Anaheim DPG1004-01 manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Anaheim DPG1004-01, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Anaheim DPG1004-01 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Anaheim DPG1004-01. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Anaheim DPG1004-01 should contain:
- informations concerning technical data of Anaheim DPG1004-01
- name of the manufacturer and a year of construction of the Anaheim DPG1004-01 item
- rules of operation, control and maintenance of the Anaheim DPG1004-01 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Anaheim DPG1004-01 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Anaheim DPG1004-01, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Anaheim service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Anaheim DPG1004-01.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Anaheim DPG1004-01 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    December 2004 DPG10002-01, DPG10003-01, DPG10004-01 Microstep Driver Pack User’s Guide #L010167 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471 website: www.anaheimautomation.com ANAHEIM AUTOMATION[...]

  • Page 2

    User’s Guide # L010167 DPG10002-01, DPG10003-01, DPG10004-01 Microstep Driver Pack Features • Integrated MBC10641, Power Supply, and Cooling Fan • 90-265 VAC Input • Output Current 10.0 Amps Peak • 200 to 12,800 steps/rev (1,2,5,8,10,16,32 and 64 selectable step operations) • Short Circuit Protection • Motor Miss-Wire Detection • No[...]

  • Page 3

    December 2004 # n i P n o i t p i r c s e D 1: ) + ( e d o n A t u p n I k c o l C p e t S e n o r o t o m e h t s e c n a v d a t u p n i d e t a l o s i s i h t n o e g d e g n i o g e v i t i s o p A . 1 h c t i w S f o s t u p n I t c e l e S p e t s o r c i M e h t n o t n e d n e p e d s i t n e m e r c n i e h t f o e z i s e h T . t n e m e[...]

  • Page 4

    User’s Guide # L010167 Absolute Maximum Ratings Input Voltage: 90-265 VAC Output Current: 10.0 AMPS PEAK Max Plate Temperature: 70° C Storage Temperature: 0° to +50° C Input Voltage (For isolated inputs): +5V to +24V at 2.5mA Optional: Non-Isolated +5VDC Output can power the MBC10641 Inputs (but isolation is eliminated). Electrical Specificati[...]

  • Page 5

    December 2004 Optically Isolated Inputs The following inputs to the MBC10641 are Optically Isolated. To enable an input, apply a DC voltage source of +5VDC to +24VDC across the inputs. The Anodes (+) are pins 1,3,and 5 and the Cathodes (-) are pins 2, 4, and 6. m e t I # n i P k c o l C2 & 1 n o i t c e r i D4 & 3 f f O / n O6 & 5 Motor[...]

  • Page 6

    User’s Guide # L010167 Microstep Selection (SW1 Settings) Switches 2, 3 and 4, of the DIP switch select the number of microsteps per step. Table 7 shows the standard resolution values along with the associated positions for the select switches. The standard wave- forms are sinusoidal. Setting the Output Current The output current on the MBC10641 [...]

  • Page 7

    December 2004 Step Motor Selection Guide Anaheim Automation offers motor cable, making hook-ups quick and easy! Contact the factory or visit our website for more motor and cable offerings. TABLE 5 - Table Selection for Anaheim Automation Motor Current Settings. Reducing Output Current Reducing the output current is accomplished by setting switch 1 [...]

  • Page 8

    User’s Guide # L010167 4 Lead Motors Multiply the specified series motor current by 1.4 to determine the current adjustment potentiometer value. Four Lead Motors are usually rated with their appropriate series current, as opposed to the Phase Current , which is the rating for 6 and 8 lead motors. 6 Lead Motors When configuring a 6 lead motor in a[...]

  • Page 9

    December 2004 8 Lead Motors Series Connection: When configuring the motor windings in series, use the per Phase (or unipolar) current rating to determine the current setting potentiometer value. Parallel Connection: When configuring the motor windings in parallel, multiply the per Phase (or unipo- lar) current rating by 2.0 to determine the current[...]

  • Page 10

    User’s Guide # L010167 Dimension Drawings DPG10002-01, DPG10003-01 and DPG10004-01 Micostep Driver Pack[...]

  • Page 11

    December 2004 COPYRIGHT Copyright 2001 by Anaheim Automation. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without the prior written p[...]

  • Page 12

    User’s Guide # L010167 ANAHEIM AUTOMATION Torque Speed Curves[...]