Allied Telesis 86222-10 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Allied Telesis 86222-10, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Allied Telesis 86222-10 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Allied Telesis 86222-10. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Allied Telesis 86222-10 should contain:
- informations concerning technical data of Allied Telesis 86222-10
- name of the manufacturer and a year of construction of the Allied Telesis 86222-10 item
- rules of operation, control and maintenance of the Allied Telesis 86222-10 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Allied Telesis 86222-10 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Allied Telesis 86222-10, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Allied Telesis service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Allied Telesis 86222-10.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Allied Telesis 86222-10 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Simply connecting the world Patch Release Note Patch 86222-10 For Rapier Switches and AR800 Series Modular Switching Routers Intr oduction This patch rel ease note lists the issues addres sed and enhancements made in patch 86222-10 for Software Release 2.2. 2 on existing models of Rapier L3 managed switches and AR800 Series L3 modular switching rou[...]

  • Page 2

    2 Patch Release Note Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J Some switch chip r egister settings have been optimised to impr ove the provision of CoS with the newer r evision of switching silicon. Featur es in 86222-09 Patch file details for Patch 86222-0 9 are listed in T able 2. Patch 86222-09 includes all issues reso lved[...]

  • Page 3

    Patch 86222-10 For Rapier Switches a nd AR800 Series Modula r Sw itching Routers 3 Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J A configuration pr oblem prevented trunk ing of gigabit ports at 100Mbit speeds. This issue has been resolved. The A39 gigabit copper uplink reverted to autonegotiation after a r est art, even if it was [...]

  • Page 4

    4 Patch Release Note Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J The dot1dBridge MIB implementation now complies with RFC1493. Featur es in 86222-07 Patch file details for Patch 86222-0 7 are listed in T able 4: T able 4: Patch file details for Patch 8622 2-07 Patch 86222-07 includes all issues reso lved and e nhancem ents relea[...]

  • Page 5

    Patch 86222-10 For Rapier Switches a nd AR800 Series Modula r Sw itching Routers 5 Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J Debug messages ar e no longer generate d when a Q.931 Advise of Charge Notification message is re ceived. TCP sessions would g et stuck in the FINW AIT2 state if the r emote host did not send a FIN messa[...]

  • Page 6

    6 Patch Release Note Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J The T rigger Facility was generating a tr ap with variable { 0 0 }, and was not documented in the A TI enterprise MIB. This issue has been resolved. The MIB object triggerLastT riggerActivated ({ enterprises(1) alliedT elesyn(207) mibObjects(8) br outerMib(4) atrou[...]

  • Page 7

    Patch 86222-10 For Rapier Switches a nd AR800 Series Modula r Sw itching Routers 7 Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J A switch port that was transmitting STP B PDUs and also mirr oring its transmit traf fic to the mirror port caused a fatal err or . This issue has been res ol v ed . Featur es in 86222-06 Patch file deta[...]

  • Page 8

    8 Patch Release Note Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J A39 copper uplink modules in the Rapier G6 sometimes experienced spurious link up or link down ev ents. This issue has been r e solved. The enterprise MIB now supports objects for power supply monitoring. Certificates containing GeneralisedT ime with the year in YY[...]

  • Page 9

    Patch 86222-10 For Rapier Switches a nd AR800 Series Modula r Sw itching Routers 9 Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J When lar ge numbers of sessions were being handled the firewall would become overly aggr essive in r estricting new sessions. The Ac tive TCP Opens field in the output of the SHOW FIREW ALL POLICY would [...]

  • Page 10

    10 Patch Release Note Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J correctly when only one byte has been specified. The CRL update time is now displayed correctly in hours. If the username and password parameters ar e present the location parameter must be pr esent and appear before the username and password parameters. The DHCP [...]

  • Page 11

    Patch 86222-10 For Rapier Switches a nd AR 800 Series Modular Switching Routers 11 Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J DNS response packets wi th corrupt length fields were causing a fat al error . This issue has been r esolved. IP NA T caused a fatal error when an ARP wait timer timed out and tried to send a host unr ea[...]

  • Page 12

    12 Patch Release Note Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J The SHOW CPU command sometimes di splayed incorrect CPU util isation figures. T y pically a value of about 74% was reported when in fact the CPU was almost idle. Thi s issue has been r esolved. Port parameters can now be set corre ctly using the Laye r 3 Switch GU[...]

  • Page 13

    Patch 86222-10 For Rapier Switches a nd AR 800 Series Modular Switching Routers 13 Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J Repeated addition and deletion of an addr ess with the V ALID parameter set to or fr om an IPV6 interface caused a fatal err or . This issue has been corrected. The V ALID parameter specifies the li fe o[...]

  • Page 14

    14 Patch Release Note Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J[...]