ATS HILT 9000 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of ATS HILT 9000, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of ATS HILT 9000 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of ATS HILT 9000. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of ATS HILT 9000 should contain:
- informations concerning technical data of ATS HILT 9000
- name of the manufacturer and a year of construction of the ATS HILT 9000 item
- rules of operation, control and maintenance of the ATS HILT 9000 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of ATS HILT 9000 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of ATS HILT 9000, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the ATS service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of ATS HILT 9000.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the ATS HILT 9000 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    HIL T 9000 Handheld Inductive Loop T ester User Manual July 2003 R=12.3 Ω Q=12.1 L=89.2µH 50KHz ATSI 8157 US Route 50 • Athens, OH 45701 (740) 592-2874 • Fax (740) 594-2875 sales@atsi-tester .com www.atsi-tester .com[...]

  • Page 2

    1 HILT 9000 - Inductive Loop Tester T able of Contents Receiving Y our Shipment ......................................................... 2 Packaging ..... ........................................................................... 2 Description ............................................................................. 3 Overview of HIL T 9000 C[...]

  • Page 3

    2 www.atsi-tester .com W a r nings These safety war ning are provided to ensure the safety of personnel and proper operation of the tester . • The tester must not be operated beyond its specified operating range. • Safety is the responsibility of the operator . Receiving your Shipment Upon receiving your shipment, be sure that the contents are [...]

  • Page 4

    3 HILT 9000 - Inductive Loop Tester General Description The HILT -9000 is designed to measure characteristics of an inductive loop at dif ferent frequencies; measure working parameters of the loop system; as well as simulate the detector by measuring the change of inductance. The measurement modes can be easily switched by pressing corresponding bu[...]

  • Page 5

    4 www.atsi-tester .com Overview of HIL T 9000 Contr ols 1. LOOP: Measures R DC , L, and Q . If Q >15, use Q push- button to obtain actual value. 2. Q : Measures high Q values (when Q is >15). 3. Used in SET FREQ mode to increase frequency by 1KHz. 4. Used in SET FREQ mode to decrease frequency by 1KHz. 5. POWER: Tur ns unit On/Off. 6. SET FRE[...]

  • Page 6

    5 HILT 9000 - Inductive Loop Tester Function Controls Power Press the POWER push-button to tur n the tester on and off. The tester per for ms an initial self-test to verify that the inter nal circuit is working. After the self-test is complete, the tester shows the current battery level and the message: Ready: Select Function . If the battery is lo[...]

  • Page 7

    6 www.atsi-tester .com The LOOP test can measure a maxi- mum Q of 15. If Q is greater than 15 the tester displays Q >15 . To measur e the actual value, press the Q button on the keypad to run a separate Q test. The default frequency at which the LOOP and Q tests run is 50 KHz. It can be changed to any value within the range from 20 KHz to 80 KHz[...]

  • Page 8

    7 HILT 9000 - Inductive Loop Tester , , Set Frequency When the tester is powered, the test frequency is automatically set to 50 KHz. The frequency can be changed to any value between 20 KHz and 80 KHz with 1 KHz resolution. T o set a dif ferent fr equency press the SET FREQ push-button to view the fre- quency adjustment display as show in Figure 5.[...]

  • Page 9

    8 www.atsi-tester .com If there is bad connection, the tester displays a message as shown in Figure 7. Make sure that the test leads are properly connected. If the leads are connected to the loop and the message is still present, it means that Q of the loop is too low to generate the oscilla- tion or the inductance is out of range. This can be veri[...]

  • Page 10

    9 HILT 9000 - Inductive Loop Tester Function Controls Summary BUTTON DESC RIPTIO N COMMENTS LOOP Used to measure L, Q, and R DC of the loop. Q is measured up to 15. If Q> 15, use Q butt on to obtain th e actual v alue of Q The loop must be disconnected fro m the system to run th is test Q Used to m easure hig h Q values ( when Q is >15) The l[...]

  • Page 11

    10 www.atsi-tester .com Overview of T raf fic Loop Detection Systems The inductive loop represents the most commonly used method to detect vehicles. The inductive loop is simply a coil of wires embedded into the pavement and can be characterized by several parameters, L (inductance), Q (quality factor), R (active resis- tance, measured using AC sig[...]

  • Page 12

    11 HILT 9000 - Inductive Loop Tester To guarantee a reliable oscillation in the loop system the quality factor ( Q ) of the loop with the lead-in wires should be above some value, deter mined by the amplifiers inside the detector . Deterio- ration of the loop and lead-in wires reduces Q and eventually prevents the system from oscillating even with [...]

  • Page 13

    12 www.atsi-tester .com Commonly Asked Questions Q . Why do I have to disconnect the detector from the loop before running a Loop , Q , or ∆ ∆ ∆ ∆ ∆ L test? A. During Loop, Q , and ∆ L test, the tester is applying its own signal to the loop. The tester verifies there is no signal on the loop before running these tests. However , with a [...]

  • Page 14

    13 HILT 9000 - Inductive Loop Tester Repair and Calibration To ensure that your instrument meets factory specifications, we recommend that it be retur ned to our factory at one-year intervals for calibration service. In addition to calibration of the test parameters, this service includes replacement of batteries and fir mware updates. Please conta[...]

  • Page 15

    14 www.atsi-tester .com T echnical and Sales Assistance If you are experiencing any technical problems, or require any assistance with the proper operation or application of your tester , please call, fax, or e-mail our technical support staf f: ATSI 8157 US Route 50 • Athens, OH 45701 (740) 592-2984 (740) 594-2875 - Fax service@atsi-tester .com [...]

  • Page 16

    15 HILT 9000 - Inductive Loop Tester -- This page left blank --[...]

  • Page 17

    16 www.atsi-tester .com Limited W arranty The HIL T 9000 (“Product”), distributed by Athens Technical Specialists, Inc. (ATSI), is warranted to the original purchaser (“Purchaser”) to be free of defects in materials and workmanship for a period of one year from the purchase date stated on the invoice. Within this period, in the event of a d[...]