Alto-Shaam 500-3D manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Alto-Shaam 500-3D, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Alto-Shaam 500-3D one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Alto-Shaam 500-3D. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Alto-Shaam 500-3D should contain:
- informations concerning technical data of Alto-Shaam 500-3D
- name of the manufacturer and a year of construction of the Alto-Shaam 500-3D item
- rules of operation, control and maintenance of the Alto-Shaam 500-3D item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Alto-Shaam 500-3D alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Alto-Shaam 500-3D, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Alto-Shaam service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Alto-Shaam 500-3D.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Alto-Shaam 500-3D item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    MN-29742 (R e v . 1) • 04/13 p r i n t e d i n u . s . a . Drawer Warmers Electric Models : 500-1D, 1DN 500-2D, 2DN 500-3D, 3DN   • InstallatIon  • operatIon • MaIntenance W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 USA PHONE: 262.251.3800 • 800.558.8744 USA / C A N A D A FAX: 262.2[...]

  • Page 2

    MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • b Delivery ............................................................................. 1 Unpacking ........................................................................ 1 Safety Procedures and Precautions ................................. 2 Installation Ins[...]

  • Page 3

    MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 1 DELIVERY This Alto-Shaam appliance has been thoroughly tested and inspected to ensure only the highest quality unit is provided. Upon receipt, check for any possible shipping damage and report it at once to the delivering carrier. See Transportation Damage and[...]

  • Page 4

    MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 2 CAUTION Used to indicate the presence of a hazard that can or will cause minor personal injury, property damage, or a potential unsafe practice if the warning included with this symbol is ignored. CAUTION Used to indicate the presence of a hazard that can or w[...]

  • Page 5

    MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 3 SITE INSTALLATION This Alto-Shaam appliance must be installed in a location that will permit it to function for its intended purpose and to allow adequate clearance for ventilation, proper cleaning, and maintenance access. 1. This appliance must be installed o[...]

  • Page 6

    MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 4 12-5/16" (312mm) 24-5/8" (624mm) 43-3/8" (1101mm) 24-7/8" (631mm) 26-1/8" (664mm) 25-7/8" (657mm) 11-5/8" (296mm) 18-15/16" (481mm) 500-1D 500-2D 500-3D Electrical Connection 6-3/4" (171mm) FOR LEG ST AND OR 5"[...]

  • Page 7

    MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 5 26-1/8" (664mm) 31-3/16" (792mm) 11-5/8" (296mm) 18-15/16" (481mm) 500-1D 500-2D 500-3D Electrical Connection 6-3/4" (171mm) FOR LEG ST AND OR 5" (127mm) CASTER ST AND ASSEMBL Y 4-7/8" (121mm) FOR CASTER ST AND ASSEMBL Y WITH[...]

  • Page 8

    MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 6 1. An identification tag is permanently mounted on the cabinet. 2. Plug cabinet into a properly grounded receptacle ONLY, positioning the unit so the power supply cord is easily accessible in case of an emergency. Arcing will occur when connecting or disconnec[...]

  • Page 9

    MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 7 This appliance is intended for use in commercial establishments where all operators are familiar with the purpose, limitations, and associated hazards of this appliance. Operating instructions and warnings must be read and understood by all operators and users[...]

  • Page 10

    MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 8 1 . PREHEAT AT 200°F (93°C) FOR 30 MINUTES BEFORE LOADING FOOD. Push power switch to “ON” position. The unit will begin operating at the previous set temperature. 2. Press the Up or Down Arrow Keys to 200°F (93°C). Pressing and releasing the Arrow Keys[...]

  • Page 11

    MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 9 GENERAL HOLDING GUIDELINES Chefs, cooks and other specialized food service personnel employ varied methods of cooking. Proper holding temperatures for a specific food product must be based on the moisture content of the product, product density, volume, and pr[...]

  • Page 12

    MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 10 CAUTION TO PROTECT STAINLESS STEEL SURFACES, COMPLETELY AVOID THE USE OF ABRASIVE CLEANING COMPOUNDS, CHLORIDE BASED CLEANERS, OR CLEANERS CONTAINING QUATERNARY SALTS. NEVER USE HYDROCHLORIC ACID (MURIATIC ACID) ON STAINLESS STEEL. NEVER USE WIRE BRUSHES, MET[...]

