Audiovox PRO-9555 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Audiovox PRO-9555, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Audiovox PRO-9555 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Audiovox PRO-9555. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Audiovox PRO-9555 should contain:
- informations concerning technical data of Audiovox PRO-9555
- name of the manufacturer and a year of construction of the Audiovox PRO-9555 item
- rules of operation, control and maintenance of the Audiovox PRO-9555 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Audiovox PRO-9555 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Audiovox PRO-9555, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Audiovox service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Audiovox PRO-9555.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Audiovox PRO-9555 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Kit Contents (1) - Control Module (2) - 3 Button High Frequency Transmitters (1) - 3 Channel Code Learning Receiver (1) - Multi Pin Input/Output Harness (1) - Six Pin Power Harness (1) - Two Pin I/O Harness Factory Alarm By-Pass and Diesel Wait To Start Input (1) - 2 Pin Door Lock Harness (2) - 30 Amp In-line Fuse Holders With Fuses (1) - Control S[...]

  • Page 2

    The unit is designed for use with Automatic T ransmission V ehicles Only! The unit provides wait to start input for glow plug pre-heat which will be used for all diesel applications. If this wire is not connected, then the unit will remain in the Gasoline mode setting, which will crank the car when the RF signal is received with no delay . Regardle[...]

  • Page 3

    3 THE RECEIVER/ANTENNA ASSEMBL Y : The Superheterodyne Receiver Antenna Assembly provided with this unit allows routing from below the dashboard for maximum operating range. Choose a location above the belt line (dashboard) of the vehicle for best reception. Special considerations must be made for windshield glass as some newer vehicles utilize a m[...]

  • Page 4

    NOTE: This wire must be connected to the vehicle side of the starter cut relay (when used). For the electrical neutral switch configuration, this connection must be made between the starter inhibit relay , (when used) and the neutral safety switch as shown in the following diagram. Failure to connect this wire to the ignition switch side of the neu[...]

  • Page 5

    VIOLET WIRE: Accessory Output Connect this wire to the Accessory wire from the ignition switch. This wire will show + 12 volts when the ignition switch is turned to the "ACCESSORY" or "ON" and "RUN" positions and will show 0 volts when the key is turned to the "OFF" and "ST AR T" or "CRANK"[...]

  • Page 6

    BROWN w/ BLACK Tracer Wire: Positive Inhibit Input 2 Any time + 12 Volts is applied to the Brown w/ Black tracer wire, the Remote Starter will stop operating, even if the signal is received from the transmitter. If the brake light switch in the vehicle switches + 12 Volts to the brake light circuit, connect the Brown w/ Black trace wire to the outp[...]

  • Page 7

    LIGHT BLUE Wire: Ignition 3 / Shock Disable Output This wire provides a 300mA ground output that becomes active 3 seconds before the Remote Start Unit initializes, and remains grounded while running plus an additional 4 seconds after the Remote Start Unit turns off. In all of the applications described below , a relay will be required. The Light Bl[...]

  • Page 8

    General Motors V A TS By-Pass Diagram DARK GREEN Wire: T ach Sensor Input This wire will continually monitor the engine tach rate while the unit is under power of the Remote Start module. This wire will be routed to the vehicle ECM tach input or through the firewall into the engine compartment and connect to the negative side of the ignition coil. [...]

  • Page 9

    3 Wire Ground Switched Door Lock/Unlock Wiring Detail 3 Wire Positive Switched Door Locks: In this application, the Red wire of the two pin harness provides a + 12 volt pulse during the disarming sequence, or pulsed 12 volt unlock output. Connect the Red wire to the low current 12 volt signal wire from the factory door unlock switch to the factory [...]

  • Page 10

    10 this wire is not used. Be sure to fuse the wire with a 1 Amp Fuse when connecting to a high current circuit such as a factory glow plug wire. The fuse should be installed as close to the high current wire as possible. 3 Pin Antenna/Receiver Connector: (White Connector) Plug the previously routed three pin connector from the antenna receiver asse[...]

  • Page 11

    11 3. Diagnostics: 1. Be sure that programmable feature number #6 is set to the "Diagnostics On" mode. 2. First flip the program switch on, then turn the ignition key to the "ON" position. 3. The lights will flash and the number of flashes will indicate the reason for shutdown on the last remote start attempt. The indications ar[...]

  • Page 12

    W ARNING!! DO NOT RELEASE THIS VEHICLE TO THE CONSUMER UNTIL YOU CONFIRM THE OPERA TION OF THE HOOD PIN SAFETY SHUT DOWN FEA TURE. MANUAL SHUT DOWN / ENABLE CIRCUIT : The intent of the manual shut down / enable circuit is to allow the vehicle operator to prevent operation of the Remote Start Unit regardless of the RF transmitter operation. T o test[...]

  • Page 13

    13 from the ignition cylinder . This configuration prevents mechanical operation while the vehicle is in gear but offers no consideration for electrical operation. Because of this potential problem, this installation requires the additional connection of a safety wire from the remote start device to the vehicle Park/Neutral ECM Input or the vehicle[...]

  • Page 14

    14 Method 2 will allow the safety required for the remote start unit and prevent the vehicle from starting while in any gear other than Park or Neutral while the key is in the ignition cylinder . However , the original factory key in chime module will not alert the owner that the key has been left in the ignition switch. In addition, this may also [...]

  • Page 15

    15 NOTE: A second 4002 series diode may be required to maintain the integrity of the hood open, shut down circuit. If this is the case, it must be installed as shown in the diagram above. The anode (Non Striped) side must be connected to the Gray/Black wire of the Remote Start Unit. The cathode (Striped) side must be connected to the hood pin switc[...]

  • Page 16

    © 2001 Audiovox Electronics Corp., Hauppauge, NY 1 1788 128-6138 PRO-9555[...]