APC PM3 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of APC PM3, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of APC PM3 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of APC PM3. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of APC PM3 should contain:
- informations concerning technical data of APC PM3
- name of the manufacturer and a year of construction of the APC PM3 item
- rules of operation, control and maintenance of the APC PM3 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of APC PM3 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of APC PM3, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the APC service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of APC PM3.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the APC PM3 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    PM3 Seri es Non-Modu lar Su rge Pr otection Device (SPD ) User ’ s Manual Copyright © 2000 Am erican Power Conversion Corpor ation 132 Fa i rgrounds Road P .O. Box 278 W est K ingston, Rhod e Island 028 92 USA 990-0525 10/00[...]

  • Page 2

    6XU JH$UUHVW306HULHV INTRODUCTION .................... ...................... ............ ................. ...................... ............ ................ ................. 1 Installation .............. ....................... ............................ ....................... ........... ................ .................. ..... [...]

  • Page 3

    Ta b l e s T able 1 - V oltage Rating and Service T ype (by Model) ................... ............................ ...................... 4 T able 2 - Relay Con tact Pin Arrangement ................ ....................... ................. ...................... ......... 1 0 Figures Figur e 1 - SPD Mounting Requirements ............. ...........[...]

  • Page 4

    INTRODUCTION Thank you for choosing the APC Sur geArrest PM3 Series Surge Protection Device. The APC non-mo dular Sur ge Protection Devi ce (SPD) is a high qu ality , high energ y sur ge attenuation system that has been designed to protect sensitive equipment fro m d amaging transient v o ltage surges. Proper installati on is impera- tive to maximi[...]

  • Page 5

    LOCA TION CONSID ERA TIONS Environment 7KHXQLWLVGHVLJQHGWR RSHUDWHLQGRRUVLQDQDPELHQ W WHP SHUDWXUHUDQJHRI &  )WR  &  )ZLWK DUHODWLYHKXP LGLWRI   WR QRQFRQ G HQVLQJ7KHVWDQ[...]

  • Page 6

    Service Cl earance In addition to national and local code requirements, 32 inches of service clearance is needed at the front of th e SPD. Equipment Performance T o obtain the maximum system performan ce, the unit must be located as close to the circuit to be protected as possi- ble, mini mizing the interc onnectin g wire leng th. For ever y foot o[...]

  • Page 7

    Te r m i n a l s T erminals have been provid ed in side the APC non-m odular SPD units for li ne (phase), neut ral (if used), and equip- ment saf ety ground connect ions. T ermin al wire size range fo r all mode ls is #8 A WG - #1 A WG. Instal lation t orque is 65 inc h- pounds. Page 4 7 DE OH9 ROWDJ H5DWLQ JDQG6HU YLFH7 SH[...]

  • Page 8

    Parallel Connection When making a parallel type of connection (Figure 2), th e length of the wiring to the Surge Protection Devi ce (SPD) must b e kept as sh ort as possible to subst antially enhance the performance. Lo ng wire runs are to be avoided fo r the unit to perform as inten ded. T o reduce the impedan ce the wire dis plays t o sur ge curr[...]

  • Page 9

    7. Mount the SPD to the wall or other mounting surface using the flanges. The SPD should be installed as close as possible to the p a nel b eing protected. Page 6 Phase A Phase B Phase C Neutral Ground Not to exact sca le. Cover removed for clari ty . )LJXUH,QVWDOODWLRQ:LULQJ'LDJUDP V 0 RXQWLQJ )ODQJH SODFHV  /[...]

  • Page 10

    8. Dress the power cabl es so the ribbo n cables wi ll not be pinched , crush ed, or other wise damaged when th e cover is installed. If connecting Dry Contacts, it may be ef fective to in stall communication lines prior to p ower conductors. 9. Conn ect th e unit to the service pan el through the UL approved co nd uit with anti-short bu sh ings as[...]

  • Page 11

    OPERA TION and FEA TURES SPD’ s do not require alot of operator interven tio n after installation. NOTE: The PM Series has a green LED for each phase which exting uishes when the module is no longer pr oviding protecti on (fau lt cond it i on ). All of t he PM series of SP Ds contai n a diagno stic circu it which moni tors the suppressors st atus[...]

  • Page 12

    Audible Alarm and Control 7KH 30; 6HULHV GHYLFH L V HTXLSSHG  Z LWK DQ  DXGLOH DODUP Z KLFK Z LOO VRXQG LQ WK H HYHQW RI DQ DODUP FRQGLWLRQ   ,Q DGGLWLRQWKHUHG6HUYLFH/ ('ZLOOLO OX PLQ DWHLQGLFDWLQJWKHGHYLFH QHHGVVHUYLFH3UHVVWK H[...]

  • Page 13

    127(    3LQ SDLUV       DQG     DUH FRQQHFWHG YLD MXPSHU LQWHUQDOO   7KH FRPELQHG FXUUHQW RI HDFK SLQ SDLU PD QRWH[FHHG$PSHUH CORRECTIVE MA INTENANCE (Repair) 6XUJH$UUHVW 30; 6HULHV XQL WV DUH GH[...]

  • Page 14

    3DJH  67 $5 7 $ODUP (1' $XGLEOH9 LV XDO 5HG6HUYLFH /('/LW" $OO )URQW3DQHO *UHHQ/('V /LW " 1R $SSDUHQ W 3URE O HP 1R < HV 1R 3RVVLEOH 'LVSOD %RDUG )DLOXUH &DOO$3& 7 HFK QLFDO 6XSSRUW ,V 6HUYLFH 9 ROWDJH&RUU HFW RQDOO 3KDVHV" <H V &RUUHFW 3RZHU8WLOLW )HH[...]

  • Page 15

    Display Board Remov al and Replacement Instructions 7 RUHPRYHWKH'LVSOD ERDU GUHIHUWR)LJXUHDQGSUR FHHGDVIROORZV   'LVFRQQHFWSRZHUWRWKH63'  Carefully rem ove the front co ver by loosening t he fo ur (4) captive screws that secure the front cover to the chassis. In[...]

  • Page 16

    3DJH Disp lay Boa rd Chas si s C ov e r (Chassis not shown) )LJXUH'LVSOD%RDUG/RFDWRU'LDJUD P Not to exact scale . Ground W ire (to Ch assis) Display Bo ard Retaining Hardware (4 pl aces) Ribbon Cab les (to Chas sis) Ribbon Cab le Connecto r s[...]

  • Page 17

    LIMITED W ARRANTY APC warrants it’ s AC panel protection prod ucts against defects i n workmanship and materi als for 5 years from the date of original purchase. The panel protection device must be installed by a qualified and licensed el ectr ician in order t o qualif y for warrant y proctection . Liability is limited to the replacemen t of the [...]