8e6 Technologies Enterprise Filter R3000IR manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of 8e6 Technologies Enterprise Filter R3000IR, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of 8e6 Technologies Enterprise Filter R3000IR one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of 8e6 Technologies Enterprise Filter R3000IR. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of 8e6 Technologies Enterprise Filter R3000IR should contain:
- informations concerning technical data of 8e6 Technologies Enterprise Filter R3000IR
- name of the manufacturer and a year of construction of the 8e6 Technologies Enterprise Filter R3000IR item
- rules of operation, control and maintenance of the 8e6 Technologies Enterprise Filter R3000IR item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of 8e6 Technologies Enterprise Filter R3000IR alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of 8e6 Technologies Enterprise Filter R3000IR, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the 8e6 Technologies service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of 8e6 Technologies Enterprise Filter R3000IR.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the 8e6 Technologies Enterprise Filter R3000IR item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    GUIDE R3000 | Internet F ilter ® QUICK ST ART Model: R3000IR MSA-002-003 R3000 Release: 2.1.10, ER Release: 4.1.20 / Updated: 12.01.08[...]

  • Page 2

    ii 8 e 6 R3000iR Q uick S t aRt G uide 8 e 6 I nternet F Il ter wIth I ntegra ted r eporter Q uIck S t art g uIde © 2008 8e6 T echnologies. All rights reserved. This document may not, in whole or in part, be copied, photocopied, reproduced, translated, or reduced to any elec- tronic medium or machine readable form without prior written consent fro[...]

  • Page 3

    8 e 6 R3000iR Q uick S t aRt G uide iii C ontents R3000IR I ntRoduCtIon .............................................................................. 1 About this Document .................................................................................................................... 2 Conventions Used in this Document ........................[...]

  • Page 4

    iv 8 e 6 R3000iR Q uick S t aRt G uide led I ndICa toRs and B uttons ................................................................... 73 Diagrams and Descriptions ........................................................................................................ 73 R egula toR y s PeCIfICa tIons and d IsClaImeRs ............................[...]

  • Page 5

    8 e 6 R3000iR Q uick S t aRt G uide 1 R3000IR I ntRoduCtIon Thank you for choosing to evaluate the 8e6 T echnologies R3000IR Internet Filter with Integrated Reporter . This product combines the R3000 Internet Filter with the ER Enter- prise Reporter to track end user Internet activity and generate reports that assist admin- istrators in developing [...]

  • Page 6

    2 8 e 6 R3000iR Q uick S t aRt G uide About this Document This document is divided into the following sections: Introduction - This section is comprised of an overview of the R3000IR product and how to use this document Service Information - This section provides 8e6 T echnologies contact information Preliminary Setup Procedures - This section incl[...]

  • Page 7

    8 e 6 R3000iR Q uick S t aRt G uide 3 Conventions Used in this Document The following icons are used throughout this document to call attention to important information pertaining to handling, operation, and maintenance of the server; safety and preservation of the equipment, and personal safety: NOTE: The “note” icon is followed by additional [...]

  • Page 8

    4 8 e 6 R3000iR Q uick S t aRt G uide s eR vICe I nfoRma tIon The user should not attempt any maintenance or service on the unit beyond the proce- dures outlined in this document. Any initial hardware setup problem that cannot be resolved at your internal organiza - tion should be referred to an 8e6 T echnologies solutions engineer or technical sup[...]

  • Page 9

    8 e 6 R3000iR Q uick S t aRt G uide 5 P RelImInaR y s etuP P RoCeduRes Unpack the Unit from the Carton Inspect the packaging container for evidence of mishandling during transit. If the packag- ing container is damaged, photograph it for reference. Carefully unpack the unit from the carton and verify that all accessories are included. Save all pack[...]

  • Page 10

    6 8 e 6 R3000iR Q uick S t aRt G uide Select a Site for the Server The server operates reliably within normal ofce environmental limits. Select a site that meets the following criteria: Clean and relatively free of excess dust. Well-ventilated and away from sources of heat, with the ventilating openings on the server kept free of obstructions. A[...]

