Ariston GL 4 manual

1
2
3
4
5
6
7
8
9
10
11

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Ariston GL 4, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Ariston GL 4 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Ariston GL 4. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Ariston GL 4 should contain:
- informations concerning technical data of Ariston GL 4
- name of the manufacturer and a year of construction of the Ariston GL 4 item
- rules of operation, control and maintenance of the Ariston GL 4 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Ariston GL 4 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Ariston GL 4, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Ariston service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Ariston GL 4.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Ariston GL 4 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Mini T ank water heater Electric under sink W ater heater s GL 2.5 - GL 4 - GL 6+[...]

  • Page 2

    The installer should revie w the contents of this manual with the owner upon completion of installation, and the manual should be left with the owner and placed in a location close to the installation. IMPOR T ANT SAFETY INSTR UCTIONS When using electrical appliances, safety precautions to reduce the risk of fire, electric shock or injury to person[...]

  • Page 3

    T emperature & pressure relief valve, 3/4 NPT male T emperature & pressure relief valve, 3/4 NPT male 3/4 NPT female tapping for relief valve 3/4 NPT female tapping 3/4 NPT female tapping 3/4 NPT female tapping for relief valve Hot water outlet 1/2 NPT male 3/4 NPT female tapping for relief valve FIG. 1/1 T emperature & pressure relief [...]

  • Page 4

    FIG. 2/1 DIMENSIONS FOR GL 2.5 - GL 4 DIMENSIONS FOR GL 6+ (HORIZONT AL INST ALLA TION) DIMENSIONS FOR GL 6+ (VERTICAL INST ALLA TION) FIG. 2/2 FIG. 2/3 5 GL 2.5 GL 4 14” 10 1/4” 12 1/4” 7 1/2” 3” 6” 3 1/2” 1” 14” 5 1/2” 3 3/4” 2 1/2” 14 1/2” 8 1/2” 4 1/2” 17 1/2” 14 1/2” 8 1/2” 4 1/2” 11 1/2” 17 1/2” 17 1/[...]

  • Page 5

    General remarks The manuf acturer cannot be responsible f or the damages caused by improper installation or by f ailure to follo w instructions in this pamphlet. Comply with the installation instructions before completing electric connection. The thermostat has been pre-set at the factory between 41°C (105° F) and 45° C (113° F). Hydrogen gas c[...]

  • Page 6

    Heater can sit on floor . Connect the cold water inlet pipe to the inlet nipple (marked with a b lue ring) and the hot water outlet pipe to the outlet nipple (marked with a red ring). T o reduce the r isk of e xcessive pressures and temperatures in this w ater heater , install the supplied temperature and pressure protectiv e equipment required by [...]

  • Page 7

    Maintenance instructions Note: Do not attempt to repair this water heater your self. Call a service person for assistance. Al ways turn off the power suppl y to the heater prior to servicing or draining the heater . PERIODIC MAINTENANCE AND P ARTS REPLA CEMENT Note: For most of these operations, the water will have to be drained from the heater . F[...]

  • Page 8

    Occasionally , the high temperature limit shut off de vice may trigger and shut the system down. This occurs when water temperature exceeds 190° F and shuts off power to the heating element. The shut off device ma y also trigger from a power outage or electrical stor m. T o reset: 1) IMPORT ANT: Disconnect heater from electrical power . 2) Remove [...]

  • Page 9

    10 G N FIG. 3/1 FIG. 3/2 FIG. 3/3 FIG. 3/4 FIG. 3/5 G Z F X Y T V C D B F W[...]

  • Page 10

    ARIST ON • LIMITED 6 YEARS W ARRANTY CO VERA GE ARIST ON, THROUGH ITS U.S . DISTRIBUTOR CONTROLLED ENERGY CORP ., (hereinafter CEC) guarantees this water heater to the Owner (hereinafter “Owner”) of the w ater heater at the original installation location against defects in material and workmanship f or the periods specified below . W ARRANTY [...]

  • Page 11

    MTS MAKES USE OF RECYCLED P APER 29.1.60.542.1.01 0900 Litograf s .r .l. Controlled Energy Cor p . 340 Mad Riv er Park W aitsfield, VT 05673 800-642-3111 802-496-4436 F ax 802 496-6924 www .controlledenergy .com COMMON SENSE HEA T & HO T W A TER TECHNOLOGY Merloni T ermoSanitari SpA Viale Aristide Mer loni, 45 60044 F abr iano (AN) T el. 0732.6[...]