Bacharach 19-7038 manual

1
2
3
4
5
6
7
8
9
10
11

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Bacharach 19-7038, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bacharach 19-7038 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Bacharach 19-7038. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Bacharach 19-7038 should contain:
- informations concerning technical data of Bacharach 19-7038
- name of the manufacturer and a year of construction of the Bacharach 19-7038 item
- rules of operation, control and maintenance of the Bacharach 19-7038 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bacharach 19-7038 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bacharach 19-7038, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bacharach service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bacharach 19-7038.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Bacharach 19-7038 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    DIOXOR II INSTRUCTION 19-9121 Portable SO 2 Analyzer Part No. 19-7038 & 19-7043 Rev . 5 - September 1997 ® Bacharach, Inc. 625 Alpha Drive, Pittsburgh, P A 15238 (412) 963-2157/2164 Fax: (412) 963-2640 Web: www .bacharach-inc.com Printed in U.S.A. ® Registered Trademarks[...]

  • Page 2

    WARRANTY Bacharach, Inc. warrants to Buyer that at the time of delivery this Product will be free from defects in material and manufacture and will conform substantially to Bacharach Inc.’s applicable specifications. Bacharach’s liability and Buyer’s remedy under this warranty are limited to the repair or replacement, at Bacharach’s option,[...]

  • Page 3

    1 WARNING! Because this instrument is used to detect and monitor materials and conditions which are listed by OSHA or others as potentially hazardous to personnel and property, the information in this manual must be fully understood and utilized to ensure that the instrument is operating properly and is both used and maintained in the proper manner[...]

  • Page 4

    2 Figur e 2. Battery Installation 2 TECHNICAL CHARACTERISTICS SO 2 Display Range ........... 0-1999 ppm SO 2 Accuracy ........................... ±10 ppm or ±5% of reading whichever is greater Response Time ................. 90% of final value within 40 sec. Battery Requirements ....... 1.5 V, “C” cells, Qty. 4 Operating Time* ...............[...]

  • Page 5

    If batteries are accidently installed in the wrong polarity, a positive temperature coefficient (PTC) thermistor will protect the instrument’s electronic circuity. The instrument will operate once batteries are properly installed and the PTC thermistor is allowed to cool. 3.2 Probe Installation The probe comes disassembled. To add the probe tip: [...]

  • Page 6

    4 4 OPERATION To operate the Dioxor II, you simply . . . • Set its POWER switch to ON, • Wait for the instrument to warm up (approx. 1 minute), • Zero the display (if necessary), • Take a gas sample. Detailed operating procedures are presented below: 4.1 Power ON/OFF Turn on the instrument by sliding its POWER switch to ON. Observe that whe[...]

  • Page 7

    5 The instrument's elastic strap allows the unit to be either hand-held, or hung on nearby objects. By sliding your hand between the instrument and its elastic strap, you can hold onto the Dioxor II with a minimum of effort. The instrument's front panel slide switches can then be actuated by your thumb for one- Important: If condensation [...]

  • Page 8

    6 Overrange When the gas sample exceeds 1999 ppm, a “1” is displayed on the LCD. To clear an overrange con- dition, leave the instrument turned on and sample fresh air until the LCD returns to displaying SO 2 . Low Battery Indications When the battery voltage becomes low, the “LO BAT” indicator appears. Although the instrument will continue[...]

  • Page 9

    6 PARTS/SERVICE 6.1 Parts List Item Part No. Battery Cover 19-3029 Probe/Hose Assy. 19-3076 6.2 Bacharach Sales/Service Centers United States Bacharach S/S Center 625 Alpha Drive Pittsburgh, PA 15238 (412) 963-2164/2157 (412) 963-2640 FAX Bacharach S/S Center 8618 Louisiana Place Merrillville, IN 46410 (219) 736-6178 (219 736-6269 FAX Bacharach S/S[...]

  • Page 10

    7 HAZARDS OF SULFUR DIOXIDE Properties: Sulfur dioxide (SO 2 ) is a colorless, nonflammable gas that has a strong pungent odor, is twice as heavy as air, and is highly corrosive to ordinary metals when mixed with water vapor. Physiological Effects: Exposure to sulfur dioxide gas in low concentrations produces an irritating affect on the mucous memb[...]

  • Page 11

    First Aid: Move victims to fresh air. If breathing has ceased, begin artificial respiration immediately. Administer oxygen if exposure has been severe and breathing is difficult. Seek medical attention immediately. References: [1] Code of Federal Regulations , Title 29 CFR Parts 1900-1910 (Labor), Superintendent of Documents, U.S. Government Printi[...]