American Water Heater 318935-003 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of American Water Heater 318935-003, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of American Water Heater 318935-003 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of American Water Heater 318935-003. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of American Water Heater 318935-003 should contain:
- informations concerning technical data of American Water Heater 318935-003
- name of the manufacturer and a year of construction of the American Water Heater 318935-003 item
- rules of operation, control and maintenance of the American Water Heater 318935-003 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of American Water Heater 318935-003 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of American Water Heater 318935-003, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the American Water Heater service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of American Water Heater 318935-003.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the American Water Heater 318935-003 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1 Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHA T TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s phone. Follow the gas sup[...]

  • Page 2

    2 T able Of Contents W ater Heater Safety .............................................................................. 1-2 Installing Y our Gas W ater Heater ........................................................ 3-16 Unpacking the W ater Heater ........................................................... 3 Location Requirements ................[...]

  • Page 3

    3 INST ALLING YOUR GAS W A TER HEA TER Important Information About This W ater Heater This gas water heater was manufactured to voluntary safety standards to reduce the likelihood of a flammable vapor ignition incident. New technology used in meeting these standards makes this product more sensitive to installation errors or improper installation e[...]

  • Page 4

    4 Location Requirements The Flame Guard™ Safety System is designed to reduce the risk of flammable vapor-related fires. The patented system protects your family by trapping the burning vapors within the water heater combustion chamber through the special flame-trap. The burning vapors literally “burn themselves out” without escaping back into[...]

  • Page 5

    5 IMPORT ANT : The water heater should be located in an area where leakage of the tank or connections will not result in damage to the area adjacent to the water heater or to lower floors of the structure. Due to the normal corrosive action of the water , the tank will eventually leak after an extended period of time. Also any external plumbing lea[...]

  • Page 6

    6 Gas Supply Gas Requirements IMPORT ANT : Read the data plate to be sure the water heater is made for the type of gas you will be using in your home. This information will be found on the data plate located near the gas control valve/thermostat. If the information does not agree with the type of gas available, do not install or light. Call your de[...]

  • Page 7

    7 Combustion Air Supply and V entilation IMPORT ANT : Air for combustion and ventilation must not come from a corrosive atmosphere. Any failure due to corrosive elements in the atmosphere is excluded from warranty coverage. The following types of installation (not limited to the following) will require outdoor air for combustion due to chemical exp[...]

  • Page 8

    8 Unconfined Space A water heater in an unconfined space uses indoor air for combustion and requires at least 50 cubic feet for each 1,000 BTU/HR of the total input for all gas appliances. The table below shows a few examples of the minimum square footage (area) required for various BTU/HR inputs. IMPORT ANT : • The area must be open and be able [...]

  • Page 9

    9 All Air from Outdoors Outdoor fresh air can be provided to a confined area either directly or by the use of vertical and horizontal ducts. The fresh air can be taken from the outdoors or from crawl or attic spaces that freely communicate with the outdoors. Attic or crawl spaces cannot be closed and must be properly ventilated to the outside. Duct[...]

  • Page 10

    10 V ent Pipe System This water heater uses a non-direct, single-pipe vent system to remove exhaust gases created by the burning of fossil fuels. Air for combustion is taken from the immediate water heater location or is ducted in from the outside (see “Combustion Air Supply and V entilation” section). This water heater must be properly vented [...]

  • Page 11

    11 Chimney Connection IMPORT ANT : Before connecting a vent to a chimney , make sure the chimney passageway is clear and free of obstructions. The chimney must be cleaned if previously used for venting solid fuel appliances or fireplaces. Also consult local and state codes for proper chimney sizing and application or , in the absence of local and s[...]

  • Page 12

    12 W ater System Piping Piping Installation Piping, fittings, and valves should be installed according to the installation drawing (Figure 13). If the indoor installation area is subject to freezing temperatures, the water piping must be protected by insulation. The water supply pressure should not exceed 80 psi. If this occurs, a pressure reducing[...]

  • Page 13

    13 Please note the following: • The system should be installed only with piping that is suitable for potable (drinkable) water such as copper , CPVC, or polybutylene. This water heater must not be installed using iron piping or PVC water piping. • Use only pumps, valves, or fittings that are compatible with potable water . • Use only full flo[...]

  • Page 14

    14 T emperature and Pressure Relief V alve For protection against excessive pressures and temperatures, a temperature and pressure relief valve must be installed in the opening marked “T & P RELIEF V AL VE” (see Figure 15A). This valve must be design certified by a nationally recognized testing laboratory that maintains periodic inspection [...]

  • Page 15

    15 Special Applications Combination Space Heating/Potable W ater System Some water heater models are equipped with inlet/outlet tappings suitable for combination water (potable) heating and space heating and not suitable for space heating applications only . If this water heater is to be used to supply both space heating and domestic potable (drink[...]

  • Page 16

    16 W ater Heater Location W ater heater location is important and can affect system performance. Please check the following: □ Installation area free of corrosive elements and flammable materials. □ Centrally located with the water piping system. Located as close to the gas piping and vent pipe system as possible. □ Located indoors and in a v[...]

  • Page 17

    17 OPERA TING YOUR W A TER HEA TER Lighting Instructions Read and understand these directions thoroughly before attempting to light or re-light the pilot. Make sure the viewport is not missing or damaged. (See Figure 23) Make sure the tank is completely filled with water before lighting the pilot. Check the data plate near the gas control valve/ th[...]

  • Page 18

    18 FOR YOUR SA FETY REA D B EFORE L IGHTING A. T his a pplia nce ha s a pilot which is lighte d by a pie z oe le ctric ignite r . W he n lighting the pilot, follow the se instructions e xa ctly . B. BE F O R E LI G H T I N G sme ll a ll a round the a pplia nce a re a for ga s. Be sure to sme ll ne xt to the floor be ca use some ga s is he a vie r t[...]

