AMX AMX NetLinx Integrated Controller NXI manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of AMX AMX NetLinx Integrated Controller NXI, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of AMX AMX NetLinx Integrated Controller NXI one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of AMX AMX NetLinx Integrated Controller NXI. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of AMX AMX NetLinx Integrated Controller NXI should contain:
- informations concerning technical data of AMX AMX NetLinx Integrated Controller NXI
- name of the manufacturer and a year of construction of the AMX AMX NetLinx Integrated Controller NXI item
- rules of operation, control and maintenance of the AMX AMX NetLinx Integrated Controller NXI item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of AMX AMX NetLinx Integrated Controller NXI alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of AMX AMX NetLinx Integrated Controller NXI, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the AMX service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of AMX AMX NetLinx Integrated Controller NXI.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the AMX AMX NetLinx Integrated Controller NXI item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Operation/Reference Guide Controllers NXI NetLinx ® Integrated Controller Initial Release: / Last Revised: 1/8/ 2009[...]

  • Page 2

    AMX Limited Warranty and Disclaimer AMX Corporation warrants its product s to be free of defec ts in material and workmanship under normal use for three (3) years from the date of purchase from AM X Corporation, with the follow ing exceptions: • Electroluminescent and LCD Control Panels a re warranted for thr ee (3) ye ars, except for the display[...]

  • Page 3

    Table of Contents i NXI NetLinx Integrated Controller Table of Contents Product Information ...................... ..................................................................... 1 Front and Rear Panel Components .................... ......................... .................... .......... 1 Specifications .... ......................... ....[...]

  • Page 4

    ii NXI NetLinx Integrated Controller Table of Contents[...]

  • Page 5

    Product Information 1 NXI NetLinx Integrated Controller Product Information The NXI NetLinx Inte grated Controlle r represents the ne w generation of AMX multi-port cent ral controllers. The NXI can be programmed to control RS-232 /422/485, Relay , IR/Seria l, and Input/Output de vices using the NetLinx programming language and NetLinx Studio progr[...]

  • Page 6

    Product Information 2 NXI NetLinx Integrated Controller Specifications NXI Specifications Power requirements 1.09 A @ 12 VDC (NXI only/no card) Memory 64K of IR memory:· • 32K IR memory for IR ports 8-1 1 • 32K IR memory for IR ports 12-15 Por t s: RS-232/422/485 ports (#1-6) Six RS-232/422/485 control ports with XON/XOFF (transmit on/transmit[...]

  • Page 7

    Product Information 3 NXI NetLinx Integrated Controller NXI Specifications (Cont.) Rear P anel Components: RS-232/422/485 (ports 1-6) Six 10-pin (male) connec tors that support bi-directional RS-232/422/485 communication (XON/XOFF , CTS/RTS, 300-230,400 baud). • Channel range = 1-255 • Channels 1-254 provide feedback only .· • Channel 255 (C[...]

  • Page 8

    Product Information 4 NXI NetLinx Integrated Controller[...]

  • Page 9

    Connections and Wiring 5 NXI NetLinx Integrated Cont roller Connections and Wiring Installing the Master or Hub Card The NXC-ME260 NetLinx Master or any Hub Card can be installed in the NXI. The card mounts in a horizontal position, through the master card slot on the rear panel of the NXI enclosure (see FIG. 1 on page 1). T o install a Master or H[...]

  • Page 10

    Connections and Wiring 6 NXI NetLinx Integrated Controller IR/Serial Connections and Wiring Y ou can connect up to eight IR- or serial- controllable de vices to the IR/Serial connec tors (ports 8-15). These connectors accept an IR emitter (CC-NIRC) th at mounts on the de vice's IR window , or a mini- plug (CC-NSER) that connects to the de vice[...]

  • Page 11

    Programming 7 NXI NetLinx Integrated Cont roller Programming This section describes the Send_C ommands, Send_Strings, and Channel commands you can use to program the NXI. The e xamples in this se cti on require a declaration in the DEFI NE_DEVICE section of y our program to work correct ly . Refer to the NetLinx Pro gramming Language instruction ma[...]

  • Page 12

    Programming 8 NXI NetLinx Integrated Controller Program Port Commands The Program port commands l isted in th e follo wing table can be sent directly to the Master Card using a terminal program (i.e. T elnet). Be sure that your PC's COM port a nd terminal program's communication settings match those in the tabl e below: In your terminal p[...]

  • Page 13

    Programming 9 NXI NetLinx Integrated Cont roller Program Port Comma nds (Cont.) PROGRAM INFO Displays the NetLinx program's name residing in the Master Card. PULSE Pulses a channel on a device on and of f. The device can be on any sys- tem the master you are connected to can reach. Y ou can specify the device number , port, and system, or the [...]

  • Page 14

    Programming 10 NXI NetLinx Integrated Controller ESC Pass Codes There are 'escape' codes in the pass mode. These code s can switch the display mode or exit pass mode. The follow ing 'escape' codes are defined. Program Port Comma nds (Cont.) SHOW NOTIFY Displays a list of devices that other systems have requested inp ut from and [...]

