American Power Conversion 450 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of American Power Conversion 450, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of American Power Conversion 450 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of American Power Conversion 450. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of American Power Conversion 450 should contain:
- informations concerning technical data of American Power Conversion 450
- name of the manufacturer and a year of construction of the American Power Conversion 450 item
- rules of operation, control and maintenance of the American Power Conversion 450 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of American Power Conversion 450 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of American Power Conversion 450, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the American Power Conversion service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of American Power Conversion 450.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the American Power Conversion 450 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Notice: In case of a problem with this product, do not return to the place of purchase. Go to the support page at www.apcc.com for Technical Support or call 1-800-800-4272 for prompt customer service. 990-5022A, Revision 2 6/99 APC PowerStack 450 100V Uninterruptible Power Supply User’s Manual[...]

  • Page 2

    990-5022A, Revision 2 6/99 PowerStack 450 Quick Reference Guide English About Your New PowerStack UPS This Uninterruptible Power Supply (UPS) is designed to prevent blackouts, brownouts, sags and surges from reaching your computer and other valuable electronic equipment. This UPS also filters out small utility line fluctuations and isolates your eq[...]

  • Page 3

    990-5022A, Revision 2 6/99 Table of Contents Safety ........................................................................................................................................................................................................... 1 Initial Inspection .........................................................................[...]

  • Page 4

    [...]

  • Page 5

    990-5022A, Revision 2 6/99 1 Safety This section contains important instructions that should be followed during installation and maintenance of the PowerStack 450 and batteries. It is intended for customers who setup, install, relocate, or maintain APC equipment. Electrical Safety • Do not work alone under hazardous conditions. • High short cir[...]

  • Page 6

    990-5022A, Revision 2 6/99 2 • Do not use a ramp inclined at more than 10 ° . • This equipment is intended for installation in a temperature-controlled (0 ° - 40 ° C) indoor area, free of conductive contaminants.[...]

  • Page 7

    990-5022A, Revision 2 6/99 3 Initial Inspection Inspect the APC PowerStack 450 UPS upon receipt. Notify the carrier and dealer if there is damage. The packaging is recyclable; save it for reuse or dispose of it properly. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the warr[...]

  • Page 8

    990-5022A, Revision 2 6/99 4[...]

  • Page 9

    990-5022A, Revision 2 6/99 5 Setup Note: The UPS will not power up initially unless the AC voltage is in the normal operating range. Rear View Plug the power cord into the power supply. Connect equipment to the output receptacles. • Do not power laser printers through the UPS. • Use your equipment’s power cords to connect to the UPS. • Turn[...]

  • Page 10

    990-5022A, Revision 2 6/99 6 LEDs and Audible Alarms The on-line LED illuminates when the UPS is supplying utility power to the loads. On Battery During on-battery operation, the on-battery LED illuminates and the UPS sounds an audible alarm consisting of four beeps every 30 seconds. The alarm stops when the UPS returns to on-line operation. Overlo[...]

  • Page 11

    990-5022A, Revision 2 6/99 7 Operating Modes Shutdown Mode In shutdown mode the UPS stops supplying power to the load, waiting for the return of utility power. If there is no utility power present, external devices (e.g., servers) connected to the computer interface can command the UPS to shut down. This is normally done to preserve battery capacit[...]

  • Page 12

    990-5022A, Revision 2 6/99 8 Replacing the Battery Pack This UPS has an easy to replace hot-swappable battery pack. Note: Please read the cautions in the APC Safety Guide . Replacement Batteries See your dealer or call the number in this manual for information on replacement battery pack kits, order RBC18 . Battery Pack Replacement Procedure Batter[...]

  • Page 13

    990-5022A, Revision 2 6/99 9 Specifications Acceptable input voltage 0 - 150 VAC Input voltage (on-line operation) Nominal Range Maximum Range User adjustable through PowerChute® plus . 74-119 VAC 69-126 VAC Output voltage) Nominal Range Maximum Range User adjustable through PowerChute® plus . 92-108 VAC 86-114 VAC Input Over Current Protection R[...]

  • Page 14

    990-5022A, Revision 2 6/99 10 9. Include a letter with your name, RMA#, address, copy of the sales receipt, description of the trouble, your daytime phone number, and a check (if necessary). 10. Mark the RMA# on the outside of the package. 11. Return the UPS by insured, prepaid carrier to the address given to you by Customer Service. APC Japan Cont[...]