  • Page 11

    8 e 6 R3000iR Q uick S t aRt G uide 7 Rack Mount the Server Rack Setup Precautions W arning: Before rack mounting the server , the physical environment should be set up to safely accommodate the server . Be sure that: The weight of all units in the rack is evenly distributed. Mounting of the equipment in the rack should be such that a hazardous con[...]

  • Page 12

    8 8 e 6 R3000iR Q uick S t aRt G uide Rack Mount Instructions Optional: Install the Chassis Rails NOTE: If your chassis does not come with chassis rails, please follow the procedure listed on the last page of this sub-section to install the unit directly into the rack. CAUTION: Please make sure that the chassis covers and chassis rails are installe[...]

  • Page 13

    8 e 6 R3000iR Q uick S t aRt G uide 9 3. Locate the three holes on each side of the chassis and locate the three correspond- ing holes on each of the inner rail. 4. Attach an inner rail to each side of the chassis and secure the inner rail to the chas- sis by inserting three T ype G screws through the holes on each side of the chassis and the inner[...]

  • Page 14

    10 8 e 6 R3000iR Q uick S t aRt G uide Optional: Install the T raditional UP Racks After you have installed the inner rails on the chassis, you are ready to install the outer rails of rail assemblies to the rack. NOTE: The rails are designed to t in the racks with the depth of 28” to 33”. • Determine the placement of each component in the [...]

  • Page 15

    8 e 6 R3000iR Q uick S t aRt G uide 1 1 7. Slide the chassis into the rack as shown below . NOT E: The chas sis may not slide into the rac k smoot hly or easi ly whe n inst alled the rst time. Some adjustment to the slide assemblies might be needed for easy installation. 8. Y ou will need to release the safety taps on both sides of the chassis i[...]

  • Page 16

    12 8 e 6 R3000iR Q uick S t aRt G uide Optional: Install the Open Racks After you have installed the inner rails on the chassis, you are ready to install the outer rails of rail assemblies to the rack. NOTE: The rails are designed to t in the racks with the depth of 28” to 33”. • Determine the placement of each component in the rack before[...]

  • Page 17

    8 e 6 R3000iR Q uick S t aRt G uide 13 3. Attach the front (short) bracket to the front end of the rack, and secure it to the rack with two T ype H screws and T ype I washers as shown below . (See the previous page for descriptions of T ype H and T ype I hardware components.) 4. Attach the rear (long) bracket to the rear end of the rack, and secure[...]

  • Page 18

    14 8 e 6 R3000iR Q uick S t aRt G uide 5. Measure the depth of your rack and adjust the length of the rails accordingly . Then, secure the rails to the chassis with T ype G screws. 6. Slide the inner rails which are attached to the chassis into the outer rails on the rack.[...]

  • Page 19

    8 e 6 R3000iR Q uick S t aRt G uide 15 Install the Chassis into the Rack CAUTION: Before installing the chassis into the rack: • Make sure that the rack is securely anchored onto an unmovable surface or structure before installing the chassis into the rack. • Unplug power cord(s) of the rack before installing the chassis into the rack. • Make[...]

  • Page 20

    16 8 e 6 R3000iR Q uick S t aRt G uide Check the Power Supply This server is equipped with a universal power supply that handles 100-240 V , 50/60 Hz. A standard power cord interface (IEC 950) facilitates power plugs that are suitable for most European, North American, and Pacic Rim countries. Power Supply Precautions W arning: Use a regulating [...]

  • Page 21

    8 e 6 R3000iR Q uick S t aRt G uide 17 General Safety Information Server Operation and Maintenance Precautions W arning: Observe the following safety precautions during server operation and maintenance: W ARNING: If the server is used in a manner not specied by the manufacturer , the protection provided by the server may be impaired. W ARNING: 8[...]

