APC SURT6000RMXLI-BNDL manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of APC SURT6000RMXLI-BNDL, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of APC SURT6000RMXLI-BNDL one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of APC SURT6000RMXLI-BNDL. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of APC SURT6000RMXLI-BNDL should contain:
- informations concerning technical data of APC SURT6000RMXLI-BNDL
- name of the manufacturer and a year of construction of the APC SURT6000RMXLI-BNDL item
- rules of operation, control and maintenance of the APC SURT6000RMXLI-BNDL item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of APC SURT6000RMXLI-BNDL alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of APC SURT6000RMXLI-BNDL, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the APC service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of APC SURT6000RMXLI-BNDL.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the APC SURT6000RMXLI-BNDL item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    User Manual English Smart-UPS ® RT 3000/5000/6000 VA 200-240 Vac Tower/Rack Mount 3U Uninterruptible Power Supply   © 2012 APC by Schneider Electric. APC, the APC logo, and Sm art-UPS are owned by Schneider Electric Industries S.A.S., American Power Conversion Corporation, or affiliated companie s. All other trademarks are th e property of [...]

  • Page 2

    [...]

  • Page 3

    Introduction The APC  by Schneider Electric Smart-UPS  RT is a high-performance, uninterruptible power supply (UPS) that provides protection for electronic equipment from utility power blackouts, brownouts, sags and su rges. The UPS filters small utility line fluctuatio ns and isolates electronic equipment from large disturbances by internall[...]

  • Page 4

    Wiring and Connecting the UPS 5000/6000 VA XLI MODEL S O NLY : H ARDWIRING I NSTRUCTI ONS  Wi ring must be performe d by a qualified electrician.  Install a high magnetic 30/32 A utility circuit breaker.  Adhere to all national and local electrical codes.  Use #10 AWG ga uge (5 mm 2 ) wire. 1. Switch the utility circuit breaker OFF. 2. [...]

  • Page 5

    C ONNECTING THE B ATTERY MODULES AND A TTACHING THE F RONT B EZEL     . 3[...]

  • Page 6

    B ASIC C ONNECTORS serial com Power m anagement software and interface kits can be used with the UPS. Use only inter face kits supplie d or approved by APC. Any other serial interface cable w ill be incompat ible with the UPS connector. normal bypass M anual bypas s enables the us er to manual ly put connecte d equipm ent into bypass m ode. EPO ter[...]

  • Page 7

    C ONNECTING E QUIP MENT AND P OWER TO THE UPS 1. Connect equipment to th e UPS (cables not included for XLJ/XLT/XLTW models). 2. Avoid using extension cor ds.  3000 VA XLJ/XLT/XLTW/XLI and 5000/6000 VA XLJ/XLT/XLTW models : Using a power cord, plug the UPS into a two-pole, three-wire, grounded receptacle only.  500 0/6000 VA XLJ and 6000 VA X[...]

  • Page 8

    O PERA TION Load S MART -UPS RT F RONT D ISPLAY Battery Charge Indicator Description Online The Online LED illuminates when the UPS is drawing utility power and performing double con version to su pply power t o connected eq uipment. On Battery The UPS is supplying batter y powe r to the connected equipment. Bypass The Bypass LED illuminates indica[...]

  • Page 9

    Feature Function Cold Start When there is no utility power and th e UPS is off, press and hold the button to power up t he UPS and conn ected equipm ent. The UPS will emit two beeps. During th e seco nd beep, release the button. Self-Test Automa tic: The UPS performs a self-test automa tically when turn ed on, and every two weeks thereafter (by def[...]

  • Page 10

    U SER C ONFIGURABLE I TEMS N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HUTE SOFTWARE OPTIONAL S MART S LOT ACCESSORY CARDS OR T ERMINAL M ODE . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Automatic Self-Test Every 14 days (336 hours) Every 7 days(168 hours), 14 days (336 hours) On Startup Only, No Self-Test Set the [...]

  • Page 11

    N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HUTE SOFTWARE OPTIONAL S MART S LOT ACCESSORY CARDS OR T ERMINAL M ODE . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Low Bypass Point -30% of output voltage setting -15%, -20%, -25%, -30% Minimum voltage that the UPS will pass to connected equipment during internal bypass [...]

  • Page 12

    Bo th Class 2 and SELV circuits must be isolated from all primary circu itry. D o not connect any circuit to the EPO terminal block unless it can be confirmed that the circuit is Class 2 or SELV. If circuit standard cannot be c onfirmed, use a contact closure switch. Use one of the following ca ble types to connect the UPS to the EPO s witch:  C[...]

  • Page 13

    5000/6000 VA models: Terminal Mode is a me nu driven interface that enables enhanced confi guration of the UPS. Connect the serial cable to the se rial port on the back of the UPS. 1. Open a term inal program . Example: Hy perTerminal  From the Desktop, go to Start => Programs => Accessories => Com munication => HyperTerminal. 2. Dou[...]

  • Page 14

    M AINTENANCE AND T RANSPORT Replacing the Battery Module This UPS has an easy to repla ce, hot-swappabl e battery modul e. Replaceme nt is a safe proce dure, isolated from electrical hazards. You may leave the UPS and connected eq uipm ent on during the procedure. See your dealer or contact APC at the Web site, www.apc.com for information o n repla[...]

  • Page 15

    R EPLACING B ATTERY MODULES          Disconnecting the Battery for Transport Always DISCONNECT THE BA TTERY(s) before shipping in compliance with U.S. Department of Tr ansportation (D OT) and IATA re gulations. The battery(s) may remain in the UPS. 1. Shut down and disconnect any equipm ent attached to the UPS. 2. Shut do[...]

  • Page 16

    T ROUBLESHOOTING , S ER VICE , AND W AR RANTY I NFORMA TION Use the table below to solve minor installation and operation problems. Refer to the APC Web site, www.apc.com for assistance with complex UPS problems. P ROBLEM AND P OSSIBLE C AUS E S OLUTION UPS WILL NOT TURN ON Battery not connected properly. Check that the battery connectors are fully[...]

  • Page 17

    P ROBLEM AND P OSSIBLE C AUS E S OLUTION BYPASS LED ILLUMINATES The bypass switch has been turned on manually or through an accessory. If bypass is the chosen mode of ope ration, ignore the illuminated LED. If bypass is not the chosen mode of operation move the bypass switch on the back of the UPS, to the normal position. FAULT AND OVERLOAD LED S I[...]

  • Page 18

    Service If the UPS requires service do not return it to the dealer. Follow these step s: 1. Review the pr oblems discusse d in the Trou bleshooting secti on of this manual to eliminate common pr oblems. 2. If the pro blem persists, cont act APC Custom er Support through t he APC Web site, ww w.apc.com .  Note the m odel number of the UPS, the se[...]

  • Page 19

    . 17 R EGULA TOR Y Radio Frequency Warnings This equipment has been tested and found to comply with the li m its for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable pr otection against harmful interf erence when the equipment is operated in a commercial environment. T his equipment gen[...]