Beckett CF 2500/ 3500 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Beckett CF 2500/ 3500, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Beckett CF 2500/ 3500 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Beckett CF 2500/ 3500. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Beckett CF 2500/ 3500 should contain:
- informations concerning technical data of Beckett CF 2500/ 3500
- name of the manufacturer and a year of construction of the Beckett CF 2500/ 3500 item
- rules of operation, control and maintenance of the Beckett CF 2500/ 3500 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Beckett CF 2500/ 3500 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Beckett CF 2500/ 3500, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Beckett service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Beckett CF 2500/ 3500.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Beckett CF 2500/ 3500 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    2500/3500 MODEL MODEL MODEL MODEL MODEL CF CF 2500/ 3500 Instruction M anual Oil Burner Thank you for purchasing a Beckett burner . With proper care and regular maintenance, it will provide years of trouble-free service. Please take a few minutes to read the section entitled “T o the owner” inside this manual. Then, keep the manual in a safe pl[...]

  • Page 2

    Instruction Manual – Model CF2500/CF3500 Oil Burner 2 Form 6104 BCF-35-R0699 Please . . . r ead this page first Denotes presence of a hazard which, if ignored, could result in minor personal injury or property damage. Hazard definitions The following will be used throughout this manual to bring attention to hazards and their risk factors, or to s[...]

  • Page 3

    Instruction Manual – Model CF2500/CF3500 Oil Burner 3 Form 6104 BCF-35-R0699 W arranty Beckett warrants its equipment to those who have purchased it for resale, including your dealer . If you have an y problems with your equipment or its installation, you should contact your dealer for assistance. Specifications Fuels #1 or #2 Fuel Oil Firing ran[...]

  • Page 4

    Instruction Manual – Model CF2500/CF3500 Oil Burner 4 Form 6104 BCF-35-R0699 Pr e-installation checklist T able 1 – Nozzle capacities at various pressures ❏ Combustion air supply • The burner requires combustion air and ventilation air for reliable operation. Assure that the building and/or com- bustion air openings comply with National Fir[...]

  • Page 5

    Instruction Manual – Model CF2500/CF3500 Oil Burner 5 Form 6104 BCF-35-R0699 3502 E D G F T 2 ° 1 T able 2 – Air tube capacity vs. firebox pressure Figure 2 – Air tube mounting dimensions E Insertion depth G Air tube to inside of chamber – 0.25" ± 0.125" T Air tube length D Tube diameter Figure 1 – Min. combustion chamber dime[...]

  • Page 6

    Instruction Manual – Model CF2500/CF3500 Oil Burner 6 Form 6104 BCF-35-R0699 Mount the bur ner ❏ Mount flange(s) on air tube • This section does not apply to burners with welded flanges. • Do not install air tube on burner . • For non-pressure firing flange , refer to Figure 3 : Install gasket (item a ) and flange (item d ). Ignore the ne[...]

  • Page 7

    Instruction Manual – Model CF2500/CF3500 Oil Burner 7 Form 6104 BCF-35-R0699 Z 3506 a Measure dimension from front (flat) face of head to end of air tube, as sho wn. Z b d c Figure 5 – Nozzle line assembly in burner ❏ ❏ ❏ ❏ ❏ Set dimension Z • Replace the rear access door on the burner , making sure that the adjusting plate assembly[...]

  • Page 8

    Instruction Manual – Model CF2500/CF3500 Oil Burner 8 Form 6104 BCF-35-R0699 Connect fuel line(s) ❏ Fuel unit by-pass plug The CF2500A, CF2500 and CF3500A burners are shipped without the by-pass plug installed. Y ou must install this plug on tw o- pipe systems. DO NOT install the by-pass plug in the fuel unit if connected to a one-pipe oil syst[...]

  • Page 9

    Instruction Manual – Model CF2500/CF3500 Oil Burner 9 Form 6104 BCF-35-R0699 Figure 9a T wo-pipe oil flow , one nozzle, low fire, “ H ” pump • Install two high-quality shutoff valves in accessible loca- tions on the oil supply line. Locate one valve close to the tank. Locate the other v alve close to the burner , upstream of the fuel filter[...]

  • Page 10

    Instruction Manual – Model CF2500/CF3500 Oil Burner 10 Form 6104 BCF-35-R0699 Wir e the bur ner Install the burner and all wiring in accordance with the National Electrical Code and all applicable local codes or requirements. W ire the burner in compliance with all instructions pro vided by the appliance manufacturer . V erify operation of all co[...]

  • Page 11

    Instruction Manual – Model CF2500/CF3500 Oil Burner 11 Form 6104 BCF-35-R0699 Sequence of operation — typical 1. On call for heat from the appliance operating controls (and the circuit from T to T of the R8184 closed), power is applied to the R8184 black wire ( BK ). 2. The R8184 applies 120 volts to the orange wire ( OR ), acti- vating the bur[...]

  • Page 12

    Instruction Manual – Model CF2500/CF3500 Oil Burner 12 Form 6104 BCF-35-R0699 Pr epar e the bur ner for star t-up - continued ❏ Z dimension • Should be set per these instructions (see page 7). The top acorn nut ( Figure 11 , item d ) should never be loosened once the Z dimension is initially set. ❏ Adjusting plate assembly (Figure 11) • M[...]

  • Page 13

    Instruction Manual – Model CF2500/CF3500 Oil Burner 13 Form 6104 BCF-35-R0699 T able 5 – Initial air adjusting plate settings (damper position) Figure 12 – Air damper and damper motor assembly Legend (Figure 12) a Damper motor – do not adjust internal cam b Arm assembly c Ball joint assembly – do not adjust position of ball joint d Damper[...]

  • Page 14

    Instruction Manual – Model CF2500/CF3500 Oil Burner 14 Form 6104 BCF-35-R0699 Star t the bur ner Do not proceed unless all prior steps in this manual have been completed. Failure to comply could result in sev ere personal injury , death or substantial property damage. Do not attempt to start the burner when excess oil has accumulated, when the ap[...]

  • Page 15

    Instruction Manual – Model CF2500/CF3500 Oil Burner 15 Form 6104 BCF-35-R0699 Maintenance and ser vice Annual service — by qualified service technician Have the burner inspected, tested and started at least annually by a qualified service technician. This annual test/inspection should include at least the following: ❏ Replace oil nozzles. ❏[...]

  • Page 16

    Instruction Manual – Model CF2500/CF3500 Oil Burner Form 6104 BCF-35-R0699 U.S.A.: P . O. Box 1289 • Elyria, Ohio 44036 • 800-645-2876 • 440-327-1060 • F AX 440-327-1064 Canada: R. W . Beckett Canada, Ltd. • 430 Lair d Road • Guelph, Ontario, N1G 3X7 • 800-665-6972 • F AX 519-763-5656 Item Part name Description Part number 1 Air t[...]