BEA LO-21P manual

1
2
3
4
5
6
7
8
9
10
11
12
13

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of BEA LO-21P, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of BEA LO-21P one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of BEA LO-21P. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of BEA LO-21P should contain:
- informations concerning technical data of BEA LO-21P
- name of the manufacturer and a year of construction of the BEA LO-21P item
- rules of operation, control and maintenance of the BEA LO-21P item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of BEA LO-21P alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of BEA LO-21P, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the BEA service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of BEA LO-21P.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the BEA LO-21P item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    75.5079.08 20061129 Page 1 of 13 PRODUCT DESCRIPTION TECHNICAL SPECIFICATIONS USERS GUIDE LO-21P LOCK OUT RELAY COMPONENT ID SA FET Y PRECAUTIONS The microprocessed LO-21P (PN: 10L O21P) Lock Out Relay is designed to provide a lockout function for the BEA Bodyguard presence sensor, when used with the c omplete Parallax System. The L O-21P uses the [...]

  • Page 2

    75.5079.08 20061129 Page 2 of 13 ELECTRICAL INSTALLATION – OPTION 1 – STANDARD WIRING STANDARD WIRING WIRE CONNECTIONS Black Motor Input - Red Motor Input + Purple Bodyguard COM. Pin 3 White Bodyguard Data (-) Pin 6 Black / White Activation Sensor COM. Orange Power input / 12-24 VAC/VDC ( - ) Gray Bodyguard N.O. Pin 4 Red / White Bodyguard Data[...]

  • Page 3

    75.5079.08 20061129 Page 3 of 13 ELECTRICAL INSTALLATION OPTION 2 – Operator Mounte d Switch Wiring diagram below shows how to wire when using an operator-mounted switch to control the flow of voltage from the motor to the lockout module. Switch should be set to close a se t of dry contacts when door is within 2 to 3 degrees of the full open posi[...]

  • Page 4

    75.5079.08 20061129 Page 4 of 13 ELECTRICAL INSTALLATION Option 3 – Double Pole Double Throw Switch The wiring diagram below shows how to wire a DPDT switch to control the On-Off-Hold function, as well as dat a between the motor and the LO21 P. brown red/white white gray purple orange LO-21P 24 V TRANSFORMER DATA + 7 DATA - 6 N.C. 5 N.O. 4 COM 3 [...]

  • Page 5

    75.5079.08 20061129 Page 5 of 13 SET-UP INSTRUCTIONS Upon completion of all wiring, proceed with the set-up as follows: 1. Insure that the On-Off-Hold Open switch is in the ON position, and insure that the door control is powered and operating normally. 2. Power the Bodyguar d sensor and, using a BEA Remote Co ntrol, unlock the sens or and change t[...]

  • Page 6

    75.5079.08 20061129 Page 6 of 13 SETUP INSTRUCTION Cont. DIPSWITCH 6, 7 and 8 OPERATION 7. Adjustment is necessary to configure the dipswitche s to obtain the correct lock out time dela y . To set the dipswitches( 1 through 5) for lock out time, perform the following:  Activate the door to the open position.  Time the overall door closing cyc[...]

  • Page 7

    75.5079.08 20061129 Page 7 of 13 COMPANY CONTACT TROUBLE- SHOOTING PROBLEM PROBABLE CAUSE CORRECTIVE ACTION Door will not open – all LED’s are OFF at the LO21P 1. Faulty door control 2. Faulty LO21P 3. Faulty On-Off-Hold Open switch 4. Faulty Eagle 5. Faulty wiring 1. Insure input power is good at LO21P – orange and brown wires. Should be 12 [...]

  • Page 8

    75.5079.08 20061129 Page 8 of 13 BODYGUARD DK-12 DATA + 7 DATA - 6 N.C. 5 N.O. 4 COM 3 POWER 2 POWER 1 5 N/C 4 N/O 3 COM 2 PWR 1 PWR 24 V TRANSFORMER 1 1 5 V A C SIZE: SHEET: SCALE: A PH: (412) 249-4100 FAX: (412) 249-4101 B.E.A., Inc. 100 Enterprise Drive Pittsburgh, PA 15275 DATE: www.beasensors.c om CAGE CODE: DWG NO: FILE OF: DRAWN BY: REV: 1 O[...]

  • Page 9

    75.5079.08 20061129 Page 9 of 13 BODYGUARD DK-12 DATA + 7 DATA - 6 N.C. 5 N.O. 4 COM 3 POWER 2 POWER 1 5 N/C 4 N/O 3 COM 2 PWR 1 PWR 24 V TRANSFORMER 1 1 5 V A C HOLD OPEN OFF SIZE: SHEET: SCALE: A PH: (412) 249-4100 FAX: (412) 249-4101 B.E.A., Inc. 100 Enterprise Drive Pittsburgh, PA 15275 DATE: www.beasensors.com CAGE CODE: DWG NO: FILE OF: DRAWN[...]

  • Page 10

    75.5079.08 20061129 Page 10 of 13 BODYGUARD DK-12 DATA + 7 DATA - 6 N.C. 5 N.O. 4 COM 3 POWER 2 POWER 1 5 N/C 4 N/O 3 COM 2 PWR 1 PWR 24 V TRANSFORMER 1 1 5 V A C SIZE: SHEET: SCALE: A PH: (412) 249-4100 FAX: ( 412) 249-4101 B.E.A., Inc. 100 Enterprise Driv e Pittsburgh, PA 15275 DATE: www.beasensors.com CAGE CODE: DWG NO: FILE OF: DRAWN BY: REV: 1[...]

  • Page 11

    75.5079.08 20061129 Page 11 of 13 BODYGUARD DK-12 DATA + 7 DATA - 6 N.C. 5 N.O. 4 COM 3 POWER 2 POWER 1 5 N/C 4 N/O 3 COM 2 PWR 1 PWR 24 V TRANSFORMER 1 1 5 V A C SIZE: SHEET: SCALE: A PH: (412) 249-4100 FAX: (412) 249-4101 B.E.A., Inc. 100 Enterprise Drive Pittsburgh, PA 15275 DATE: www.beasensors.com CAGE CODE: DWG NO: FILE OF: DRAWN BY: REV: 1 O[...]

  • Page 12

    75.5079.08 20061129 Page 12 of 13 B O D Y G U A R D D K - 1 2 DATA + 7 DATA - 6 N.C. 5 N.O. 4 COM 3 POWER 2 POWER 1 5 N/C 4 N/O 3 COM 2 PWR 1 PWR SIZE: S H E E T : S C A L E : A P H : ( 4 1 2 ) 2 4 9 - 4 1 0 0 F A X : ( 4 1 2 ) 2 4 9 - 4 1 0 1 B . E . A . , I n c . 1 0 0 E n t e r p r i s e D r i v e P i t t s b u r g h , P A 1 5 2 7 5 D A T E : w [...]

  • Page 13

    75.5079.08 20061129 Page 13 of 13 BODYGUARD DK-12 DATA + 7 DATA - 6 N.C. 5 N.O. 4 COM 3 POWER 2 POWER 1 5 N/C 4 N/O 3 COM 2 PWR 1 PWR SIZE: SHEET: SCALE: A PH: (412) 249-4100 FAX: (412) 249-4101 B.E.A., Inc. 100 Enterprise Drive Pittsburgh, PA 15275 DATE: www.beasensors.com CAGE CODE: DWG NO: FILE OF: DRAWN BY: REV: 1 OF 1 NTS TITLE: BESAM CUP VER.[...]