ACS EXP-06E manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of ACS EXP-06E, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of ACS EXP-06E one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of ACS EXP-06E. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of ACS EXP-06E should contain:
- informations concerning technical data of ACS EXP-06E
- name of the manufacturer and a year of construction of the ACS EXP-06E item
- rules of operation, control and maintenance of the ACS EXP-06E item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of ACS EXP-06E alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of ACS EXP-06E, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the ACS service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of ACS EXP-06E.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the ACS EXP-06E item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Access Control System EXP-06E Single Door Access Contr oller Installation and Operation Instructions V ersion 6.6 Revision 2003-5[...]

  • Page 2

    EXP-06E Access Control System Installation Instruction Satcom Systems (International) Co., Ltd. 2 1. INTRODUCTION The ACS Access Control System is a powerful software based time recording, access control and integrated security system designed to meet the most demanding access control and point monitoring applications. Programming the system is don[...]

  • Page 3

    EXP-06E Access Control System Installation Instruction Satcom Systems (International) Co., Ltd. 3 2. Hardwar e Requir ements Computer : CPU: Pentium III 800MHz Hard disk space: 500MB RAM: 64MB OS: W indows 98SE English / Chinese version (big5 version) Motherboard: 1 x RS232 port Display: SVGA 800x600 resolution color monitor with 16 bits color Inpu[...]

  • Page 4

    EXP-06E Access Control System Installation Instruction Satcom Systems (International) Co., Ltd. 4 3. EXP-06E Access Contr oller Configuration I/O Capacities IN Reader ----------------------------- 1 IN Keypad ----------------------------- 1 OUT Reader ----------------------------- 1 Electric Door Lo ck Output ----------------------------- 1 Auxilia[...]

  • Page 5

    EXP-06E Access Control System Installation Instruction Satcom Systems (International) Co., Ltd. 5 4. CONFIGURAR TION DIAGRAM Entry Exit A A B C A B EXP- 06E A A D Auxiliary Rela y Output Ala rm Rela y Output Paral lel Printe r Host PC W iring Configur ations Host P C RS232/RS485 Converte r Modem Modem Tel e phon e L ine EXP-0 6E EXP-0 6E 1 32 RS232[...]

  • Page 6

    EXP-06E Access Control System Installation Instruction Satcom Systems (International) Co., Ltd. 6 6. User Card Operation Pr ocedures 6.1 Present Card Only Place the card on the present card area. If the entrance is permitted, the proximity card reader will sound a long "beep". Then the doo r lock will be rel eased with a certain time defi[...]

  • Page 7

    EXP-06E Access Control System Installation Instruction Satcom Systems (International) Co., Ltd. 7 proximity card reader will sound three sort " beep-beep-b eep". For security reason, the key Operation can only be tried 3 times. Af ter than the Key Operation will be terminated for this card only . Card operations then need to reset the ter[...]

  • Page 8

    EXP-06E Access Control System Installation Instruction Satcom Systems (International) Co., Ltd. 8 Otherwise, the proximity card reader will sound three sort "beep-b eep-beep" for rejected active by "INV ALID AUTHORIZE LEVEL" OR "W RONG PIN CODE". Remark : Duress Pin Code is the current user pin code add one. i.e. If th[...]

  • Page 9

    EXP-06E Access Control System Installation Instruction Satcom Systems (International) Co., Ltd. 9 7. INST ALLA TION OF EXP-06E 7.1 Overview of EXP-06E The EXP-06E has two-reader port and one keypad port, capable of handling three relay outputs. The EXP-06E is housed in a 16 A WG metal wall-mounted cabinet. The static RAM consumes minimal power for [...]

  • Page 10

    EXP-06E Access Control System Installation Instruction Satcom Systems (International) Co., Ltd. 10 7.3 Equipment Wiring /r equir ement of EXP-06E 7.3.1 Readers (In/Out) & Keypad 1. Do NOT wiring with any other high power cable. E.g. 220V AC 2. Do NOT ins tall near switches that produce large am ount of spark. E.g. Light. 3. Choose linear power [...]

  • Page 11

    EXP-06E Access Control System Installation Instruction Satcom Systems (International) Co., Ltd. 11 7.4 Connecting the EXP-06E to a host The connector – G, H, I connects a single EXP-06E to the host computer via RS-232C format. Multiple EXP-06E communicates with host from connector – F , E via RS-485 format. But the EXP-06E chain must communicat[...]

  • Page 12

    EXP-06E Access Control System Installation Instruction Satcom Systems (International) Co., Ltd. 12 7.4.4 Configuring the RS-485 Interface Card RS-485 Interface Card is used to communi cate PC and EXP-06E via RS-485 form at. Make sure there are no other devices usi ng COM3 and I/O address (03E8-03EF) in t h e P C b e f o r e installation . If there [...]

  • Page 13

    EXP-06E Access Control System Installation Instruction Satcom Systems (International) Co., Ltd. 13 7.7. Configure Alarm Relay The alarm relay can be activated at the following events: 1. Break In Alarm This is used to enable the break in signal of door . if the door is opened by other matters except door opening door release button or present card [...]

  • Page 14

    EXP-06E Access Control System Installation Instruction Satcom Systems (International) Co., Ltd. 14 8. Specification 8.1 EXP-06E Access Controller CPU : 8031 M e m o r y : 3 2 K B Clock & Data Memory back-up battery : Non-charge 1 month backup during power failure Communication Interface : RS232 and RS485Converter type Data T ransfer Rate (Local[...]

  • Page 15

    EXP-06E Access Control System Installation Instruction Satcom Systems (International) Co., Ltd. 15 Model : SFLA -030-2L Switching Power Suppl y DC1 + 12V( 2A) DC2 - 12V ( 1A) AC-L DC2 AC-N COM DC1 FG Connected to EXP-06 Control ler Board 12V A (+) 12V B (-) 12V O utput f or Electr ic Lock (2 am p.) 12V (+) 12V (-) AC220 V Input JP3 JP7 C5 Par al le[...]