A&D Medical UA-853 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of A&D Medical UA-853, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of A&D Medical UA-853 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of A&D Medical UA-853. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of A&D Medical UA-853 should contain:
- informations concerning technical data of A&D Medical UA-853
- name of the manufacturer and a year of construction of the A&D Medical UA-853 item
- rules of operation, control and maintenance of the A&D Medical UA-853 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of A&D Medical UA-853 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of A&D Medical UA-853, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the A&D Medical service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of A&D Medical UA-853.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the A&D Medical UA-853 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Premium A utomatic Blood P r essur e M onitor T rilingual Instruction Guide - M odel U A-853 English z F rançais z Español[...]

  • Page 2

    Please read this important information before using y our monitor .  Please remember that only a medical practitioner is qualified to interpr et your blood pressur e measurements. U se of this device should not replace regular medical examinations.  Consult your physician if you have any doubt about y our readings. Should a mechanical problem[...]

  • Page 3

    F ast. Easy . Accurate. Congratulations on purchasing a state-of-the-art L ifeSource® blood pressur e monitor—one of the most technologically advanced monitors available today . Designed for ease of use and accuracy, this monitor will facilitate y our daily blood pressur e r egimen. Physicians agr ee that daily self-monitoring of blood pressur e[...]

  • Page 4

    In Canada - Auto C ontrol Medical ( T oll-F ree): 1-800-461-0991 E-1 T ABLE OF C ONTENTS ? WHA T DISPLA Y SYMBOLS MEAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-2 MONITOR COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-3 HOW UA-853 WORKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .[...]

  • Page 5

    E-2 LifeSource Health Line ( T oll-F ree): 1-888-726-9966 WHA T DISPL A Y SYMBOLS MEAN ? ? Display/ Symbol Measur ement is in progress, remain as still as possible. T ake measurement again and consult with your physician. Replace all batteries with new ones when the symbol blinks. Alkaline batteries recommended. T r y the measurement again. Remain [...]

  • Page 6

    In Canada - Auto C ontrol Medical ( T oll-F ree): 1-800-461-0991 E-3 MONIT OR C OMPONENTS Display MEMORY Button ST ART Button (Orange illumination during the AM) (Blue illumination during the PM) Air Socket AM Button PM Button Air Connector Plug Air Hose Arm Cuff AC A dapter Jack AC A dapter Battery Compar tment Battery Cover FRONT BACK[...]

  • Page 7

    E-4 LifeSource Health Line ( T oll-F ree): 1-888-726-9966 Y ou must install 4 type AA (1.5 v olt) batteries (alkaline batteries recommended), or use the AC A dapter (see page E-14 for using the Monitor with AC A dapter) and attach the cuff to the monitor before using it. T o install batteries (or replace them if the “Low B attery” symbol appear[...]

  • Page 8

    In Canada - Auto C ontrol Medical ( T oll-F ree): 1-800-461-0991 E-5 U sing the correct cuff size is important for an accurate reading. A cuff that is too large will produce a reading that is lo wer than the correct blood pressur e; a cuff that is too small will produce a reading that is higher than the corr ect blood pressure. With your arm hangin[...]

  • Page 9

    E-6 LifeSource Health Line ( T oll-F ree): 1-888-726-9966 Adjusting the Built-in Clock The UA-853 A utomatic Blood P ressure M onitor has a built-in clock that gives you the time and date and can tell you when a blood pressur e reading stored in memory was taken. W e recommend that you adjust the clock prior to use. T o adjust the clock, follow the[...]

  • Page 10

    In Canada - Auto C ontrol Medical ( T oll-F ree): 1-800-461-0991 E-7 Setting the Alar m This monitor has 3 reminder alarms. Y ou can set 3 different r eminder alarms within a 24-hour period. 1. P ress and hold the AM button until the digits start blinking. Then press the MEMOR Y button. “P-1” is shown at the middle line of the display . 2. Sele[...]

  • Page 11

    E-8 LifeSource Health Line ( T oll-F ree): 1-888-726-9966 3. Secure cuff ar ound arm. The cuff should be snug but not too tight. Y ou should be able to insert two fingers between the cuff and your arm. T ips for Blood P ressur e M onitoring:  Relax for about 5 minutes before measur ement.  Do not smoke or ingest caffeine at least 30 minutes p[...]

  • Page 12

    In Canada - Auto C ontrol Medical ( T oll-F ree): 1-800-461-0991 E-9 T AKING Y OUR BL OOD PRESSURE 5. P ress the ST AR T button. As the cuff pressurizes, measur ement will begin and the Cuff I nflation Meter will sho w on the display screen. I t is normal for the cuff to feel very tight. Note: If an appropriate pressure is not obtained , the device[...]

  • Page 13

    E-10 LifeSource Health Line ( T oll-F ree): 1-888-726-9966 M easurement with the desir ed systolic pressur e: If your systolic pressur e is expected to exceed 230 mmHg follow these steps: 1. Place the cuff on the left arm, unless your physician tells you otherwise. 2. Pr ess and hold the ST ART button until a number 30 to 40 mmHg higher than your e[...]