  • Page 13

    MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 11 THOROUGHLY CLEAN DAILY : 1. Disconnect unit from power source, and let cool. 2. Remove, cover or wrap, and refrigerate food. 3. Remove drawer pans and clean separately. The drawer assembly is completely removable. Remove from the cabinet and clean to prevent [...]

  • Page 14

    MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 12 Food fl avor and aroma are usually so closely related that it is diffi cult, if not impossible, to separate them. There is also an important, inseparable relationship between cleanliness and food fl avor. Cleanliness, top operating effi ciency, and appearan[...]

  • Page 15

    MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 13 THERMOSTAT ACCURACY The electronic thermostat is a precise instrument and is designed to offer trouble free service. If you suspect the temperature inside the holding compartment does not match the temperature indicated on the digital display, follow the inst[...]

  • Page 16

    MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 14 TROUBLE SHOOTING - ELECTRONIC CONTROL INSTALLATION Code Description Possible Cause E-10 Cavity air sensor shorted Cavity air sensor reading < 5°F. Verify sensor integrity. See sensor test instructions below. E-11 Cavity air sensor open Cavity air sensor r[...]

  • Page 17

    MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 15 SERVICE 1 23 4 5 6 27 26 25 22 21 24 10 19 20 16 15 18 17 11 12 13 14 9 7 8 23 SERVICE VIEW - EXTERIOR 500-2D Shown Part numbers and drawings are subject to change without notice.[...]

  • Page 18

    MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 16 MODEL > 500-1D 500-2D 500-3D ITEM DESCRIPTION PART NO. QTY PART NO. QTY PART NO. QTY 1 TOP COVER 1012473 1 1012473 1 1012473 1 2 REAR TRIM 1012665 1 1012674 1 1012446 1 3 RIVET , BLIND, #44, S/S 28 RI-2100 24 RI-2100 28 RI-2100 30 4 GASKET ADHESIVE 0.125 x[...]

  • Page 19

    MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 17 SERVICE 3 4 5 1 2 12 11 10 6 13 8 7 9 SERVICE VIEW - DRAWER ASSEMBLY (5013915) 500-D Part numbers and drawings are subject to change without notice. ITEM DESCRIPTION PART NO. QTY 1 WASHER, 1/4" LOCK WS-2294 2 2 NUT 1/4-20 NC ACORN #18-8 S/S NU-2187 2 3 P[...]

  • Page 20

    MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 18 SERVICE 4 6 5 1 2 11 12 10 17 18 19 20 23 24 25 26 27 28 29 21 22 13 14 15 16 3 9 7 8 SERVICE VIEW - EXTERIOR 500-1DN Shown Part numbers and drawings are subject to change without notice.[...]

  • Page 21

    MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 19 SERVICE MODEL > 500-1DN 500-2DN 500-3DN ITEM DESCRIPTION PART NO. QTY PART NO. QTY PART NO. QTY 1 TOP COVER 1012779 1 1012779 1 1012779 1 2 GASKET ADHESIVE 0.125 x 0.375 [lin ft] GS-23622 8 GS-23622 8 GS-23622 8 3 BUSHING, STRAIGHT , STRAIN RELIEF BU-3964 [...]

  • Page 22

    MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 20 SERVICE 7 6 5 9 10 12 14 13 4 1 8 3 2 11 SERVICE VIEW - DRAWER ASSEMBLY (5014435) 500-DN Part numbers and drawings are subject to change without notice. Item #10 must be order ed when installing item #11 ITEM DESCRIPTION PART NO. QTY 1 RAIL, P AN, LEFT -HAND [...]

  • Page 23

    MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 21 SERVICE 6 5 8 7 4 3 1 2 10 9 SERVICE VIEW - ELECTRICAL Part numbers and drawings are subject to change without notice. ITEM DESCRIPTION PART NO. QTY 1 BUSHING, 3/8" HOLE BU-3419 1 2 ELECTRIC CHASSIS 5014441 1 3 WASHER, INT . LOCK WS-2467 1 4 SCREW , 10-3[...]

  • Page 24

    MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 22[...]

  • Page 25

    MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 23[...]

  • Page 26

    MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 24[...]

  • Page 27

    TRANSPORTATION DAMAGE and CLAIMS All Alto-Shaam equipment is sold F.O.B. shipping point, and when accepted by the carrier, such shipments become the property of the consignee. Should damage occur in shipment, it is a matter between the carrier and the consignee. In such cases, the carrier is assumed to be responsible for the safe delivery of the me[...]