Agilent Technologies 60502B manual

1
2
3
4
5
6
7
8
9
10
11

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Agilent Technologies 60502B, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Agilent Technologies 60502B one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Agilent Technologies 60502B. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Agilent Technologies 60502B should contain:
- informations concerning technical data of Agilent Technologies 60502B
- name of the manufacturer and a year of construction of the Agilent Technologies 60502B item
- rules of operation, control and maintenance of the Agilent Technologies 60502B item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Agilent Technologies 60502B alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Agilent Technologies 60502B, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Agilent Technologies service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Agilent Technologies 60502B.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Agilent Technologies 60502B item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    OPERATING MANUAL 300 WATT ELECTRONIC LOAD MODULE Agilent Model 60502B FOR MODULES WITH SERIAL NUMBERS: 3118A-00101 AND ABOVE Agilent Part No. 60502-90008 Printed in U.S.A. Microfiche No. 60502-90009 June, 1991[...]

  • Page 2

    DECLARATION OF CONFORMITY according to ISO/IEC Guide 22 and EN 45014 Manufacturer’s Name : Agilent Technologies Manufacturer’s Address: New Jersey Division 140 Green Pond Road Rockaway, NJ 07866 U.S.A. declares that the product Product Name: Load mainframe and modules Model Number(s): Agilent 6050A, 6051A mainframes with modules Agilent 60501A/[...]

  • Page 3

    1 300-Watt Module About This Manual This manual provides information for the Agilent 60502B 300-Watt Electronic Load Module. It is designed as a supplement to the Agilent 6050A/6051A Multiple Input Mainframe Electronic Load Operating Manual (part number 06050- 90001). Four tables provide the following module-specific information: Table 60502-1 list[...]

  • Page 4

    2 Table 60502-1. Specification and Supplemental Characteristics SPECIFICATIONS DC Input Rating: Current: 0 to 60 A Voltage : 3 V to 60 V (minimum dc operation from 0 to 2 V for 0 to 60 A) Power: 300 W at 40 ° C (derated to 225 W at 55 ° C) A. OPERATING CHARACTERISTICS B. DERATED CURRENT DETAIL Constant Current Mode: Ranges: 0 to 6 A; and 0 to 60 [...]

  • Page 5

    3 Table 60502-1 Specifications and Supplemental Characteristics (continued) Transient Operation: Continuous Mode Frequency Range: 0.25 Hz to 10 kHz Frequency Resolution: 4% Frequency Accuracy: 3% Duty Cycle Range: 3% to 97% (0.25 Hz to 1 kHz); 6% to 94% (1 kHz to 10 kHz) Duty Cycle Resolution: 4% Duty Cycle Accuracy: 6% of setting ± 2% Pulsed Mode[...]

  • Page 6

    4 Table 60502-1 Specifications and Supplemental Characteristics (continued) External Analog Programming 0 to 10 V (dc or ac): Bandwidth: 10 kHz (3 db frequency) Accuracy: ± 4.5% ± 75 mA (0 to 6 A range) ± 4.5% ± 250 mA (0 to 60 A range) ± 0.8% ± 200 mV (0 to 60 V range) Temperature Coefficient: 100 ppm/ ° C ± 6 mA/ ° C (current ranges) 100[...]

  • Page 7

    5 Table 60502-1 Specifications and Supplemental Characteristics (continued) Current Slew Rate:* Rate # 60 A Range Step 6 A Range Step Transition Time 1 1 A/ms 0.1 A/s 8.0 ms 2 2.5 A/ms 0.25 A/s 3.2 ms 3 5 A/ms 0.5 A/s 1.6 ms 4 10 A/ms 1 A/ms 800 µ s 5 25 A/ms 2.5 A/ms 320 µ s 6 50 A/ms 5 A/ms 160 µ s 7 0.1 A/ µ s 10 A/ms 80 µ s 8 0.25 A/ µ s [...]

  • Page 8

    6 Table 60502-1 Specifications and Supplemental Characteristics (continued) Source Turn-On Current Overshoot: Less than 10% of final value (in CC and CR modes when connected to power supplies with voltage rise times of greater than 500 µ s). Programmable Short Circuit: 0.033 Ω (0.002 Ω typical) Programmable Open Circuit: 20 k Ω (typical) Dri[...]

  • Page 9

    7 Table 60502-2. Programming Ranges (continued) Function Front Panel Front Panel HPSL Command Range of Values Key Display (Short Form) Transient Operation Set Frequency FREQ value "TRAN:FREQ value" 0.25 Hz to 10 kHz Set Duty Cycle (shift) DCYCLE value "TRAN:DCYC value" 3-97% (0.25 Hz-1 kHz) 6-94% (1 kHz-10 kHz) *Set Pulse Width [...]

  • Page 10

    8 Table 60502-4. Calibration Information Ranges and Calibration Points Variables Variables Value Power Supply Settings Current Shunt High Current Range Hi_curr_rng 60 5 V/61 A 100 A High Current Offset Hi_curr_offset 0.0282 Low Current Range Lo_curr_rng 6 5 V/10 A 15 A Low Current Offset Lo_curr_offset 0.0197 Voltage Range N/A N/A 61 V/5 A N/A Volt[...]

  • Page 11

    9 Agilent Sales and Support Office For more information about Agilent Technologies test and measurement products, applications, services, and for a current sales office listing, visit our web site: http://www.agilent.com/find/tmdir You can also contact one of the following centers and ask for a test and measurement sales representative. United Stat[...]