  • Page 14

    In Canada - Auto C ontrol Medical ( T oll-F ree): 1-800-461-0991 E-11 WHA T IS AN IRREGUL AR HEARTBEA T ABOUT CUFF INFLA TION METER The UA-853 B lood Pr essure Monitor pr ovides a blood pressur e and pulse rate measurement even when an irr egular heartbeat occurs. The Irregular Heartbeat symbol will appear in the display window in the event an Irr [...]

  • Page 15

    E-12 LifeSource Health Line ( T oll-F ree): 1-888-726-9966 ABOUT A VERA GE READING The UA-853 pro vides an average blood pressure r eading based on the total measurements stored in memory . The average blood pressure r eading appears briefly when you recall the measurements stored in memory . Y ou can also access your AM/PM A verage Readings b y pr[...]

  • Page 16

    In Canada - Auto C ontrol Medical ( T oll-F ree): 1-800-461-0991 E-13 NO TE: This de vice stores the last 90 measurements in memory . The data is retained as long as the batteries are in the de vice. When you remo ve the batteries or the batteries are dr ained, the data will be er ased. 1. P ress the MEMOR Y button. 2. The average data of all the m[...]

  • Page 17

    E-14 LifeSource Health Line ( T oll-F ree): 1-888-726-9966 USING THE MONIT OR WITH A C ADAPTER The UA-853 has an A C adapter jack to allow you to supply power fr om an outlet in your home. W e recommend you use only the supplied AC adapter to avoid potential damage to the monitor . Connecting the A C adapter to the monitor: 1. Gently insert the AC [...]

  • Page 18

    In Canada - Auto C ontrol Medical ( T oll-F ree): 1-800-461-0991 E-15 What Is Blood Pr essure? Blood pressur e is the force exerted by blood against the walls of the arteries. Systolic pressur e occurs when the heart contracts; diastolic pressure occurs when the heart expands. Blood pressur e is measured in millimeters of mercury (mmHg). What A ffe[...]

  • Page 19

    E-16 LifeSource Health Line ( T oll-F ree): 1-888-726-9966 Assessing High Blood Pressur e for Adults The following standar ds for assessing high blood pressure (without regar d to age or gender) have been established as a guideline. Please note that other risk factors (e.g. diabetes, obesity , smoking, etc.) need to be taken into consideration and [...]

  • Page 20

    In Canada - Auto C ontrol Medical ( T oll-F ree): 1-800-461-0991 E-17 What Is Hypertension? H ypertension (high blood pressure) is the diagnosis given when readings consistently rise above normal. I t is well kno wn that hypertension can lead to stroke, heart attack or other illness if left untreated. Referr ed to as a “ silent killer” because [...]

  • Page 21

    E-18 LifeSource Health Line ( T oll-F ree): 1-888-726-9966 ABOUT BL OOD PRESSURE Answers to Why Y our Readings Are Differ ent Between Home and at the Doctor’ s Office Why are my r eadings different betw een home and at a doctor’ s office? Y our blood pr essure readings taken in a doctor ’ s office or hospital setting may be elevated as a resu[...]

  • Page 22

    In Canada - Auto C ontrol Medical ( T oll-F ree): 1-800-461-0991 E-19 Establishing Baseline Measurements The most important method to get an accurate blood pressure measurement is consistency . T o get the most benefit out of your monitor , it is important to establish a “baseline measurement. ” This helps build a foundation of measurements tha[...]

  • Page 23

    E-20 LifeSource Health Line ( T oll-F ree): 1-888-726-9966 TROUBLESHOO TING N othing appears in the display , after I press the ST AR T button. The cuff does not inflate. The unit does not measure. Readings ar e too high or too low . The value is different from that measured at a clinic or doctor’ s office. Batteries are drained. Battery terminal[...]

  • Page 24

    In Canada - Auto C ontrol Medical ( T oll-F ree): 1-800-461-0991 E-21 SPECIFICA TIONS M odel . . . . . . . . . . . . . . . UA-853 T ype . . . . . . . . . . . . . . . . Oscillometric Display . . . . . . . . . . . . . . . Digital, 20-mm character height P ressure/pulse displayed simultaneously T ime/Date . . . . . . . . . . . . . 12 hour format (AM/P[...]

  • Page 25

    E-22 LifeSource Health Line ( T oll-F ree): 1-888-726-9966 This LifeSource® blood pr essure monitor is co v ered by a Lifetime W arranty . See warranty card for details. Visit our web site at www .LifeSour ceOnline.com for warran ty registration. C ONT A CT INFORMA TION F or more information regar ding use, care or servicing of your blood pressure[...]

  • Page 26

    A division of A&D Engineering, Inc. 1555 M cCandless Drive Milpitas, CA 95035 www .LifeSourceOnline.com PRESSURE RA TING INDICA T OR IS A TRADEMARK OF A&D MEDICAL AND IS P A TENT PENDING. TIMEWISE™ IS A TRADEMARK OF A&D MEDICAL. LIFESOURCE ® IS A REGISTERED TRADEMARK OF A&D MEDICAL. ©2006 A&D MEDICAL. ALL RIGHTS RESERVED. SP[...]