AGFA ANAPURNA M4F M4F manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of AGFA ANAPURNA M4F M4F, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of AGFA ANAPURNA M4F M4F one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of AGFA ANAPURNA M4F M4F. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of AGFA ANAPURNA M4F M4F should contain:
- informations concerning technical data of AGFA ANAPURNA M4F M4F
- name of the manufacturer and a year of construction of the AGFA ANAPURNA M4F M4F item
- rules of operation, control and maintenance of the AGFA ANAPURNA M4F M4F item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of AGFA ANAPURNA M4F M4F alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of AGFA ANAPURNA M4F M4F, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the AGFA service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of AGFA ANAPURNA M4F M4F.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the AGFA ANAPURNA M4F M4F item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Global Services North America Wilmington MA 01887 : ANAPURNA M4F AGFA UV INKJET PRINTER SITE PREPARATION GUIDE Distribution: Customer Sales Service Dealer 03/17/10 Revision 5.0 Questions? Contact 800-879-2432 and ask for an Anapurna Specialist 1[...]

  • Page 2

    Global Services North America Wilmington MA 01887 Table of Contents Purpose: -------- ---------- ---------- ---------- -- ---------- ---------- -- ---------- ---------- -- ---------- ---------- ---------- -- -- ------ 3 Scope: -------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- -------- ---------- ---------- ------[...]

  • Page 3

    Global Services North America Wilmington MA 01887 Purpose The purpose of this document is to assist the lo cal service represe n tative, who is responsible for configuring and installing the :Anapu rna. This docum ent will help to ensure the site will be re ady and the customer is informed of their re sp onsibilities. Pl ease go through all the inf[...]

  • Page 4

    Global Services North America Wilmington MA 01887 System Dimensions and Weights Dimensions Uncrated Dimensions Crated Weight: H = 63 Inches (1600 mm) H = 71 Inches (1800 mm) Crated: 3087 lbs (1400 Kg) W = 141 Inches (3570 mm) W = 153 Inches (3800 mm) Uncrated:2165 lbs (980 Kg) D = 57 Inches (1450 mm) D = 61 Inches (1550 mm) Dock & building acce[...]

  • Page 5

    Dock & building access Global Services North America Wilmington MA 01887 Foot Print and Working Area: Power and Air Connection Points: The power/air connection p oints are indi cated in the diagram above with the letters A , B , and C A – The power cable entry point lower c hassis – nea r the rear left leveling foot. B – Electrical termin[...]

  • Page 6

    Global Services North America Compressed Air Supply Wilmington MA 01887 Engine Air Connection: An adapter (shown below) is needed to connect the air hose from the air regulator to the printer. This should be purchased locally. Compressor: 3 - 5 HP , min 60 - 80 gallons or better tank. The compressor regulator should be set between 105 - 110 PSI for[...]

  • Page 7

    Global Services North America RIP Software and PC Platform Wilmington MA 01887 Wasatch RIP The Wasatch SoftRip is provided for raster image processing of images. Install the Wasatch SoftRIP on a PC, which meets the following platform specifications. Minimum Recommended System re quirements for Anapurna M4F ¾ CPU Type: Core 2 Duo, 3.06 GHz or faste[...]

  • Page 8

    Global Services North America AC Power Requirements Wilmington MA 01887 Power Requirements for the Anapurna M4F: The following electrical requirements must be provided to your electrician. • Single phase, 208 Y (Wye) power • 40 Amp, 60Hz, dedicated circuit with ground, no neutral • The electrician must provide the proper power cord and plug/r[...]

  • Page 9

    Global Services North America AC Power Requirements Wilmington MA 01887 The Buck/Boost Transformer The Anapurna M4F UV Printers requires power in the 230 – 240 VAC range for the UV lamps to properly cure the ink. At 208 Volts the customer will have curing problems and the lamps will fail prematurely. Buck/Boost Transformer and Specifications: •[...]

  • Page 10

    Global Services North America AC Power Requirements Wilmington MA 01887 Wiring Diagram to Boost Voltage (+32) for Single Phase Power: Input Voltage = 208 V Output Voltage = 236 V This diagram illustrates how to connect a 1.5 KVA, 16/32 Volt buck boost transformer. This wiring configuration boosts the line voltage from 208 to 236 Volts. Diagrams suc[...]

  • Page 11

    Global Services North America AC Power Requirements Wilmington MA 01887 Sample Buck/Boost Transformer: This photo is showing a sample Buck Boost Tran sforme r from Sola Hevi-Duty, it is a 1.5 KVA version, catalog # HS20F1.5A and it weights a p p roximately 38 pounds or 17.2 Kgs. Questions? Contact 800-879-2432 and ask for an Anapurna Specialist 11[...]

  • Page 12

    Global Services North America Wilmington MA 01887 Site Readiness Check List Information to Check Yes No Lateral fork movement capability. Proper lifting rating? ( Pg.4) Forklift Length of forks should be 60 inches (152 .4cm) mi nimum Loading Dock If the customer does not have a loading dock, then the freight truck delivering the Anapurna will need [...]

  • Page 13

    Global Services North America Wilmington MA 01887 Customer Responsibilities The following information has been explaine d to the customer during the site preparation visit. The Customer and his operator(s) are responsible to be skilled in:  Knowledge of PC’s and Networking environment  Knowledge of Windows and Windows Applic ations  Know[...]

  • Page 14

    Global Services North America Wilmington MA 01887 General Information Environmental Requirements Room Operating Tempera ture: Range 68° F to 83° F (20 - 28° C) Ideal 72° F (22° C) (Room air temperature should not to exceed 126º F or 52 ºC) Humidity: Range 35% to 75% RH (non-condensing) Ideal 40% Room Air Exchange: 10 times per hour. The room[...]