Baldor MN806 manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Baldor MN806, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Baldor MN806 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Baldor MN806. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Baldor MN806 should contain:
- informations concerning technical data of Baldor MN806
- name of the manufacturer and a year of construction of the Baldor MN806 item
- rules of operation, control and maintenance of the Baldor MN806 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Baldor MN806 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Baldor MN806, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Baldor service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Baldor MN806.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Baldor MN806 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    SOLID ST A TE ST AR TER P AR TS BREAKDOWN BY PRODUCT LINE MN806 Printshop 2000 7/96[...]

  • Page 2

    T able of Contents Contr ol T ype . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section Dynamic Brakes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B Def inite Pur pose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D General Purpose [...]

  • Page 3

    B-1 B 7 1 C P Brake V oltage 7 - 208/230/460 V A C AMP Size 0 - 8 AMPS 1 - 16 AMPS 2 - 30 AMPS 3 - 55 AMPS 4 - 135 AMPS C - Control only Enclosure T ype A - Open B - NEMA 1 C - NEMA 12 D - NEMA 4 P - P ANEL Dynamic Brakes There are 2 styles of brakes b uilt by Baldor . V erify the type of brake first. Old Style The “old style” brake has most pa[...]

  • Page 4

    B-2 1 If the SCR/Diode are replaced an SCR kit is also required. A A Braking Module This module is not av ailable. If the module can not be repaired the brake must be replaced. Sizes 0, 1 and 2 hav e the SCRs in the module and can be replaced. Size 0, 1 and 2 D Braking Contactor Over a 15 year period se v eral brands of contactors ha ve been used. [...]

  • Page 5

    D-1 TYPE OF CONTROL D - Definite Purpose Control DEFINITE PURPOSE D 7 0 C A A Module (LCM) *TYPE SIZE AMP 60Hz 50Hz I 0,1,2 8,16,30 REPLA CE ENTIRE UNIT II 3,4 50,70 D8X D9X III, IV 3,4,5 50,70, L8X L9X 135 B SCR/Po wer Cell(s) C F ans D MO V -All Sizes E Thermostat F Line Load T erminals *TYPE SIZE AMP P AR T III, IV 3,4,5 50,70,135 TSW0010 INPUT [...]

  • Page 6

    D-2 Def inite Pur pose Contr ols Refer ence I II III IV OPEN 8-70 AMP NEMA 12/3R 135 AMP P ANEL AND NEMA 1 50 AND 70 AMP P ANEL AND NEMA 1 30 AMP 8 AND 16 AMP A B A C E B C A E F G F G F F E E E G F F[...]

  • Page 7

    G-1 G 7 6 A B T ype of Control G - General Purpose M - Multipurpose (Non UL) R - Ramp up / Ramp down V oltage Code 1 - 208 60Hz 2 - 230 60Hz 3 - 380 50Hz 4 - 400 50Hz 5 - 460 60Hz 6 - 575 60Hz 7 - 208/230/460 60Hz 8 - 230/460/575 60Hz 9 - 220/380 50Hz AMP Size G and R M AMP Rating 0A 8 1B 1 6 2C 3 0 3D 5 5 –E 8 0 4 F 135 5 G 250 6 H 400 7 J 700 G[...]

  • Page 8

    G-2 CT1 CT1 CT2 General Purpose/Ramp Up - Ramp Do wn and non UL V ersions of Multipurpose Contr ol Size 0, 1 Size 2 Size 3 Size 4, 5, 6, 7 F G A A G F F A K B D D J H G G G J C E E E F D D K A B J C H E G[...]

  • Page 9

    G-3 A Control Module The Control Module is no longer av ailable. The Multipurpose module can be used as a replacement. For sizes 0, 1, 2 (G and R controls), a replacement control is required. For sizes 4-7 and D-J a replacement module can be used. For 60Hz applications use the MB8X, and for 50Hz applications use the MB9X. A con version manual is in[...]

  • Page 10

    G-4 6 Po wer Cells and SCRs CONTR OL TYPE PO WER CELL REPLA CEMENT SCR AMP NON UL MAX SIZE G and R M V A C CA T . NO. CA T . NO. 8, 16 0, 1 A, B 460 – SCR0005 575 – SCR0010 30 20 C 466 – SCR0015 575 – SCR0020 55 3 D 460 PC1B SCR0025(3) 575 PC1B SCR0025(3) 80 – E 460 PC2B SCR0130(3) 575 PC2B SCR130(3) 135 4 ➀ F ➀ 460 PC4A SCR0055(2) 57[...]

  • Page 11

    G-5 K Control T ransf ormers Control T ransformers are locally av ailable. Baldor stocks simular transformers byt may require panel modification to f it. SIZE GENERAL RAMP NON UL UL PURPOSE UP/DO WN MUL TIPURPOSE MUL TIPURPOSE 0 G70** R70** MA7A** MA7-008-** 1 G71** R71** MA7B** MA7-016-** 2 G72** R72** MA7C** MA7-030-** 3 G73** R73** MA7D** MB7-05[...]

  • Page 12

    G-5 K Control T ransf ormers Control T ransformers are locally av ailable. Baldor stocks simular transformers byt may require panel modification to f it. SIZE GENERAL RAMP NON UL UL PURPOSE UP/DO WN MUL TIPURPOSE MUL TIPURPOSE 0 G70** R70** MA7A** MA7-008-** 1 G71** R71** MA7B** MA7-016-** 2 G72** R72** MA7C** MA7-030-** 3 G73** R73** MA7D** MB7-05[...]