Barnet Ensign Ross ED810 manual

1
2
3
4
5
6
7
8
9
10

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Barnet Ensign Ross ED810, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Barnet Ensign Ross ED810 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Barnet Ensign Ross ED810. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Barnet Ensign Ross ED810 should contain:
- informations concerning technical data of Barnet Ensign Ross ED810
- name of the manufacturer and a year of construction of the Barnet Ensign Ross ED810 item
- rules of operation, control and maintenance of the Barnet Ensign Ross ED810 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Barnet Ensign Ross ED810 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Barnet Ensign Ross ED810, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Barnet Ensign Ross service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Barnet Ensign Ross ED810.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Barnet Ensign Ross ED810 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    INSTRUCTION MAN UAL ED810 GAS DE TECTOR I N D E X P a g e N o . IMPOR TANT NOTE 2 ATEX REQUIR EMENTS 2 MARKING 3 GENERAL 3 INSTALLATI ON 4 SOLENOI D VALVE 5 SENSORS 6 OPERATI NG INSTRUCTIONS 7 CALIBR ATION - SEMICONDUC TOR 7 CALIBR ATION – HEAD ELECTRONI CS 8 DECLARA TION OF CONFORMI TY 10 ED810 EC- TYPE EXAMINATIO N CERTIFICATE 11 ZB EC- TYPE EX[...]

  • Page 2

    ED810 INSTRUCTION MANUAL 27-02-07 2 IMPORTANT 1. The equipment suppl ied must not be m odi fied in any way since modifications will invalidate intrinsic saf ety certification, MCA and Lloyds app roval. 2. Care should be taken du r ing s ervicing as h igh voltages may be present on the ou tput contacts. 3. It is important to note th at the ED810 con[...]

  • Page 3

    ED810 INSTRUCTION MANUAL 27-02-07 3 MARKING All units have a rating label which carries the f ollowing important info rmation:- Model type: GAS DETECTOR TYPE E D810 Input voltage: 12Vdc/24Vdc (delete as appropriate) Vmax in; Um: 250V Code: [EEx ia] II C Certificate no. Baseefa03ATEX0507 Epsilon x, gas group II (1) G and category: CE mark ing, Notif[...]

  • Page 4

    ED810 INSTRUCTION MANUAL 27-02-07 4 INSTALLAT ION Note only EDL m anufac tured sensor s, which are suita bly certified can be c onnected to the ED810 and fitted in the Hazardous Area. The ED810 control unit and all uncert ified equipment should be located in the Safe Area o nly. Control Unit: The uni t should be mounted in a conv enient posi tion f[...]

  • Page 5

    ED810 INSTRUCTION MANUAL 27-02-07 5 In addition to the zene r barrier fuses (which can not be replaced) each se nsor is indiv i dually fused on the base board PCB. I f a sensor fails to respond the nom i nal 5V b etween blue and brown terminals should be checked and th e 160mA quick blow (F ) changed if necessa ry. Sensor Wiring: The Sensor cable s[...]

  • Page 6

    ED810 INSTRUCTION MANUAL 27-02-07 6 SENSORS Type EDF 1B, 2B, 3B a nd 3Bfig are sem i conducto r elem ents housed in a certified flam epr oof stainless steel housing . The housing has a male M32 t hread which can be screwe d into a conduit or suitable junction box. The sem iconductor sensors are av ailable in the f ollowing types:- a) EDF1B flam epr[...]

  • Page 7

    ED810 INSTRUCTION MANUAL 27-02-07 7 OPERATING INST RUCTIONS When power is first app lied the power light should illum i nate imm edia tely. The A1 and A2 lights of semiconduc tor sensors will illum i nate with in a few seconds and w ill be ready to be reset after a few m inutes, provided the sen sors are in cl ean air. The alarm l ights and re lays[...]

  • Page 8

    ED810 INSTRUCTION MANUAL 27-02-07 8 EDS/C and EDS/P Tran smitters INITIAL S ETUP It is vitally im portant that the ED810 an d EDS/C or P transmitter are calibrat ed tog ether ensuring that the ED810 indicates an alarm at the cor rect concentration. After installation is complete the following se tu p procedure should be fol lowed m atching the EDS/[...]

  • Page 9

    ED810 INSTRUCTION MANUAL 27-02-07 9 EDS/P 1. At EDS/P transmitter measure between – I /P and + I/P, ensure voltage reading is i n the range 4.0 – 5.4V with a Dig ital volt meter. 2. Using the Zero adjustment potentiom eter on the EDS/P, rotate cl ockwise until the 50% lamp is just illum inated or 0.3V is m easured on the O/P terminal w.r.t 0V. [...]

  • Page 10

    ED810 INSTRUCTION MANUAL 27-02-07 10 Please note the - ED810 EC- TYPE EXAMINATI O N CE RTIFICATE And the ZB EC-TYPE EXAMIN ATION CERTIFICA TE Graphics have been rem oved t o reduc e the size of the d ocument for download pu rposes. The full manual and certificates can be ob tained by contacting Ele ctronic Devices ltd.[...]