APC SMC10002U manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of APC SMC10002U, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of APC SMC10002U one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of APC SMC10002U. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of APC SMC10002U should contain:
- informations concerning technical data of APC SMC10002U
- name of the manufacturer and a year of construction of the APC SMC10002U item
- rules of operation, control and maintenance of the APC SMC10002U item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of APC SMC10002U alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of APC SMC10002U, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the APC service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of APC SMC10002U.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the APC SMC10002U item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Operation Manual Smart-UPS ™ C Uninterruptible Power Supply 1000/1500/2000/3000 V A Rack-Mount 2U 120/230 V ac s u 0 0 8 1 2 a[...]

  • Page 2

    [...]

  • Page 3

    1 Smart-UPS C 1000/1500/2000/300 0 VA 120/230 Vac Rack-Mount 2U Product Description The APC ™ by Schneider Electric Smart-UPS ™ C is a high performance un interruptible power supply (UPS). The UPS provides protection for electronic eq uipment from AC power blackouts, bro wnouts, sags, and surges, small AC power fluctuations and large disturbanc[...]

  • Page 4

    Smart-UPS C 1000/1500/2000/3000 VA 120/230 Vac Rack-Mount 2U 2 S pecifications For additional specifications, refer to the APC by Schneider Electric W eb site at www .apc.com. We i g h t specifications UPS + Battery Battery SMC1000-2U / SMC1000I-2U 20.48 kg (45.15 lb) APCRBC124 5.6 kg (12.32 lb) SMC1500-2U / SMC1500I-2U 27.8 kg (61.20 lb) APCRBC132[...]

  • Page 5

    3 Smart-UPS C 1000/1500/2000/300 0 VA 120/230 Vac Rack-Mount 2U Product Overview Front p anel features Rear p anel features  Display interface 1000V A 120/230 V ac  Bezel  Battery  Internal battery connector 3000 V A 230 V ac 1500 V A 120/230 V ac 2000 V A 230 V ac       UPS input Circuit breaker/Overload protection Ch[...]

  • Page 6

    Smart-UPS C 1000/1500/2000/3000 VA 120/230 Vac Rack-Mount 2U 4 Inst allation For UPS installation information, refer to the Installation Guid e for the Smart-UPS C 10 00/1500/200 0/ 3000 V A Rack-Mount 2U in cluded with the UPS. The Installation Guide is also av ailable on the Documentation CD included with the UPS and on the APC by Schneider Elect[...]

  • Page 7

    5 Smart-UPS C 1000/1500/2000/300 0 VA 120/230 Vac Rack-Mount 2U Operation Note: The UPS will char ge to 90% capacity in th e first three hours of normal operation. Do not expect full battery runtime capabili ty duri ng this initial charge period. 1. Connect equipment to the UPS. 2. Connect the UPS to a two pole , three wire, grounded source. Connec[...]

  • Page 8

    Smart-UPS C 1000/1500/2000/3000 VA 120/230 Vac Rack-Mount 2U 6 Sensitivi ty adjustment set tings The UPS detects and reacts to line voltage distortions by transferring to battery backup power to protect connected equipment. In situations where the connected eq uipment is too sensitive for the input voltage level it is necessary to adjust the transf[...]

  • Page 9

    7 Smart-UPS C 1000/1500/2000/300 0 VA 120/230 Vac Rack-Mount 2U LED st atus indicators LCD st atus indicators S tatus LED Audible Indicator On Audible Indicator T erminates Power On The UPS is supplying AC power to connected equipment. The On Line/On Battery LED illuminates green. None N/A On Battery The UPS is supplying battery power from the inte[...]

  • Page 10

    Smart-UPS C 1000/1500/2000/3000 VA 120/230 Vac Rack-Mount 2U 8 Display interface features 120 V ac 230 V ac Description On Line: The UPS is supplying conditio ned AC power to connected equipment . Green mode : The UPS is operating at the most efficient level, bypassing unused A VR components while acceptable AC voltage is present. The UPS will ente[...]

  • Page 11

    9 Smart-UPS C 1000/1500/2000/300 0 VA 120/230 Vac Rack-Mount 2U System Fault s For mor e information on System Faults, contac t customer support at the APC by Schneider Electric W eb site, www .apc.com/support. Feature Reference Guide Normal Mode Configuration Mode The Configuration Mode provides additional op tions for the UPS. Press and hold the [...]

  • Page 12

    Smart-UPS C 1000/1500/2000/3000 VA 120/230 Vac Rack-Mount 2U 10 Function Options Description Self-T est • 0: Default Setting • 1: Begin Self-T est When set to 1, pressing the DISPLA Y button will trigger the self test and exit the Confi guration Mode. 0 is the default setting and will not initiate a self test, by pressing the DISPLA Y button yo[...]

  • Page 13

    11 Smart-UPS C 1000/1500/20 00/3000 VA 120/230 Vac Rack-Mount 2U T roubleshooting Problem and Possible Cause Solution The UPS will not turn on or there is no output The UPS has not been turned on. Press the ON button once to turn on the UPS. The UPS is not connected to AC power . Be sure the power cable is securely c onnected to the UPS and to the [...]

  • Page 14

    Smart-UPS C 1000/1500/2000/3000 VA 120/230 Vac Rack-Mount 2U 12 Battery Replacement Always recycle used batte ries. For information on recycling a used ba ttery , refe r to the Battery Disposal Information sheet included with the re placement battery . Replace used batteries with APC by Schneider Elec tric approved batteries. T o order a replacemen[...]

  • Page 15

    13 Smart-UPS C 1000/1500/20 00/3000 VA 120/230 Vac Rack-Mount 2U T wo Y ear Limited Factory W arranty Schneider Electric IT Corporation (SEIT), warrants its products to be free from defects in materials and workmanship for a period of two (2) years excluding the batteries, which are warranted for one (1) year from the date of purchase. The SEIT ob [...]

  • Page 16

    Smart-UPS C 1000/1500/2000/3000 VA 120/230 Vac Rack-Mount 2U 14 T o obtain service under warranty you must obtain a Returned Material Au thorization (RMA) number from customer support. Customers with warranty claims issues may access the SEIT worldw ide customer support network through the SEIT W eb site: www .apc.com . Select your country from the[...]

  • Page 17

    [...]

  • Page 18

    12/2013 EN 990-4472C APC by Schneider Electric W orldwide Customer Support Customer support for this or any other APC by Schneider Electric product is available at no char ge in any of the following ways: • V isit the APC by Schneider Elec tric W eb site to access documents in the APC by Schneider Electric Knowledge Base and to submit customer su[...]