Agilent Technologies 60501B manual

1
2
3
4
5
6
7
8
9
10
11

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Agilent Technologies 60501B, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Agilent Technologies 60501B one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Agilent Technologies 60501B. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Agilent Technologies 60501B should contain:
- informations concerning technical data of Agilent Technologies 60501B
- name of the manufacturer and a year of construction of the Agilent Technologies 60501B item
- rules of operation, control and maintenance of the Agilent Technologies 60501B item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Agilent Technologies 60501B alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Agilent Technologies 60501B, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Agilent Technologies service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Agilent Technologies 60501B.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Agilent Technologies 60501B item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    OPERATING MANUAL 150 WATT ELECTRONIC LOAD MODULE Agilent Model 60501B FOR MO DULES WITH SERIAL NUMBERS: 3118A -00101 A ND A BOVE A gilent Part No. 60501-90009 Printed in U.S.A . Microf iche No. 60501-90010 June, 1991[...]

  • Page 2

    DECLA RA TION OF CONFORMI TY according to IS O/IEC G uide 22 and E N 45014 Manufacturer’s Name : Agilent Tec hnologies Manuf acturer’s A ddress: New Jersey Divi sion 140 Green Pond Road Rock away , NJ 07866 U.S.A. declares that the pr oduct Product Name: Load mainf ram e and m odules Model Number(s): Agilent 6050A, 6051A mainf ram es with m odu[...]

  • Page 3

    1 150-Watt Module About This Manual This m anual provides in form ation for t he Ag ilent 60501B 150- Watt Electron ic Load Modul e. It is desig ned as a supplem ent to the A gilent 6050A /6051A Mu ltiple Input Mainf rame Electron ic Load Operating Man ual (part nu mber 06050- 90001). Four tabl es provide th e follow ing modu le-specif ic inf ormat[...]

  • Page 4

    2 Table 60501-1. Specification and Supplemental Characteristics SPECIFICA TIO NS DC Input Rating: Current: 0 to 30 A Voltage : 3 to 60 V (min imu m dc operat ion from 0 to 2 V for 0 t o 30 A) Pow er: 150 W at 40 ° C (derated to 112 W at 55 ° C) A . OPERA TING CHARA CTERISTICS B. DERA TED CURRENT DETAIL Constant Current Mode: Ranges: 0 to 3 A; and[...]

  • Page 5

    3 Table 60501-1 Specifications and Supplemental Characteristics (continued) Transient Operat ion: Continuous Mode Frequency Range: 0.25 Hz to 10 kHz Frequency Resolution: 4% Frequency A ccuracy : 3% Duty Cy cle Range: 3% to 97% (0.25 Hz to 1 k Hz); 6% to 94% (1 k Hz to 10 kHz) Duty Cy cle Resolution: 4% Duty Cycle A ccuracy : 6% of set ting ± 2% P[...]

  • Page 6

    4 Table 60501-1 Specifications and Supplemental Characteristics (continued) External A nalog Programming 0 to 10 V (dc or ac): Bandwidth: 10 kHz (3 db freque ncy ) A ccuracy: ± 4.5% ± 40 m A (0 t o 3 A rang e) ± 4.5% ± 130 m A (0 to 30 A range) ± 0.8% ± 200 mV (0 to 60 V range) Temperature Coeffic ient: 100 ppm/ ° C ± 3 mA/ ° C (cu rrent r[...]

  • Page 7

    5 Table 60501-1 Specifications and Supplemental Characteristics (continued) Current Slew Rate:* Rate # 30 A Range Step 3 A Range Step Transition T ime 1 0.5 A/m s 0.05 A/s 8.0 ms 2 1.2 A/m s 0.12 A/s 3.2 ms 3 2.5 A/m s 0.25 A/m s 1.6 ms 4 5 A/m s 0.5 A/m s 800 µ s 5 12 A/m s 1.2 A/m s 320 µ s 6 25 A/m s 2.5 A/m s 160 µ s 7 0.05 A/ µ s 5 A /m s [...]

  • Page 8

    6 Table 60501-1 Specifications and Supplemental Characteristics (continued) Source Turn-On Current Overshoot: Less than 10% of fin al value (in CC and CR m odes w hen connected to pow er supplies with voltage rise times of greater than 500 µ s). Programmable Shor t Circuit: 0.066 Ω (0.04 Ω typical) Programmable Open Circuit: 20 k Ω (ty pical[...]

  • Page 9

    7 Table 60501-2. Programming Ranges (continued) Transient O peration Set Frequency FREQ value " T RAN:FREQ value" 0.25 Hz to 10 kHz Set Duty Cy cle (shif t) DCYCLE v alue "TRAN: DCYC va lue" 3-97% (0.25 Hz- 1 kHz) 6-94% (1 k Hz-10 kH z) *S et Puls e Width "TRAN:TWID valu e" 0.00005 to 4 s Trigger Operat ion *S et Trigg[...]

  • Page 10

    8 Table 60501-4. Calibration Info rmation Ranges and Calibration Points Variables Variables Value Power Supply Settings Current Shunt High C urrent R ange Hi_cu rr_rng 30 5 V/31 A 100 A High C urrent Of fset Hi_curr_off set 0.013 Low Cu rrent Ran ge Lo_curr_rn g 3 5 V/10 A 15 A Low Curren t Off set L o_curr_off set 0.013 Voltage Range N/A N/A 61 V/[...]

  • Page 11

    9 Agilent Sales and Support Office For more information about Agilent Technologies test and measurement products, applications, services, and for a current sales office listing, visit our web site: http://www.agilent.com/find/tmdir You can also contact one of the following centers and ask for a test and measurement sales representative. United Stat[...]