Altinex 400-0026-004 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Altinex 400-0026-004, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Altinex 400-0026-004 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Altinex 400-0026-004. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Altinex 400-0026-004 should contain:
- informations concerning technical data of Altinex 400-0026-004
- name of the manufacturer and a year of construction of the Altinex 400-0026-004 item
- rules of operation, control and maintenance of the Altinex 400-0026-004 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Altinex 400-0026-004 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Altinex 400-0026-004, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Altinex service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Altinex 400-0026-004.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Altinex 400-0026-004 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    MATRIX SWITCHERS HOMERUN SERIES MATRIX SWITCHERS USER’S GUIDE MANUAL PART NUMBER: 400-0026-004 PRODUCT REVISION: 2[...]

  • Page 2

    MATRIX SWITCHERS 1 INTRODUCTION Thank you for purchasing a HOMERUN Series Matrix Switcher. We are sure you will find it to be reliable and simple to use. The HOMERUN Series Matrix Switchers are designed using state-of-the-art technology and offer a unique combination of features not available anywhere else. We are committed to providing our custome[...]

  • Page 3

    MATRIX SWITCHERS 2 PRECAUTIONS/SAFETY WARNINGS 1 Please read this manual carefully before using your HOMERUN Series Matrix Switcher. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your HOMERUN Series Matrix Switcher and to prevent fire and shock hazard. Please read them carefully and heed all w[...]

  • Page 4

    MATRIX SWITCHERS 3 ABOUT YOUR HOMERUN MATRIX SWITCHER 2 The HOMERUN Matrix Switcher is a state-of-the-art product designed to route up to 16 inputs to 16 outputs. The HOMERUN Matrix Switcher consists of 1-U high rack wide modules. Combining multiple modules can create larger configurations. The HOMERUN Switcher is designed to switch Composite Video[...]

  • Page 5

    MATRIX SWITCHERS 4 DIAGRAM OF FRONT/BACK PANEL 4[...]

  • Page 6

    MATRIX SWITCHERS 5[...]

  • Page 7

    MATRIX SWITCHERS 6 IN OUT LOOP CONTROL IN OUT LOOP CONTROL IN OUT LOOP CONTROL APPLICATION DIAGRAM 5 Single Video/Sync module can be used as a Composite Video or TTL/ECL Matrix Switcher. Two modules interconnected together can be used as an S-Video Matrix Switcher. Three interconnected modules can route any analog component video signals such as RG[...]

  • Page 8

    MATRIX SWITCHERS 7 INSTALLING YOUR SWITCHER 6 Step 1. Stack together the modules that are required to form a matrix for switching the desired signals. Allow 1-U rack space every 4 units for air circulation. This will reduce heat build up and will prolong the life of your system. 16x16 RGBHV + Stereo Audio System Step 2. Connect the HOMERUN modules [...]

  • Page 9

    MATRIX SWITCHERS 8 Figure 2: HOMERUN Video Module OPERATION 7 7.1 BACK PANEL MANUAL CONTROL Two switches (F1 and F2) are provided in the center of the back panel as shown below. During installation or troubleshooting these switches provide a simple manner of controlling the module from the back of the rack. Figure 3: Back Panel control switches SEL[...]

  • Page 10

    MATRIX SWITCHERS 9 PRESS FUNCTION F1 Selects input (confirmed by “ON” LED) F2 Selects output (confirmed by “ON” LED) F1+HOLD Connects selected input to selected output F2+HOLD Connects selected input to selected output F1+F2 together (Press & Release) Resets selected input and output channels F1+F2+HOLD (Press & Hold) Resets switche[...]

  • Page 11

    MATRIX SWITCHERS 10 This command sets a unique ID number to each HOMERUN module and allows control of multiple modules through a single RS-232 port . In order to control multiple modules independently with one RS-232 port, the unit ID is used. Setting the unit ID allows a user to send the same command to multiple modules, but the module processes t[...]

  • Page 12

    MATRIX SWITCHERS 11 This command is used for programming the switcher. It should not be used as part of a program to operate the switcher. There is no feedback provided for this command. [ IkkOXXS] kk = input offset; 00 to 96 This command sets the maximum number of inputs on the HOMERUN Switcher without changing the maximum number of outputs. This [...]

