A&D UA-767PBT-C40 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of A&D UA-767PBT-C40, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of A&D UA-767PBT-C40 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of A&D UA-767PBT-C40. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of A&D UA-767PBT-C40 should contain:
- informations concerning technical data of A&D UA-767PBT-C40
- name of the manufacturer and a year of construction of the A&D UA-767PBT-C40 item
- rules of operation, control and maintenance of the A&D UA-767PBT-C40 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of A&D UA-767PBT-C40 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of A&D UA-767PBT-C40, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the A&D service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of A&D UA-767PBT-C40.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the A&D UA-767PBT-C40 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Digital Blood Pressure Monitor Model UA-767 BT Instruction Manual Original Manuel d ’ instructions Traduction Manual de Instrucciones Traducción Manuale di Istruzioni Traduzione Bedienungsanleitung Übersetzung Gebruiksaanwijzing Vertaling 使用手冊 1WMPD4001357D 翻譯[...]

  • Page 2

    English 1 Contents Dear Customers .................................................................... 1 Preliminary Remarks ............................................................. 2 Precautions ........................................................................... 2 Parts Identification ..................................................[...]

  • Page 3

    English 2 Preliminary Remarks This device conforms to the Europe an Directive 93/42 EEC for Medical Products. This is made evident by the mark of conformity. (0123: The reference number to the involved notified body) The device complies with the statutory EMC (Electromagnetic Compatibility) directive 89/336/ EEC. The WML-40AH is approved in accorda[...]

  • Page 4

    English 3 To measure blood pressure, the arm must be squeezed by the cuff hard enough to temporarily stop blood flow through the artery. This may cause pain, numbness or a temporary red mark to the arm. This condition will appear especially when measurement is repeated successively. Any pain, numbness, or red marks will disappear with time. Contrai[...]

  • Page 5

    English 4 Part s Identification Part of Display Pressure Bar Indicator MEMORY Systolic Pressure Diastolic Pressure Pulse Rate Battery Indicator I . H. B . I n d i c a t o r (Irregular heartbeat indicator) Heart Mark Display Air Connector Plug Air Socket Arm Cuff DC Jack START Button Air Hose Index Mark Proper Fit Range Artery Position Mark Battery [...]

  • Page 6

    English 5 Symbols Symbols Function / Meaning Recommended Action Standby and power on. Battery installation guide Direct current SN Serial number Date of manufacture Type BF: Device, cuff and tubing are designed to provide special protection against electrical shocks. The indicator that appears while measurement is in progress. It blinks when the pu[...]

  • Page 7

    English 6 Using the Monitor Inst alling / Changing the Batteries 1. Slide the battery cover up to open it. 2. Remove the used batteries and insert new batteries into the battery compartment as show n, taking care that the polarities (+) and (-) are correct. 3. Slide the battery cover down to close. Use only R6P, AA batteries. CAUTION Insert the bat[...]

  • Page 8

    English 7 Using the Monitor Selecting the Correct Cuff Size Using the correct cuff size is important for an accurate readi ng. If the cuff is not the proper size, the reading may yield an i ncorrect blood pressure value. The arm size is printed on each cuff. The index and proper fit range, on the cuff, te ll you if you are applying the correct cuff[...]

  • Page 9

    English 8 Using the Monitor Applying the Arm Cuff 1. Wrap the cuff around the upper arm, about 1-2 cm above the inside of the elbow, as shown. Place the cuff directly against the skin, as clothing may cause a faint pulse, and result in a measurement error. 2. Constriction of the upper arm, caused by tightly rolling up a shirtsleeve, may prevent acc[...]

  • Page 10

    English 9 Measurement s Model UA-767 BT is designed to detect th e pulse and to inflate the cuff to a systolic pressure level automatically. If your systolic pressure is expec ted to exceed 230 mmHg or you use the optional small cuff, read "Measurem ent with the desired systolic pressure" on the next page. Normal Measurement 1. Place the [...]

  • Page 11

    English 10 Measurements Measurement with the Desired Systolic Pressure If your systolic pressure is expect ed to exceed 230 mmHg or you use the optional small cuff, use this procedure. 1 . P la c e t h e c u f f on t h e arm (preferably the left arm). 2. Press and hold the START button until a number about 30 to 40 mmHg higher than your expected sy[...]

  • Page 12

    English 11 What is an Irregular Heartbeat Model UA-767 BT blood pressure monitor provides a blood pressure and pulse rate measurement ev en when an irregular heartbeat occurs. An irregular heart beat is defined as a heart beat that varies by 25% from the average of all heart beats during the blood pressure measurement. It is important that you be r[...]

  • Page 13

    English 12 Reference Material: Journal of Hyperte nsion 1999, Vol 17 No.2 mmHg 110 105 100 95 90 85 80 Optimal 120 130 140 150 160 170 180 Systolic blood pressure mmHg Normal High-normal Grade 1 hypertension (mild ) Grade 2 hypertension (mode rate) Grade 3 hypertension (severe) Diastolic blood pressure About Blood Pressure What is Blood Pressure? B[...]

  • Page 14

    English 13 Typical fluctuation within a day (Measured every five minutes) PM AM Time Diastolic blood pressure Systolic Diastolic Sleep described in this manual to get to know your normal blood pressure. R egular readings give a more comprehensive bl ood pressure history. Be sure to note date and time when recording your blood pressure. Consult your[...]

  • Page 15

    English 14 Maintenance Do not open the device. It uses delicate electrical components and an intricate air unit that could be da maged. If you cannot fix the problem using the troubleshooting instructi ons, request service from your dealer or from the A&D service group. The A&D service group will provide technical information, spare part s [...]

  • Page 16

    English 15 Applied part Cuff Type BF Useful life Device: 5 years (when used six times a day) Cuff: 2 years (when used six times a day) Wireless communication WML-40AH (M ITSUMI Electronics Co. Ltd.) Accessory AC adapter The adapter is to connect the device to a power source at home. TB-233 Please contact your local A&D dealer for purchasing. Th[...]

  • Page 17

    1-243 Asahi, Kitamoto-shi, Saitama 364-8585 JAPAN Telephone: [81] (48) 593-1111 Fax: [81] (48) 593-1119 A&D INSTRUMENTS LIMITED Unit 24/26 Blacklands Way, Abingdon Busi ness Park, Abingdon, Oxfordshire OX14 1DY United Kingdom Telephone: [44] (1235) 550 420 Fax: [44] (1235) 550485 A&D ENGINEERING, INC. 1756 Automation Parkway, San Jo se, Cal[...]