Bally High Profile Unit Cooler manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Bally High Profile Unit Cooler, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bally High Profile Unit Cooler one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Bally High Profile Unit Cooler. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Bally High Profile Unit Cooler should contain:
- informations concerning technical data of Bally High Profile Unit Cooler
- name of the manufacturer and a year of construction of the Bally High Profile Unit Cooler item
- rules of operation, control and maintenance of the Bally High Profile Unit Cooler item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bally High Profile Unit Cooler alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bally High Profile Unit Cooler, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bally service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bally High Profile Unit Cooler.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Bally High Profile Unit Cooler item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    High Profile Unit Cooler High & Medium T emper ature Air Defrost Bulletin B30-BHP A-PDI-50 1081587-50-1 PRODUCT DA T A & INST ALLA TION CONTENTS Page Nomenclature........................................................................................................................ 2 Features & Options...................................[...]

  • Page 2

    - 2 - ST ANDARD FEA TURES OPTIONAL FEA TURES • Heavy gauge textured aluminum cabinet with galvanized steel hangers, support channels and end plates • Hinged access panels with removable hinge pins and captive fasteners. • Hinged drain pan with removable hinge pins • Rugged heavy-gauge galvanized steel rail motor mount / support. • S tacka[...]

  • Page 3

    - 3 - CAP ACITY DA T A 50Hz High and Medium T emperature Models - Cap acity @ 7 F .P .I. A verage Air Throw - f t (m) † * Estimated, based on R404A at +25° S.S.T . with coil 30% full. Derate capacity by 0.92 and CFM by .85 for Throw Booster Option. ELECTRICAL DA T A NOTE: 3+ indicates 3-fan “long” configuration (see dimen- sional data for de[...]

  • Page 4

    - 4 - WIRING DIAGRAM[...]

  • Page 5

    - 5 - DIMENSIONAL DA T A 2 Fan Models 3 Fan Models Drain connections 1-1/4” FPT .[...]

  • Page 6

    - 6 - SPECIFICA TIONS DIMENSIONAL DA T A 3 Fan (Long) Models 4 Fan Models Drain connections 1-1/4” FPT . s l e d o M . p m e T m u i d e M / h g i HA H 3 7 0A H 6 8 0A H 3 1 1A H 0 3 1A H 4 5 1A H 0 7 1A H 9 8 1A H 3 3 2A H 2 5 2A H 8 7 2 s n a F f O r e b m u N 22 2 3 3 3 3 4 4 4 . n n o C r o t u b i r t s i D ) t a e w S D O ( s e h c n I ) m [...]

  • Page 7

    - 7 - INST ALLA TION INSTRUCTIONS MOUNTING This evaporator is supplied with shipping legs to allow units to be shipped in an upright position. Units can be lifted into place with shipping skid attached to mounting legs. Hanger brackets take up to 5/8” (15.9 mm) hanger rods. After the evaporator is hung in place, remove the bolts attaching the ski[...]

  • Page 8

    - 8 - INST ALLA TION INSTRUCTIONS (cont’d) PIPING Refrigerant line sizes are important and may not be the same size as the coil connections (depends on the length of run). If in doubt, consult “Recommended refrigerant line sizes” charts. WIRING Wire system in accordance with governing standards and local codes. Enclosed typical wiring diagram[...]

  • Page 9

    - 9 - SER VICE P ARTS LIST S R O T O MS L E D O M# T R A P P D O# T R A P C F E T 0 5 / 3 / 0 2 2 - 0 0 2 M P R 0 5 8 P H 10 3 1 , 6 8 0 , 3 7 07 3 7 0 8 0 11 4 7 0 8 0 1 0 5 / 3 / 0 2 2 - 0 0 2 M P R 0 4 1 1 P H 5 . 1 8 7 2 , 2 5 2 , 3 3 2 , 9 8 1 , 0 7 1 , 4 5 1 , 3 1 19 3 7 0 8 0 13 4 7 0 8 0 1 0 5 / 3 / 0 0 4 - 0 8 3 M P R 0 5 8 P H 10 3 1 , 6 [...]

  • Page 10

    - 10 - NOTES[...]

  • Page 11

    - 11 - FINISHED GOODS WARRANTY The terms and conditions as described below in the General W arranty Policy cover all products manufactured by National Refrigeration. GENERAL W ARRANTY POLICY Subject to the terms and conditions hereof, the Company warrants all Products, including Service Parts, manufactured by the Company to be free of defects in ma[...]

  • Page 12

    “AS BUIL T” SER VICE P ARTS LIST Service Parts List Service Parts List Service Parts List Service Parts List Service Parts List L L L L L abel abel abel abel abel T T T T T o Be A o Be A o Be A o Be A o Be A ttached ttached ttached ttached ttached HERE HERE HERE HERE HERE General Sales, P General Sales, P General Sales, P General Sales, P Gener[...]