American Power Conversion 1500 VA, manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of American Power Conversion 1500 VA,, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of American Power Conversion 1500 VA, one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of American Power Conversion 1500 VA,. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of American Power Conversion 1500 VA, should contain:
- informations concerning technical data of American Power Conversion 1500 VA,
- name of the manufacturer and a year of construction of the American Power Conversion 1500 VA, item
- rules of operation, control and maintenance of the American Power Conversion 1500 VA, item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of American Power Conversion 1500 VA, alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of American Power Conversion 1500 VA,, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the American Power Conversion service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of American Power Conversion 1500 VA,.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the American Power Conversion 1500 VA, item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    990-1851D 03/2007 User Manual English APC Smart-UPS ® SC 1000/1500 VA 110/120/230 Vac Tower/Rack-Mount 2U Uninterruptible Power Supply[...]

  • Page 2

    [...]

  • Page 3

    1 Introduction The APC Uninterruptible Power Supply (UPS) is de signed to prev ent blackouts, brownou ts, sags, and surges from reaching y our eq uipment. The uninterruptible powe r supply (UPS) filters small util- ity line fluct uations and i solates yo ur equipm ent from l arge disturbances by inter nally disconnect ing from the utility line. The[...]

  • Page 4

    2 Tower Configuration Note: Illustrations in this document may appear different than the actual hardware. " # $ % Mount the UPS in a Two-Post Rack " # Remove b attery bracket screws, battery bracket, an d batte ry.[...]

  • Page 5

    3 $ % Note: For information on the four-po st rack- mounting ki t, see www.apc.com . & Reinstall battery, battery bracket, a nd screws. '[...]

  • Page 6

    4 2: S T ART UP Connect Equipment to the UPS Rear Panels 110/120 V: 230 V: • Note: A laser printer draws significantly more power than other types of equipment and may overload t he UPS. Connect the UPS to the Network (if Applicable) Network Connectors Serial Port Modem/Telephone/Fa x Ports Network Surge Suppression Ports Use only interface kits [...]

  • Page 7

    5 Start the UPS 1. Plug the UPS into a two-pole , three-wi re, grounded rece ptacl e only. Avoi d using e xtension cords. 110/120 V mo dels : The power cord is attached to the UPS. The input p lug is a NEMA 5- 15P. 230 V models: The power cord is supplied in the UPS literature kit. 2. 110/120 V models : Check the site wiring fault LED located on th[...]

  • Page 8

    6 3: O PERA TION Front Display Panel 110/120 V 230 V I NDICATOR D ESCRIPTION On Line The UPS is supplying utility power to the conn ected equipment. On Battery The UPS is supplying battery power to the connected equipment. Overload The connected loads are drawing more th an the UPS power rating. Replace Batter y/ Battery Disconnected The battery is[...]

  • Page 9

    7 4: U SER C ONFIGURABLE I TEMS N OTE : S ETTINGS ARE A DJUSTED THROUGH P OW ER C HUTE SOFTWARE F UNCTION F ACT OR Y D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Self-Test Every 14 days (336 hours) Every 7 d ays (168 hours), Every 14 days (336 hours), On Startup Only, No Self-Test Set the interval at which the UPS will execute a self-t est. UPS[...]

  • Page 10

    8 N OTE : S ETTINGS ARE A DJUSTED THROUGH P OW ER C HUTE SOFTWARE F UNCTION F ACT OR Y D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Low Battery Warning 2 minutes PowerChute Business Edition software provides automatic, unat- tended shutdown when approxi- mately 2 minutes of battery oper- ated runtime re- mains. 2, 5, 7, 10 minutes (Times are ap[...]

  • Page 11

    9 5: S TORAGE AND M AIN TENANCE Storage Store the UPS covered in a cool, dr y loca tion, with th e battery fu lly charged . At -15 to +30 ° C (+5 to +86 ° F), charge the UPS batt ery ever y six months. At +30 to +45 ° C (+86 to +113 ° F), charge the UPS battery every three months. Battery Replacement The UPS battery life differs based on us age[...]

  • Page 12

    10 6: T ROUBLESHOOTING , S HIPPING , AND S ERVICE Use the chart below to solve minor UPS installation and operation problems. Refer to www.apc.co m with complex UPS problems. P ROBLEM AND / OR P OSSIBLE C AUS E S OLUTION UPS WILL NOT TURN ON UPS not connected to utility power supply. Check that the po wer cord from the UPS to the u tility power sup[...]

  • Page 13

    11 P ROBLEM AND / OR P OSSIBLE C AUS E S OLUTION THE OVERLOAD LED IS ILLU MINATED AND THE UPS EMITS A SUSTAINED ALAR M TONE The UPS is over loaded. The connected equipment is dr aw- ing more VA than the UPS can sustain. The connected equipmen t exceeds the specif ie d “maximum load.” The alarm remains on unt il the overlo ad is removed. Disconn[...]

  • Page 14

    12 Shipping and Service Prepare the UPS for shipping: Shutdown an d disconnect any equipm ent attached to the UPS. Shut down the UPS, and disconnect the UPS from the utility power outlet. Discon nect the battery. If the UPS requires service do not return it to the dealer. Follow these step s: 1. Review the problems discussed in Troubleshooting to e[...]

  • Page 15

    13 7: R EGULA TOR Y AND W ARRANTY I NFORMA TION 110/120 V models This equipment has been tested and fou nd to comply with the limits for a Class A digital device, pur- suant to part 15 of the FCC Rules. These li mits ar e designed to pr ovide reaso nable prote ction against harmful interference when the equ ipment is operat ed in a commercial envir[...]

  • Page 16

    14 Limited Warranty American Power Conversion (APC) warrants its p roducts to be free from defects in materials and workmanship for a period of two years from the date of purchas e. It s obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. To obtain service under warranty you must[...]