B&B Electronics DTB Series manual

1
2
3
4
5
6
7
8
9
10
11
12
13

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of B&B Electronics DTB Series, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of B&B Electronics DTB Series one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of B&B Electronics DTB Series. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of B&B Electronics DTB Series should contain:
- informations concerning technical data of B&B Electronics DTB Series
- name of the manufacturer and a year of construction of the B&B Electronics DTB Series item
- rules of operation, control and maintenance of the B&B Electronics DTB Series item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of B&B Electronics DTB Series alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of B&B Electronics DTB Series, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the B&B Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of B&B Electronics DTB Series.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the B&B Electronics DTB Series item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    http: //www.del ta.com .tw/i ndustr ialau tomation / DEL T A T emperature Controller DTB Series User Manual[...]

  • Page 2

    1 B Series Temperature Controller User Manual 1 Precaution DANGER! Caution! E lectric Shock! 1. Do not touch th e AC terminals w hile the power is sup plied to the controller to prevent an electric s hock. 2. Make sure pow er is disconnected while checking th e unit insi de. 3. The symbol indicates th at this Delta B S eries T emperature C ontrolle[...]

  • Page 3

    2 4 Specifica tions 5 T emperature Sensor T ype and T emperature Range Input T emperature Sensor T ype Register V alue LED Display T emperat ure Range 0~50mV Analog Input 17 -999 ~ 9999 4~20mA Analog Input 16 -999 ~ 9999 0~20mA Analog Input 15 -999 ~ 9999 0V~10V Analog Input 14 -999 ~ 9999 0V~5V Analog Input 13 -999 ~ 9999 Platinum Resistance (Pt10[...]

  • Page 4

    3 6 Operation There are three modes of operation: operation, regulation and in itial setting. When power is applied, controller gets into the operation mode. Press the key to switch to regulation mode. If the key is pressed for more than 3 seconds, c ontroller will switch to t he initial setting mode. Pressing the key while in the regulation mode o[...]

  • Page 5

    4 T ime setting for valve from full close to full open. (Displa y when valve cont r ol is ON) Pr ess D ispl ay and ad jus t out put va lu e of 1st o utp ut gr oup (Di s pla y in PID con tr ol mode and man ual RU N m o d e) Press ASCII, RTU com mun ication format select io n Press Pr e s s V alv e Dea d B and setti ng. Pr e s s (Di s pl ay wh en val[...]

  • Page 6

    5 7 Dual Loop Output Control (Heating / Cooling Contr ol) OF F PV Set p oint ON He atin g De ad ban d He ati n g h yst eresi s Fi gure 1. O utp ut d uri ng dua l l oo p out put con t ro l oper ation o f ON /OFF cont rol C ooli ng hy st er esi s Co oli ng PV 0 Out p u t De ad ba nd: de ad band width=pos itive Set p oint Heat in g C o oli ng Fi gure [...]

  • Page 7

    6 8 Alarm Output s There are up to three groups of alarm outputs and each group allows thirteen alarm types in the initial setting mode. The alarm output is activated whenever the process temperature value (PV) is getting higher or lo wer than the set point of alarm limit. Set Va l u e Alarm T ype Alarm Output Operation 0 Alarm function disabled Ou[...]

  • Page 8

    7 9 Current T ransformer (CT) Function The Current T ransformer ( CT) function is used with the alarm out put. When using a current transforme r (CT) with the controller , change the corresponding alarm output mode to mode 13 (alarm output set value is 13), then turn to operation mode and set the current lowe r-limit and current upper-limit. Y ou c[...]

  • Page 9

    8 13 RS-485 Communication 1. Supporting transmission speed: 2400, 4800, 9600, 19200, 38400bps 2. Non-supported formats: 7, N, 1 or 8, O, 2 or 8, E, 2 3. Communication protocol: Modbus (ASCII or RTU) 4. Function code: 03H to read the contents of register (Max. 8 wo rds). 06H to write 1 (one) word into register . 02H to read the bits data (Max. 16 bi[...]

  • Page 10

    9 1030H S tart pattern number 0 ~ 7 1040H~ 1047H Actual step number setting inside the correspond pattern 0 ~ 7 = N, indicate that this pattern is executed from step 0 to step N 1050H~ 1057H Cycle number for repeating the execution of the correspond pattern 0 ~ 99 indicate that this pattern has been executed for 1 ~ 100 times 1060H~ 1067H Link patt[...]

  • Page 11

    10 14 Panel Cutout and T erminals Identification  Panel Cutout ( dimensions are in millimeter and inch)  T ermi nals Identification DTB4824 65 .0 m in. (2. 56) 4 0 . 0 m i n . ( 1 . 5 8 ) 44 .8 (1. 76) 2 2 . 0 ( 0 .8 7 ) +0.6 -0 +0.02 -0 + 0 . 6 - 0 + 0 . 0 2 - 0 mm (in ) DTB4824 1 4 3 2 5 6 AC 100~ 240V 50/60 H z 5V A Tc + - RTD OU T 1 DA T [...]

  • Page 12

    11 15 External Dimensions Dim ensions are in millimeter (inch)  DTB4824  DTB4848 48.0 mm (1.89 in) 2 4 . 0 m m ( 0 . 9 4 i n ) 3.4 mm (0.13 in) 99.8 mm (3.93 in) 2 1 . 8 5 m m ( 0 . 8 6 i n ) 44.75 mm (1.76 in) 2 2 . 0 m m ( 0 . 8 7 i n ) 44.8 mm (1.76 in) 48.0 mm (1.89 in) 4 8 . 0 m m ( 1 . 8 9 i n ) 9.5 mm (0.37 in) 80.0 mm (3.15 in) 4 4 . [...]

  • Page 13

    12 16 Mounting Mounting Method Mounting Bracket Installation CT Wiring Method (if C T function is selected) S tep 1 : Insert t he controller through the panel cutout. S tep 2 : Insert t he mounting bracket into the mounting groove at th e top and bott om of the controller S tep 3 : Push the mounting bracket for ward until the bracket stops at p ane[...]