Air King VAL30SS manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Air King VAL30SS, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Air King VAL30SS one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Air King VAL30SS. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Air King VAL30SS should contain:
- informations concerning technical data of Air King VAL30SS
- name of the manufacturer and a year of construction of the Air King VAL30SS item
- rules of operation, control and maintenance of the Air King VAL30SS item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Air King VAL30SS alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Air King VAL30SS, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Air King service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Air King VAL30SS.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Air King VAL30SS item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    www .airkinglimited.com 60804020 Rev A. 4-05 1 of 20 READ AND SA VE THESE INSTRUCTIONS READ CAREFULL Y BEFORE A TTEMPTING TO ASSEMBLE, INST ALL, OPERA TE OR MAINT AIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMA TION. F AILURE TO COMPL Y WITH INSTRUCTIONS COULD RESUL T IN PERSONAL INJURY AND/OR PROPER TY DAMAGE[...]

  • Page 2

    drill holes into wall using a 1/4" drill bit. Press the included wall anchors into the drilled holes (one for each hole). Install two 3.19 x 32 mm screws, leaving a 1/8" gap between the screw head and the wall. Line up the keyholes in the hood with the screws and position in place. Hang the hood over the keyhole anchors and verify that th[...]

  • Page 3

    www .airkinglimited.com 60804020 Rev A. 4-05 2. Connect the ducting to the duct collar and secure in place using tape to seal all joints (Figure 4) . NOTE: The duct connector is 5.8" in diameter (for 6" round ducting) and the center is located 3-3/16" inches from the back wall. CAUTION: ALWAYS DUCT THE FAN TO THE OUTSIDE THROUGH A WA[...]

  • Page 4

    60804020 Rev A. 4-05 www .airkinglimited.com 4 of 20 Figure 9 Charcoal Filter Figure 10 3. T urn switches to the OFF ( ) position and restore power . T est that the light and the fan are operating properly . 4. If there is any vibration noise, check for the source and try to tighten fasteners or adjust the tape to make a tighter connection or seal.[...]

  • Page 5

    LIMITED WARRANTY All products manufactured by Air King Limited are warranted for one year from the date of purchase against defects in workmanship and/or material. In addition, all ventilating/exhaust fans, heaters, combination fan lights and/or heaters, and range hoods are guaranteed for five years from the date of purchase against defects in work[...]

  • Page 6

    www .airkinglimited.com # Qty . Description Replacement Part # 24 1 Fan Blade 5S6113071 25 1 Motor Housing 5S6113092 26 1 Motor Connection Box 5S6113093 27 1 Capacitor 5S6113094 28 1 T erminal Strip 5S6113095 29 1 Wire 5S6113096 30 2 Filter Screw (36” models Qty. 3) 5S6113029 31 2 Filter (36” models Qty. 3) 5S6113028 32 2 Lamp Holder 5S6113097 [...]

  • Page 7

    www .airkinglimited.com 7 of 20 60804020 Rev A. 4-05[...]

  • Page 8

    www .airkinglimited.com 60804020 Rev A. 4-05 8 of 20 Series V alencia™ Hotte de Cuisine CONSER VER CES INSTRUCTIONS INSTRUCTIONS IMPOR T ANTES – MANUEL D’OPÉRA TION A VERTISSEMENT : POUR RÉDUIRE LES RISQUES D’INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURES PERSONNELLES OBSERVER CE QUI SUIT : 1. Lire toutes les instructions avant d’install[...]

  • Page 9

    1. Référez-vous au dessin de trou de montage fourni avec l’unité. Localiser et marquer la position des trous en poire du haut de l’unité sur le mur et percer les trous dans le mur à l’aide d’un trépan de 0,64 cm (1/4 po). Presser les ancrages au mur dans les trous percés (un pour chaque trou). Installer les deux vis de 3,19 x 32 mm, [...]

  • Page 10

    www .airkinglimited.com 60804020 Rev A. 4-05 2. Raccorder le conduit au collet de conduit et le serrer en place en utilisant du ruban adhésif pour sceller tous les joints (Figure 4) . REMARQUE : Le raccord de conduit est d’un diamètre de 14,73 cm (5,8 po) (pour des conduits ronds de 15,24 cm (6 po) et le centre est situé à 7,78 cm (3 1/16 po)[...]