  • Page 15

    Programming 11 NXI NetLinx Integrated Cont roller Notes on Specific Telnet/Terminal Clients T elnet and terminal clients will hav e different behaviors in some situations . This section sta tes some of the known anomalies. Windows TM client pro grams Anomalies occur when using a W indo ws client if you are not typing standard ASCII characters (i.e [...]

  • Page 16

    Programming 12 NXI NetLinx Integrated Controller RS-232/422/485 Send_Commands RS-232/422/485 Send_Commands B9MOFF Sets the port's communica- tion parameters for stop and data bits according to the software settings on the RS- 232 port (default). This command works in conjunction with the B9MON co mmand. Syntax: SEND_COMMAND <DEV>,'B[...]

  • Page 17

    Programming 13 NXI NetLinx Integrated Cont roller RS-232/422/485 Send_C ommands (Cont.) SET BAUD Sets the RS-232/422/485 port's communication param- eters. Syntax: SEND_COMMAND <DEV>,'SET BAUD (Baud),(Parity),(Data),(Stop) (485 DISABLE/ENABLE)' V ariables: Baud = 150, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400 ( factory set[...]

  • Page 18

    Programming 14 NXI NetLinx Integrated Controller RS-232/422/485 Send_C ommands (Cont.) RXON S tarts transmitting received characters to the Master Card. This command is sent automatical ly when issuing a CREA TE_BUFFER Send_Command. Syntax: SEND_COMMAND <DEV>,'RXON' Example: SEND_COMMAND RS232_1,'RXON' Sets the RS232_1 dev[...]

  • Page 19

    Programming 15 NXI NetLinx Integrated Cont roller RS-232/422/485 Send_String Escape Sequences RS-232/422/485 Send_Stri ng Escape Sequences 27,17, Sends device-s pecific break characters for a specified duration. Syntax: SEND_STRING <DEV>,"27,17,<Time>" V ariable: T ime = 1-255 in 100 microsecond increments Example: SEND_STRING[...]

  • Page 20

    Programming 16 NXI NetLinx Integrated Controller IR / Serial Ports (8 - 15) Channels IR/Serial Send_Commands The following IR and IR/Serial Send_Commands ge nerate control signals for external equipment. IR / Serial Ports Channels 00001 - 00229 IR commands. 00229 - 00253 May be used for system call feedback. 00254 Power Fail. (Used with the 'P[...]

  • Page 21

    Programming 17 NXI NetLinx Integrated Cont roller IR/Serial Send_Commands (Cont.) CTOF Sets the duration of off time (no signal) between IR pulses for channel and IR function transmissions. Off time set- tings are stored in non-vola- tile memory . The factory default for channel off time is 5 (.5 second). This command is associated with the SP (sin[...]

  • Page 22

    Programming 18 NXI NetLinx Integrated Controller IR/Serial Send_Commands (Cont.) PON T urns on a device, based on input Link. If at any time the IR sensor reads that the device is off (such as if one turned it off manually at the front panel), the card automatically attempts to turn the device back on. If three attempts fail, card will continue exe[...]

  • Page 23

    Programming 19 NXI NetLinx Integrated Cont roller IR/Serial Send_Commands (Cont.) SP Generates a single IR pulse. Y ou can use the CTON to set pulse lengths and CTOF for time off between pulses. Syntax: SEND_COMMAND <DEV>," 'SP',<IR OUT>" V ariable: IR OUT = 1-252 and 256-65,000 Example: SEND_COMMAND IR_1, " &ap[...]

  • Page 24

    Programming 20 NXI NetLinx Integrated Controller IR/Serial Send_Commands (Cont.) XCHM Changes the IR output pat- tern for the XCH command. Syntax: SEND_COMMAND <DEV>,'XCH-<Mode>' V ariable: Mode = 0-4 Example: SEND_COMMAND IR_1,'XCH 3' Sets the IR_1 device's extended channel command to mode 3. Mode 0 Example (de[...]

  • Page 25

    Programming 21 NXI NetLinx Integrated Cont roller Input/Output Send_Commands The following Send_Com mands prog ram the I/O ports on the NXI. IR/Serial Send_Commands (Cont.) ZAP HIGH Deletes all IR data stored in the NXI ports 12-15. Syntax: SEND_COMMAND <DEV>, 'ZAP HIGH' Example: SEND_COMMAND IR_4, 'ZAP HIGH' Deletes IR co[...]

  • Page 26

    Programming 22 NXI NetLinx Integrated Controller[...]

  • Page 27

    Programming 23 Enter the Document Name Here[...]

  • Page 28

    1/09 © 2009 AMX. All rights reserved. AMX and the AM X logo are register ed trademarks of AMX. AMX reserves the ri ght to alter specifica tions without notice at any time. It’s Your World - Take Con trol™ 3000 RESEARCH DRIVE, RICHARDSON, TX 75082 USA • 800.222.0193 • 469.624.8000 • 469-624-7153 fax • 800.932.6993 technical support • [...]