  • Page 13

    MATRIX SWITCHERS 12 2. Output offset is zero for both units. 3. The input offset must be set for all units except the first one. The offset for input should be the same as the last input number of the previous unit. 4. The number of inputs available on second unit for direct connection is the difference between the maximum number of inputs of the s[...]

  • Page 14

    MATRIX SWITCHERS 13 [ERR], just the version number; for example [3.2] or [3.5]. [VISn] n = 1 Enable VIS n = 0 Disable VIS This command enables or disables vertical interval switching, if the option is installed on the HOMERUN Matrix Switcher. 7.2.3 CONTROL COMMANDS These control commands are used for controlling the switcher. They can be part of a [...]

  • Page 15

    MATRIX SWITCHERS 14 command. The [UIDnE] command should be used to disable all levels and enable only the unit that needs to be controlled. This command can not be used with unit ID 0 or 1. For example, at power up, all units can be controlled. To control level 3 only, issue the command - [UID3E]. [IkkOmm] kk = input number 01 to 16 mm = output num[...]

  • Page 16

    MATRIX SWITCHERS 15 This command selects the output to control. Once the output number to be controlled is set through this command, this output can be connected to several inputs. If output 00 is selected then disconnect all inputs to be specified through the connect command, [IkkOXXC]. [IkkOXXC] kk = input number 01 to 16 This command connects a [...]

  • Page 17

    MATRIX SWITCHERS 16 where mm is the current input connected to the specified output. For example, the [IXXO02] command can return 04 indicating that input #4 is currently connected to output #2. [IXXO03] can return 00, which means that nothing is currently connected to output #3. [SW] - Switch The switch command immediately connects inputs and outp[...]

  • Page 18

    MATRIX SWITCHERS 17 Press the RECALL button and hold for 2 seconds. The unit will beep and switch into the recall mode. This mode is indicated by the RECALL LED flashing slowly. Press INPUT 1 through INPUT 16 to recall the desired memory location. Output buttons do not work anymore in this operation. Press and hold the RECALL button for 2 sec. agai[...]

  • Page 19

    MATRIX SWITCHERS 18 Set Baud Rate: Baud rate determines communication between the control system and HOMERUN Matrix Switchers and also the rate between individual modules of the HOMERUN . Setting all interconnected modules to the same baud rate is essential for proper operation of the complete system. It is recommended that baud rate is changed for[...]

  • Page 20

    MATRIX SWITCHERS 19 end of the cable is connected to the RS-232 port of the HOMERUN Matrix Switcher. ALTINEX HOMERUN CONTROL PROGRAM 1 Follow Step 1 of previous option. 2. Load the HOMERUN control program on WINDOW 95 from the START UP button, PROGRAM option and Altinex tab. 3 Go to the SETUP TAB and verify that current baud rate is set at 2400 bau[...]

  • Page 21

    MATRIX SWITCHERS 20 to be saved in any of the 16 available memories. RECALL Allows recalling the saved connections from memory 01 through 16. SPACE Reserved for future use. DELETE Reserved for future use. CLEAR Reserved for future use. Recall 01,02,03 Allows the end user to recall the first three settings by pressing just one button. ENTER To compl[...]

  • Page 22

    MATRIX SWITCHERS 21 ACCESSORIES 8 Model No. Description RACK MOUNTING BRACKETS DA1292RM 19”-1U Rack mount ears for rack wide units TABLE MOUNT BRACKETS TM1277 3U High, 1 Rack-Wide 4 BNC TO 4 BNC COAXIAL CABLE CB4100MR Bulk cable 4 coaxes (500 ft minimum) CB4106MR 6 feet CB4112MR 12 feet CB4125MR 25 feet CB4150MR 50 feet CB4175MR 75 feet CB41100MR[...]

  • Page 23

    MATRIX SWITCHERS 22 at the same time, can this be done with this product? a challenge to connect. 8 Can I use contact closure to control the switcher? No. The unit should be controlled using RS-232 commands or through the optional CP-01/CP-02/CP-03 9 Is the HOMERUN Switcher capable of controlling various projectors? It is not recommended in large s[...]

  • Page 24

    MATRIX SWITCHERS 23 DOWNLOAD section from the Altinex website www.altinex.com . ALTINEX POLICY 11 11.1 LIMITED WARRANTY Altinex warrants that its products and cables are free from defects in materials under normal use and service. This warranty is limited to repairing at company’s factory any part or parts of the product, which upon company’s e[...]