

    5 Data Rate Connectors Transmission Format Transmission Line Transmission Mode Range Control Signals Carrier Surge Protection RTS/CTS Delay MTBF Operating Temperature CHAPTER 1: Specifications 1. Specifications[...]

  • Page 7

    6 ASYNC 232 ↔ 422/485 CONVERTER Humidity Altitude Power Size Shipping Weight[...]

  • Page 8

    7 CHAPTER 2: Introduction ↔ Section 4.4 2. Introduction[...]

  • Page 9

    8 ASYNC 232 ↔ 422/485 CONVERTER ↔ DCE DTE +RCV -G-XMT+ 3. Configuration DTE/DCE Switch Terminal Block[...]

  • Page 10

    9 3.1 Setting the DTE/DCE Switch ON 1 2 3 4 5 6 7 8 CHAPTER 3: Configuration DIP Switch S1[...]

  • Page 11

    10 ASYNC 232 ↔ 422/485 CONVERTER 3.2 DIP-Switch Configuration internally ON OFF ON 1 2 3 4 5 6 7 8[...]

  • Page 12

    11 CHAPTER 3: Configuration 3.2.1 DIP-S WITCH S ETTINGS Switch S1 Summary Table Position Function Factory Default S1-1* “Transmit Off” Impedance Off High Z S1-2* “Transmit Off” Impedance Off S1-3 RTS/CTS Delay On 8 msec. S1-4 Echo Mode Off Echo Off S1-5 Carrier Control On Controlled by RTS S1-6 Receive Impedance On 120 ohm S1-7* 2 wire/4 wi[...]

  • Page 13

    12 ASYNC 232 ↔ 422/485 CONVERTER S1-4: Echo Mode S1-5: Carrier-Control Method NOTE Carrier is ON when RTS is asserted positive, and OFF only when RTS is driven to a negative voltage. S1-6: Receive Impedance (Termination) S1-7 and S1-8: 2-wire/4-wire Modes[...]

  • Page 14

    13 CHAPTER 3: Configuration 3.2.2 C ONFIGURATION S WITCH A PPLICATIONS Do not change switch settings until you have carefully read this manual. Typical Switch Applications Switch Settings Point-to-Point Multipoint 4W 4W HDX 2W 4W 2W “Xmt Off” Imp. (S1-1) Off Off Off Off Off “Xmt Off” Imp. (S1-2) Off Off Off Off Off RTS/CTS Delay (S1-3) On O[...]

  • Page 15

    14 ASYNC 232 ↔ 422/485 CONVERTER 4.1 Connection to the RS-485 Interface must 4.1.1 4-W IRE C ONNECTION U SING THE DB25 (IC477A-X-R2 AND IC478A-X-R2) Converter RS-485 (530) Device Signal DB25 Pin DB25 Pin Signal XMTA 2......................................3 RCVA XMTB 14....................................16 RCVB RCVA 3.............................[...]

  • Page 16

    15 CHAPTER 4: Installation 2) It is not necessary that the RS-485 device adhere to the RS-530 standard. However, you must make sure that the signals, polarities, and pairing of your connection conform to this table. 3) If you are not using two IC477A-X-R2s or IC478A-X-R2s back to back and the procedure on the previous page produces garbage data (or[...]

  • Page 17

    16 ASYNC 232 ↔ 422/485 CONVERTER 5. the other pair of wires NOTE Positive and negative are relative terms and may not always have the same relationship for all RS-422 or RS-485 devices (see the previous note regarding “flipping the leads”). Converter RS-485 Device XMT+ ............................................................RCVA XMT- ....[...]

  • Page 18

    17 8. 9. +RCV -G-XMT+ +RCV -G-XMT+ +RCV -G-XMT+ CHAPTER 4: Installation[...]

  • Page 19

    18 ASYNC 232 ↔ 422/485 CONVERTER 10. 11. 4.1.3 2-W IRE C ONNECTION only the transmit (XMT) pair Converter Signal RS-485 Signal XMT+ ..................................+ (positive) XMT-...................................- (negative) IMPORTANT! If you are not using two IC476A-X-R2s back to back and the procedure on the previous page produces garbage[...]

  • Page 20

    19 CHAPTER 4: Installation 4.2 Connection to the RS-232 Interface NOTE If you must use a cable to connect the Converter to the RS-232 device, make sure it is a straight-through cable of the shortest possible length. We recommend no more than 6 ft. (1.8 m). 4.3 Wiring for Multipoint Applications NOTE Connections are to screw terminals directly on th[...]

  • Page 21

    20 ASYNC 232 ↔ 422/485 CONVERTER 4.4 Operation data[...]

  • Page 22

    21 APPENDIX A: RS-232C Pin Configurations ST ANDARD “DTE” SETTING DIRECTION DIRECTION From Converter Data T erm. Ready (DTR) - 20 1- (FG) Frame Ground 2- (TD) T ransmit Data 3- RD) Receive Data 4- (RTS) Request to Send 5- (CTS) Clear to Send 6- (DSR) Data Set Ready 7- (SG) Signal Ground 8- (DCD) Data Carrier Detect From Converter T o Converter [...]

  • Page 23

    22 ASYNC 232 ↔ 422/485 CONVERTER Pin Number Pin Name Appendix B . 422/485 (530) Pin Configuration[...]

  • Page 24

    23 APPENDIX C: Self-Test Section 3.2.2 Appendix C. Self- T est[...]

  • Page 25

    1000 Park Drive • Lawrence, PA 15055-1018 • 724-746-5500 • Fax 724-746-0746 © Copyright 1998. Black Box Corporation. All rights reserved.[...]