APC SMT3000RMI2U-BNDL manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of APC SMT3000RMI2U-BNDL, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of APC SMT3000RMI2U-BNDL one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of APC SMT3000RMI2U-BNDL. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of APC SMT3000RMI2U-BNDL should contain:
- informations concerning technical data of APC SMT3000RMI2U-BNDL
- name of the manufacturer and a year of construction of the APC SMT3000RMI2U-BNDL item
- rules of operation, control and maintenance of the APC SMT3000RMI2U-BNDL item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of APC SMT3000RMI2U-BNDL alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of APC SMT3000RMI2U-BNDL, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the APC service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of APC SMT3000RMI2U-BNDL.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the APC SMT3000RMI2U-BNDL item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Oper at ion Ma nual Smart-UPS™ Uninter ruptible Power Suppl y Rack -Mount 2U 750/1000/1 500 V A 120/230 V ac 2200 V A 120 V ac 3000 V A 100/120/ 208/230 V ac[...]

  • Page 2

    1 Smart-UPS Rack- M ou nt2U 750/1000/15 00 VA 1 20/230 Vac, 3000 VA 100/ 120/208/230 Vac , 2 200 VA 120 Vac Prod uc t Description The APC ™ by S chneide r Ele ctric Smart-UPS ™ is a high performa nce uninterr uptible p ower supply (UPS). The UPS provide s protecti on for electron ic equipme nt from utilit y p ower blackout s, brownouts , sags, [...]

  • Page 3

    Smart-UPS Rack-Mou nt2U 750/1000/150 0 VA 12 0/230 Vac, 3000 VA 100/12 0/208/230 Vac, 2200 VA 120 Vac 2 Fron t and Rear Panel Feat ures Front panel fea tures Rear p anel f eatu res 1 Bat tery 2 Batte ry conn ector 3 Displa y inter face 4 Bezel 1 S mart Sl ot fo r o pt ion al NM C ac ces sor y ca rd 2 U PS input 3 Circuit brea ker/Ove rload protecti[...]

  • Page 4

    3 Smart-UPS Rack- M ou nt2U 750/1000/15 00 VA 1 20/230 Vac, 3000 VA 100/ 120/208/230 Vac , 2 200 VA 120 Vac S p ecifi cations For addi tional speci ficat ions, refer to the APC by Schnei der Ele ctric W eb si te at www .ap c.com. En vir onm ental Sp ec ific at ions Inst allation UPS For UPS ins tall ation inform ation , refer to the Sma rt-UPS I ns[...]

  • Page 5

    Smart-UPS Rack-Mou nt2U 750/1000/150 0 VA 12 0/230 Vac, 3000 VA 100/12 0/208/230 Vac, 2200 VA 120 Vac 4 Operat ion Conn ect Eq uipmen t to U PS Note: The UPS will cha rge to 90% capaci ty in the first thre e hours of normal opera tion. Do not expect full battery runtime capability during this initial charge period. 1. Connect equi pm e nt to the ou[...]

  • Page 6

    5 Smart-UPS Rack- M ou nt2U 750/1000/15 00 VA 1 20/230 Vac, 3000 VA 100/ 120/208/230 Vac , 2 200 VA 120 Vac Rear p anel c onnec tors Displa y Panel Feat ures Displa y Inter face M enus Use the UP / DOW N arrow keys to sc roll t hrough t he mai n menu o ptions . Pre ss ENTER to v iew the submenus under each main menu op tion. Press ESC APE t o exi t[...]

  • Page 7

    Smart-UPS Rack-Mou nt2U 750/1000/150 0 VA 12 0/230 Vac, 3000 VA 100/12 0/208/230 Vac, 2200 VA 120 Vac 6 St a ndard m enus The Standard menus are the most commonly us ed me nus for t he UPS . Me nu Ge neral Fu nction s St a t u s V i ew ba sic inf orma tion ab out th e UPS: • Ope rating mode • Eff icien cy of the U PS • Info rmati on about the[...]

  • Page 8

    7 Smart-UPS Rack- M ou nt2U 750/1000/15 00 VA 1 20/230 Vac, 3000 VA 100/ 120/208/230 Vac , 2 200 VA 120 Vac Ad van ced me nu s The Advan ced men us provide addi tiona l options for the UPS and ar e availabl e only if the dis play int erface is configu red to use the Adva nced menus. Menu General F unctions Sta tu s V iew d etai le d informat ion a [...]

  • Page 9

    Smart-UPS Rack-Mou nt2U 750/1000/150 0 VA 12 0/230 Vac, 3000 VA 100/12 0/208/230 Vac, 2200 VA 120 Vac 8 Config uration UP S Sett ing s St a rt up Settings Configure the se se ttings at i nitia l st art up, usin g the dis play i nterface or P owerChute ™ software. Note: During start u p, use the displ ay interfac e to configure t hese setti ngs. I[...]

