Alto 52C3KSA -1 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Alto 52C3KSA -1, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Alto 52C3KSA -1 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Alto 52C3KSA -1. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Alto 52C3KSA -1 should contain:
- informations concerning technical data of Alto 52C3KSA -1
- name of the manufacturer and a year of construction of the Alto 52C3KSA -1 item
- rules of operation, control and maintenance of the Alto 52C3KSA -1 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Alto 52C3KSA -1 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Alto 52C3KSA -1, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Alto service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Alto 52C3KSA -1.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Alto 52C3KSA -1 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1 52C3KSA -1 52C3KSA -2 Operator’ s manual US A IMPORTANT: For your own safety and that of others, please make certain that everyone who uses the 52C3KSA-1/-2 high pressure washer reads and understands these instructions thoroughly prior to operation.[...]

  • Page 2

    2                        C3KSA-1 C3KSA-2      [...]

  • Page 3

    3 IMPORTANT: Read this instruction manual before you start up your high pressure washer for the first time. This machine is a high pressure washer produc- ing a water jet under high pressure which is why severe injuries can occur if the safety precautions are not observed. Therefore a complete understanding of the contents of this instruction manua[...]

  • Page 4

    4 1. 1 Model tag This ALTO high pressure washing system has the serial designation C3KSA. The system is available with one and two pumps respectively. The designation appears from the text on the cabinet, ALTO 52C3KSA- 2 as an example, and the model tag (pos. 9) on the right side of the machine. The tag provides the following details: 1.0 Survey of[...]

  • Page 5

    5 2.0 Instructions for use Safety precautions and warnings US Before starting your high pressure washer for the first time, we advise you to read through the following sections: 2.0 Instructions for use and 3.0 Operating instructions and to follow all instructions to ensure the protection of user, surroundings and machine. - WARNING - Risk of Injec[...]

  • Page 6

    6 Safety precautions and warnings US z For safety reasons only use original ALTO accessories and spare parts. Otherwise the machine could be damaged. z In freezing conditions, never start the machine until it, and the hoses and accessories have thawed. z The machine should not be covered during operation. z The most efficient cleaning is obtained i[...]

  • Page 7

    7 Safety precautions and warnings US z When using detergents, the instructions should always be strictly observed. z Always unplug the machine before cleaning or maintenance of the machine. z Don’t use the machine if the power cord or important parts of the equipment are damaged - i.e. safety devices, high pressure hoses, spray handles, cabinet. [...]

  • Page 8

    8 3.0 Installation US 3. 1 Water connection Flexible hose connection Max. water pressure 218 psi Max. 160°F Inlet water shutoff cock required Clean water inlet screen (1) at monthly intervals The water connection is made through a flexible hose connected to the quick coupling on the water inlet (1) of the machine. The connection can be made to a c[...]

  • Page 9

    9 O Start 1 Installation US 3.4 Venting KSA-1 Turn to position „Start“ Activate spray handle/open outlet point In the case of newly installed systems, or if the pipeline and the pump have been drained in any other way, the system should be vented by starting the pump and then let the water run freely at each outlet point of the pipeline in turn[...]

  • Page 10

    10 4.0 Operating instructions US 4.1 Connections 1. High pressure hose - directly on the machine Max. length of extension hose: 160 ft. Only use ALTO high pressure hose Danger of scalding! Never dismount high pressure hoses at water temperatures above 120°F The high pressure hose with imprinted max. working pressure and temperature should be attac[...]

  • Page 11

    11 Operating instructions US 4. Detergents If you want to apply detergents or disinfectants these can be metered through an accessory injector. Below you will find various types of outlet points with injectors. Outlet point with detachable injector To be attached to the quick coupling of the high pressure cock. To be used for dosing of low-foaming [...]

  • Page 12

    12 C3KSA-2 2 1+2 O 1    Operating instructions US 4. 2 Starting Check that the oil level in the oil reservoir(s) (2) is between the MIN. and MAX. markings. The inlet water shut-off cock should be open. NOTE: The system automatically stops after approx. 4 seconds if there is no water consumption. In the event of a power failure or activatio[...]

  • Page 13

    13 Operating instructions US 4. 4 Double spray lance, regulation of pressure and water volume - KSA-1 Turn spray lance pressure reducing valve (1): Clockwise (B): high pressure Counter clockwise (A): low pressure/ detergent application The spray lance employs a high pressure nozzle and a low pressure nozzle. On KSA-1 pump systems the water volume i[...]

  • Page 14

    14 Operating instructions US 4. 6 End of operation Turn to position 0 Never detach the high pressue hose while the machine is in operation = Position 1, 2 or 1+2. Danger of scalding! Never detach high pressure hoses at a water temperature above 120°F To stop the machine turn the red start/stop knob (1) to position 0. Close the shut-off cock of the[...]

  • Page 15

    15 5.0 Applications and working methods US 5. 1 Fields of application The most important fields of application for this product are: Agriculture Cleaning machinery, agricultural implements, stalls, equipment, and buildings Transport Cleaning trucks, buses, cars etc. Building and construction Cleaning vehicles, equipment, buildings etc. Light indust[...]

  • Page 16

    16 Applications and working methods US General rules for addition of detergents ALTO cleaning equipment can be used for all detergents and disinfectants, which are suitable for high pressure cleaning according to the supplier. (The pH-value should be between 4 and 14). Acid and lye should not be applied in a concentrated form. Carefully observe the[...]

  • Page 17

    17 6.0 Maintenance US A minimum of maintenance ensures prolonged and problem-free operation. It’s a good idea to make a habit of the following: Prior to attaching the water hose and the high pressure hose, the quick couplings should be rinsed to remove dirt. Prior to attaching the spray lance or other accessories to the spray handle, the machine [...]

  • Page 18

    18 7.0 Troubleshooting and correction US You have chosen the best quality and therefore deserve the best service. To avoid unnecessary disap- pointments, you should check the following before contacting the nearest ALTO service organisation: Fault Cause Correction Machine will not start A fuse has blown Change the fuse Power/plug not connected Conn[...]

  • Page 19

    19[...]

  • Page 20

    [...]

  • Page 21

    [...]

  • Page 22

    22[...]

  • Page 23

    23[...]

  • Page 24

    24 630 79 67 (00.10) Printed in Denmark Copyright © 2000-2001 ALTO Danmark A/S ALTO Danmark A/S Industrikvarteret DK-9560 Hadsund Tel.: +45 7218 2100 www.alto-online.com[...]