Audiovox PRO-9555 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Audiovox PRO-9555, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Audiovox PRO-9555 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Audiovox PRO-9555. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Audiovox PRO-9555 should contain:
- informations concerning technical data of Audiovox PRO-9555
- name of the manufacturer and a year of construction of the Audiovox PRO-9555 item
- rules of operation, control and maintenance of the Audiovox PRO-9555 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Audiovox PRO-9555 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Audiovox PRO-9555, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Audiovox service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Audiovox PRO-9555.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Audiovox PRO-9555 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    128-6507 1 of 16 Kit Contents (1) - Control Module (2) - 3 Button High Frequency Transmitters (1) - 3 Channel Code Learning Receiver (1) - Multi Pin Input/Output Harness (1) - Six Pin Power Harness (1) - Two Pin I/O Harness Factory Alarm By-Pass and Diesel Wait To Start Input (1) - 2 Pin Door Lock Harness (2) - 30 Amp In-line Fuse Holders With Fuse[...]

  • Page 2

    128-6507 2 of 16 This Remote Start/Keyless Entry System is designed for use with Automatic T ransmission V ehicles Only! The unit provides wait to start input for glow plug pre-heat which will be used for all diesel applications. If this wire is not connected, then the unit will remain in the Gasoline mode setting, which will crank the car when the[...]

  • Page 3

    128-6507 3 of 16 3 THE RECEIVER/ANTENNA ASSEMBL Y : The Superheterodyne Receiver Antenna Assembly provided with this unit allows routing from below the dashboard for maximum operating range. Choose a location above the belt line (dashboard) of the vehicle for best reception. Special considerations must be made for windshield glass as some newer veh[...]

  • Page 4

    128-6507 4 of 16 NOTE: This wire must be connected to the vehicle side of the starter cut relay (when used). For the electrical neutral switch configuration, this connection must be made between the starter inhibit relay , (when used) and the neutral safety switch as shown in the following diagram. Failure to connect this wire to the ignition switc[...]

  • Page 5

    128-6507 5 of 16 VIOLET WIRE: Accessory Output Connect this wire to the Accessory wire from the ignition switch. This wire will show + 12 volts when the ignition switch is turned to the "ACCESSORY" or "ON" and "RUN" positions and will show 0 volts when the key is turned to the "OFF" and "ST ART" or [...]

  • Page 6

    128-6507 6 of 16 BROWN w/ BLACK Tracer Wire: Positive Inhibit Input 2 Any time + 12 Volts is applied to the Brown w/ Black tracer wire, the Remote Starter will stop operating, even if the signal is received from the transmitter. If the brake light switch in the vehicle switches + 12 Volts to the brake light circuit, connect the Brown w/ Black trace[...]

  • Page 7

    128-6507 7 of 16 LIGHT BLUE Wire: Ignition 3 / Shock Disable Output This wire provides a 300mA ground output that becomes active 3 seconds before the Remote Start Unit initializes, and remains grounded while running plus an additional 4 seconds after the Remote Start Unit turns off. In all of the applications described below , a relay will be requi[...]

  • Page 8

    128-6507 8 of 16 Green/Orange Wire: T ach Sensor Input This wire will continually monitor the engine tach rate while the unit is under power of the Remote Start module. This wire will be routed to the vehicle ECM tach input or through the firewall into the engine compartment and connect to the negative side of the ignition coil. This Remote Start u[...]

  • Page 9

    128-6507 9 of 16 NOTE: The outputs above are low current outputs and must be used with a relay if the circuit's requirement is more than 300 mA. 2 Pin Door Lock/Unlock Harness: (White Connector) The Red & Green Door Lock/Unlock output wires provide either a pulsed ground or pulsed + 12 volts to control the vehicle door lock / unlock circui[...]

  • Page 10

    128-6507 10 of 16 10 Resistive Circuits, As W ell As 4 W ire Polarity Reversal and 5 W ire Alternating 12 V olt Door Lock Control Circuits These applications require the use of additional components which may include relays, fixed resistors, or for convenience, the AS 9159 Door Lock Interface. Refer to the AUDIOVOX Door Lock Wiring Supplement and o[...]

  • Page 11

    128-6507 11 of 16 11 4. Hold the program switch ON, then start the vehicle using the ignition key . 5. When the unit senses the tach signal, the parking lights will begin to flash. 6. Release the program switch. The parking lights will turn on for 3 seconds to indicate that the tach signal is stored and the unit is now out of the program mode. 3. D[...]

  • Page 12

    128-6507 12 of 16 2. Reach inside the car and pull the hood release. 3. Raise the hood and confirm that the remote start unit shuts down. If the unit fails this test, recheck your pin switch connection to the Gray/Black wire of the Audiovox Remote Start Unit. W ARNING!! DO NOT RELEASE THIS VEHICLE TO THE CONSUMER UNTIL YOU CONFIRM THE OPERA TION OF[...]

  • Page 13

    128-6507 13 of 16 MECHANICAL NEUTRAL SAFETY SWITCH CONSIDERA TIONS: Mechanical neutral safety switch configurations differ slightly in that they do not offer the same level of safety when installing a remote start device. Often when the ignition switch is turned off while the gear selector is in any position other than park or neutral, the mechanic[...]

  • Page 14

    128-6507 14 of 16 NOTE: A second 4002 series diode may be required to maintain the integrity of the hood open, shut down circuit. If this is the case, it must be installed as shown in the diagram above. The anode (Non Striped) side must be connected to the Gray/Black wire of the Remote Start Unit. The cathode (Striped) side must be connected to the[...]

  • Page 15

    128-6507 15 of 16 NOTE: A second 4002 series diode may be required to maintain the integrity of the hood open, shut down circuit. If this is the case, it must be installed as shown in the diagram above. The anode (Non Striped) side must be connected to the Gray/Black wire of the Remote Start Unit. The cathode (Striped) side must be connected to the[...]

  • Page 16

    128-6507 16 of 16 © 2003 Audiovox Electronics Corp., Hauppauge, NY 1 1788 1286507[...]