  • Page 10

    9 Smart-UPS Rack- M ou nt2U 750/1000/15 00 VA 1 20/230 Vac, 3000 VA 100/ 120/208/230 Vac , 2 200 VA 120 Vac General Se ttings Configure the se sett ings at any ti m e , using the display inte rface or PowerChut e software. Function Factory Default Option s Descript ion High T ransf er Poi nt 100 V a c: 108 V a c • 108 V a c •1 1 0 V a c •1 1 [...]

  • Page 11

    Smart-UPS Rack-Mou nt2U 750/1000/150 0 VA 12 0/230 Vac, 3000 VA 100/12 0/208/230 Vac, 2200 VA 120 Vac 10 Date o f Last Battery Replac em e nt Date set at f actor y Res et th is dat e when t he batte ry mo dule i s repl aced . Audible Alarm On On/Off Th e UPS wil l mut e all au dibl e al arms i f thi s is set t o Off or when t he di splay ke ys ar e[...]

  • Page 12

    11 Smart-UPS Rack- Mount2U 750/1000 /1500 VA 120/230 Vac, 3 000 VA 100/120/208/ 230 Vac, 2200 VA 120 Vac Main Outlet Grou p and Controlled Outle t Group Ov ervi ew The Main Out let Group and the Cont rolled Out let Gro up can be con figured t o independe ntly tu rn of f, turn on, shut down, a nd reb oot c onnected equipmen t. (These f eatures a re [...]

  • Page 13

    Smart-UPS Rack-Mou nt2U 750/1000/150 0 VA 12 0/230 Vac, 3000 VA 100/12 0/208/230 Vac, 2200 VA 120 Vac 12 Cu stom ize th e M ain and C ont ro lled Ou tl et G ro ups Us e t he Contr ol menus to ch ange t he Main Outlet Gro up and the Controll ed Outle t Group settin gs. N etw or k Ma na ge ment C ard Set ti n gs These settings are av ailable only on [...]

  • Page 14

    13 Smart-UPS Rack- Mount2U 750/1000 /1500 VA 120/230 Vac, 3 000 VA 100/120/208/ 230 Vac, 2200 VA 120 Vac Emergen cy Power Of f EPO Over view The E mer gency Power Of f (E P O) optio n is a sa fety feat ure that will immediat ely disconne ct all connecte d equipm ent f rom util ity power . The UP S will imme diately shut down an d will not switc h t[...]

  • Page 15

    Smart-UPS Rack-Mou nt2U 750/1000/150 0 VA 12 0/230 Vac, 3000 VA 100/12 0/208/230 Vac, 2200 VA 120 Vac 14 T roublesh oot ing Pr oblem and Possible Cause Solution The UPS w ill not turn o n or there is n o ou tput The unit has not been turned o n. Pres s the ON key once to tu rn on the UPS . The UPS i s not c onnected to u til ity power . Be s ure th[...]

  • Page 16

    15 Smart-UPS Rack- Mount2U 750/1000 /1500 VA 120/230 Vac, 3 000 VA 100/120/208/ 230 Vac, 2200 VA 120 Vac The Fa ult LE D is illumi nate d The UPS displ ays a fau l t m ess age and emits a constant beep ing sound Int e rna l UPS f au lt. Do n ot at te mpt to us e the U PS . Turn t he UP S o ff and h av e it s erv iced im medi at ely . All L EDs are [...]

  • Page 17

    Smart-UPS Rack-Mou nt2U 750/1000/150 0 VA 12 0/230 Vac, 3000 VA 100/12 0/208/230 Vac, 2200 VA 120 Vac 16 Se rvice If th e u nit req uire s se rvi ce , d o no t retur n it to the de al er . Fol low t hese steps : 1. Review the T r ouble shooti ng se ction of t he manua l to elim inat e commo n pro blem s. 2. If the proble m pe rs i sts, conta ct APC[...]

  • Page 18

    17 Smart-UPS Rack- Mount2U 750/1000 /1500 VA 120/230 Vac, 3 000 VA 100/120/208/ 230 Vac, 2200 VA 120 Vac T wo Y e ar Limited Factory W arranty Schneid er Electri c IT Co rporation (SEIT ), warrants i ts p roducts to be free from defects in mater ia l s and workmanshi p for a pe riod of three (3) years e xcluding t he batte ries, which are warra nte[...]

  • Page 19

    [...]

  • Page 20

    [...]

  • Page 21

    05/20 13 EN 990- 3858 B APC by Schneide r Elect r i c World wide Cust omer Support Customer suppor t for this or any othe r APC by Schneider Ele ctric product is avail able at no charge in any of the followi ng ways: • V isit the APC by Schneider Elec tric W eb site to access documen ts in the APC by Schne ider Electric Knowledg e B ase and to su[...]