  • Page 19

    19 Burner Flames Inspect the burner flames through the viewport. Flames should be very small with a blue haze and small amounts of yellow or orange at the edges. After several minutes of operation, the burner screen may glow red. If large flames are observed at any time, shut-off unit and call a qualified person. W ater T emperature Stacking Stacki[...]

  • Page 20

    20 W ater T emperature Regulation The thermostat is adjusted to the pilot position when it is shipped from the factory . Water temperature can be regulated by moving the temperature dial to the preferred setting. The preferred starting point is 120°F at the “HOT” setting. Align the knob with the desired water temperature as shown in Figure 19A[...]

  • Page 21

    21 Operating the T emperature Control System Figure 19B: Status Codes VAC List of status codes are shown at top of gas control valve/thermostat. W ater T emperature Adjustment The water temperature setting can be adjusted from 55°F to 155°F . T urn the Gas Control/T emperature Knob to the desired setting/temperature. NOTE: The temperatures indica[...]

  • Page 22

    22 NOTE : This rod may reduc e but not eliminate w ater odo r problems. The water supply system ma y require spec ial f iltration equipment from a water co nditioning company to succ essfully eliminate all water odor problems. Ar tif icially sof tened water is e xceedingly c orrosive because the proc ess substitutes sodium i ons for magnesium and c[...]

  • Page 23

    23 MAINTENANCE OF YOUR W A TER HEA TER Draining and Flushing It is recommended that the tank be drained and flushed every 6 months to remove sediment which may build up during operation. The water heater should be drained if being shut down during freezing temperatures. T o drain the tank, perform the following steps: 1. T urn off the gas to the wa[...]

  • Page 24

    24 Replacement Parts IMPORT ANT : The following maintenance procedures are for the Flame Guard™ Safety System components and should be performed by a qualified person. Replacement parts may be ordered through your plumber or the local distributor . Parts will be shipped at prevailing prices and billed accordingly . When ordering replacement parts[...]

  • Page 25

    25 Replacing the Pilot/Thermopile Assembly 1. Remove the burner assembly . See Removing the Burner Door Assembly Section. 2. Lift the retainer clip straight up from the back of the manifold component block (using a flat-blade screwdriver), then remove the manifold component block from the burner door (Figure 25). IMPORT ANT : Be careful not to bend[...]

  • Page 26

    26 Pilot Thermopile Pilot/Thermopile Assembly Pilot Tube (Ferrule Nut Not Shown) Igniter Connector Thermopile Connectors Figure 28 Pilot/Thermopile Assembly (50K Models) 6. Push the new pilot/thermopile assembly connectors through the opening in the burner door (See Figure 27). Do not to scrape or nick the wires during installation. IMPORT ANT : DO[...]

  • Page 27

    27 if the door gasket does not create a seal between the burner door and the combustion chamber . 6. Reconnect the manifold tubing (3/4” wrench), pilot tubing (7/16” wrench), temperature sensor wires, and thermopile wires to the gas control valve/thermostat. (See Figure 22 for the correct position of the thermopile wires.) Do not cross-thread o[...]

  • Page 28

    28 Flame Guard™ Safety System Operational Checklist TROUBLESHOOTING CHART 4. Manifold component block properly installed. 5. No leaks at pilot and manifold connection. 6. Burner door screws securely tightened. 1. Burner door gasket properly sealed. 2. V iewport not damaged or cracked. 3. Flame-trap free of debris and undamaged. PROBLEM POSSIBLE C[...]

  • Page 29

    29 PROBLEM POSSIBLE CAUSE(S) CORRECTIVE ACTION PILOT WILL NOT LIGHT OR REMAIN LIT (continued) 9. ECO switch open 10. Pilot line or orifice clogged 1 1. Non-functioning thermopile 12. Air for combustion obstructed 13. Flammable vapors incident, Flame Guard™ function utilized 9. Replace gas control valve/thermostat 10. Clean, locate source and corr[...]

  • Page 30

    30 ST A TUS LIGHT CODE TROUBLESHOOTING CHART LED ST A TUS PROBLEM CORRECTIVE ACTION 0 FLASHES (LED NOT LIT) Pilot light is not lit. Not enough power (millivolts) to keep it lit. Follow the lighting instructions on the front of the water heater and record any diagnostic codes. See Diagnostic Status Light Code section. 1 FLASH (EVERY 3 SECONDS) Norma[...]

  • Page 31

    31 PILOT LIGHT TROUBLESHOOTING CHART Have you bled all the air from the pilot tube and gas supply line? NO While repeatedly depressing the igniter button, push in and hold the gas control/ temperature knob until the pilot is lit and maintains a stable flame, (status light will blink) then release the gas control/ temperature knob. Section A: Pilot [...]

  • Page 32

    32 REP AIR P ARTS ILLUSTRA TION 1A 2 3 8 5A 10 11 9 7 6A 6B 5B 4 1B LEGEND Special anode rod (see page 21) T emperature and Pressure Relief V alve is required, but may not be factory installed Unique: Flame Guard™ Safety System parts When ordering repair parts always give the following information: 1. Model, serial, and product number 2. T ype of[...]

  • Page 33

    33 Listed Parts Kits and Illustrations Item 12A: Pilot assembly kit, which contains the pilot, electrode, and thermopile (Natural Gas) Item 12B: Pilot assembly kit (50K Models), which contains the pilot, electrode, and thermopile (Natural Gas) Item 13A: Burner Door assembly , which contains the burner , gasket, door , pilot tube, manifold component[...]

  • Page 34

    34 NOTES[...]