  • Page 11

    60804020 Rev A. 4-05 www .airkinglimited.com 11 of 20 Figure 10 3. Mettre les commutateurs à la position Eteint (OFF) ( ) et remettre l’alimentation. T ester pour s’assurer que la lampe et le ventilateur fonctionnent normalement. 4. En cas de bruit de vibration, vérifier pour la source et tenter de resserrer les attaches ou d’ajuster le rub[...]

  • Page 12

    GARANTIE LIMITÉE T ous les produits fabriqués par Air King Limited sont garantis pour un an à partir de la date d’achat contre les défauts de main d’œuvre et/ou de matériel. De plus, tous les ventilateurs / évacuateurs, chaufferettes, combinés ventilateur/ lumière et/ou les chaufferettes et les hottes de cuisine sont garantis pour cinq[...]

  • Page 13

    www .airkinglimited.com # de pièce de # Qté. Description r emplacement 24 1 Agrafe d’hélice 5S6113071 25 1 Châssis du moteur 5S6113092 26 1 B oît e d e co nne xio n d u mo teu r 5S6113093 27 1 Condensateur 5S6113094 28 1 Bor nie r 5S6113095 29 1 Fil 5S6113096 30 2 Vis du filtre quantité sur les modèles de 36 po : 3 5S6113029 31 2 Filtre qu[...]

  • Page 14

    www .airkinglimited.com 14 of 20 60804020 Rev A. 4-05[...]

  • Page 15

    www .airkinglimited.com 60804020 Rev A. 4-05 15 of 20 Serie V alencia™ Campana de Extracción INSTRUCCIONES IMPOR T ANTES – MANUAL DE OPERACIÓN ADVERTENCIA: P ARA REDUCIR EL RIESGO DE INCENDIO, CHOQUE ELÉCTRICO Y HERIDAS A PERSONAS, OBEDEZCA LO SIGUIENTE: 1. Lea todas las instrucciones antes de instalar o usar la campana de extracción. 2. Us[...]

  • Page 16

    1. Consulte el dibujo del agujero de montaje provisto con la unidad. Ubique y marque las posiciones del ojo de cerradura superior en la pared y taladre agujeros en la pared usando una broca de taladro de 1/4" pulgada. Oprima las anclas de pared incluidas dentro de los agujeros taladrados (una para cada agujero). Instale dos tornillos de 3,19 x[...]

  • Page 17

    www .airkinglimited.com 60804020 Rev A. 4-05 2. Conecte la tubería a la abrazadera de la tubería y asegure en su lugar usando cinta para sellar todas las juntas (Figura 4) . NOT A: El conector de la tubería mide 5,8 pulgadas de diámetro (para tuberías redondas de 6") y el centro está ubicado a 3-3/16" pulgadas de la pared posterior [...]

  • Page 18

    60804020 Rev A. 4-05 www .airkinglimited.com 18 of 20 3. Coloque los interruptores en la posición AP AGADO / OFF ( ) y reconecte el suministro eléctrico. Compruebe que la luz y el ventilador estén funcionando correctamente. 4. Si hay algún ruido de vibración, controle la fuente del mismo y trate de asegurar los sujetadores o de ajustar la cint[...]

  • Page 19

    www .airkinglimited.com Instalador: _______________________________________________________ Fecha de Instalación: _____________________________________ Lugar de Compra: __________________________________________________ Número de Modelo: ______________________________________ 19 of 20 60804020 Rev A. 4-05 Guía de Solución de Problemas Problema [...]

  • Page 20

    www .airkinglimited.com # Cant. De scripción Número de Repuesto 24 1 Agrafe d’hélice 5S6113071 25 1 E stu ch e de l mo tor 5S6113092 26 1 C aja de con exi ón d el mot or 5S6113093 27 1 Capacitor 5S6113094 28 1 F ran ja ter min al 5S6113095 29 1 Cable 5S6113096 30 2 T ornillo del filtro (Modelos de 36 pulgadas Cantidad 3) 5S6113029 31 2 Filtro[...]