Aurora 341A manual

1
2
3
4
5
6
7
8
9
10

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Aurora 341A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Aurora 341A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Aurora 341A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Aurora 341A should contain:
- informations concerning technical data of Aurora 341A
- name of the manufacturer and a year of construction of the Aurora 341A item
- rules of operation, control and maintenance of the Aurora 341A item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Aurora 341A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Aurora 341A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Aurora service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Aurora 341A.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Aurora 341A item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    INSTRUCTION AND REP AIR MANUAL MODELS 341A, 342A AND 344A 6 SECTION 6 ITEM 340 DATED JUNE 1998 SUPERSEDES ITEMS 341, 342, 344 DATED MARCH 1992 © 1992 AURORA PUMP NO. AURORA, ILLINOIS NOTE This repair manual is applicable to pump Models 341A, 342A and 344A. All photos illustrate Model 344A. A TTENTION: SAFETY W ARNINGS : Read and understand all war[...]

  • Page 2

    MODELS 341A-342A-344A 2 grease is recommended as lubricants for pumps operating in both wet and dry locations. Mixing of different brands of grease should be avoided due to possible chemical reactions between the brands which could damage the bearings. Accordingly , avoid grease of vegetable or animal base which can develop acids, as well as grease[...]

  • Page 3

    MODELS 341A-342A-344A 3 DISASSEMBL Y Disassemble only what is needed to make repairs or accomplish inspection. (See Figure 2 for Model 341A, Figure 3 for Model 342A and Figure 3 for Model 344A.) 1. Disconnect and lockout power source to prevent drive unit from being energized during disassembly . 2. Unscrew the two drain plugs (4) from the casing ([...]

  • Page 4

    MODELS 341A-342A-344A 4 13. The seal flexible cup and stationary seat should be pressed out of the bracket (35) and the cavity cleaned of all residue. Make sure that the 1/32 inch radius in the seal seat cavity is not damaged during disassembly since a sharp edge can eas- ily cut the flexible cup during reassembly . 14. On Model 344A pumps, remove [...]

  • Page 5

    MODELS 341A-342A-344A 5 Secure support (41) to bracket (35) with capscrews (39) and washers (40). Frame sizes 143 thru 184-JM Model 341A only . 7 . If nameplate (34) was removed, install and attach with screws (33). 8. W ipe the sealing faces of the seat and seal washer clean. Replace pin (61) in sleeve if it was removed during disas- sembly . Appl[...]

  • Page 6

    FLEXIBLE CUP ST A TIONAR Y SEA T W ASHER FLEXIBLE BELLOWS RET AINER DRIVE RING SPRING MODELS 341A-342A-344A 6 Figure 1. Mechanical Seal[...]

  • Page 7

    MODELS 341A-342A-344A 7 NOTES: 1. BRONZE FITTED CONSTRUCTION WILL BE FURNISHED AS ST ANDARD UNLESS SPECIFIED. 2. REFER TO F ACTOR Y FOR SPECIAL ALLOYS. 3. AURORA PUMP RESER VES THE RIGHT T O SUBSTITUTE MA TERIALS WITHOUT NOTICE 4. PIECE NUMBERS 14 AND 15 ARE NOT FURNISHED AS ST ANDARD, WHEN FUR- NISHED, IMPELLER MUST BE MODIFIED. 5. PIECE NUMBERS 3[...]

  • Page 8

    8 8 9 15 6 11 14 9A 41 35 33 34 32 27 25 61 16 5 2 3 39 9B 9C 3 4 1 7 12 10 40 4 MODEL 341A Figure 2. Model 341A Exploded View[...]

  • Page 9

    9 6 7 72 74 75 73 39 4 1 3 8 27 35 32 5 61 12 15 11 14 10 25 16 33 34 2 3 9B 9A 9C 9 4 MODEL 342A Figure 3. Model 342A Exploded View[...]

  • Page 10

    10 MODEL 344A 16 8 11 14 9A 9B 9C 7 15 27 25 61 12 10 49 52 50 55 42 54 57 64 2 3 5 35 63 62 39 60 33 46 56 51 47A 46 56 48 47 51A 53 41 40 44 59 58 59 9 6 1 3 4 34 32 4 59 43 Figure 4. Model 344A Exploded View AP-Sect.6-Item 340[...]