  • Page 22

    18 8 e 6 R3000iR Q uick S t aRt G uide AC Power Cord and Cable Precautions W arning: The AC power cord for the server must be plugged into a grounded, power outlet. Do not modify or use a supplied AC power cord if it is not the exact type required in the region where the server will be installed and used. Replace the cord with the cor- rect type. R[...]

  • Page 23

    8 e 6 R3000iR Q uick S t aRt G uide 19 Motherboard Battery Precautions Caution: The battery on the motherboard should not be replaced without following instructions provided by the manufacturer . Only qualied service personnel should replace batteries. The battery contains energy and, as with all batteries, a malfunction can cause heat, smoke, o[...]

  • Page 24

    20 8 e 6 R3000iR Q uick S t aRt G uide I nst all the s eRveR Step 1: Setup Procedures This step requires you to link the workstation to the R3000IR. Y ou have the option of us- ing the text-based Quick Start setup procedures described in Step 1A, or the Administra- tor console setup procedures described in Step 1B. Quick Start Setup Requirements Th[...]

  • Page 25

    8 e 6 R3000iR Q uick S t aRt G uide 21 Step 1A: Quick Start Setup Procedures Link the W orkstation to the R3000IR Monitor and Keyboard Setup A. Connect the PC monitor and keyboard cables to the rear of the chassis (see Fig. 1). B. T urn on the PC monitor . C. Power on the R3000IR by dropping down the face plate and pressing the large but- ton at th[...]

  • Page 26

    22 8 e 6 R3000iR Q uick S t aRt G uide HyperT erminal Setup Procedures If using a serial console, follow these procedures to create a HyperT erminal session. A. Launch HyperT erminal by going to Start > Programs > Accessories > Communica- tions > HyperT erminal: B. In the Connection Description dialog box, enter any session Name , and t[...]

  • Page 27

    8 e 6 R3000iR Q uick S t aRt G uide 23 D. Specify the following session settings: Bits per second: 9600 Data bits: 8 Parity: None Stop bits: 1 Flow control: Hardware E. Click OK to connect to the HyperT erminal session: • • • • •[...]

  • Page 28

    24 8 e 6 R3000iR Q uick S t aRt G uide F . In the HyperT erminal session window , go to File > Properties to open the Properties dialog box, displaying the Connect T o and Settings tabs: G. Click the Settings tab, and at the Emulation menu select “VT100”. H. Click OK to close the dialog box, and to go to the login screen. NOTE: If usi ng a H[...]

  • Page 29

    8 e 6 R3000iR Q uick S t aRt G uide 25 Login screen The login screen displays after powering on the R3000IR unit using a monitor and key- board, or after creating a HyperT erminal session. NOTE: If the screensaver currently displays on your screen, press the Enter key to display the login screen. A. At the login prompt, type in menu . B. Press the [...]

  • Page 30

    26 8 e 6 R3000iR Q uick S t aRt G uide Quick Start menu: administration menu A. At the Press the number of your selection prompt, press 2 to select the “Quick Start Setup” process. The Quick Start menu takes you to the following conguration screens to make en - tries for conguring the R3000: Change ltering mode Congure network inter[...]

  • Page 31

    8 e 6 R3000iR Q uick S t aRt G uide 27 NOTES: Changing your password using option C, “ Change Quick Start pass - word”, will change the password for the console menu but not the R3000 console login screen. Option A, “ Reset system to factory defaults”, should only be used by an 8e6 T echnologies technical representative. Option D, “ Reset[...]

  • Page 32

    28 8 e 6 R3000iR Q uick S t aRt G uide NOTE: Modications can be made at any time by returning to the specic screen of the Quick Start procedures. Log Off, Disconnect the Peripherals A. After completing the Quick Start setup procedures, return to the Quick Start menu screen and press 9 to log out. B. Disconnect the peripherals from the R3000IR[...]

  • Page 33

    8 e 6 R3000iR Q uick S t aRt G uide 29 Step 1B: Console Setup Procedures Preliminary Setup Create a “setup workstation” using a Windows-based laptop or desktop machine with a network card and Internet Explorer 5.5 (or later). The setup workstation will be used for accessing the R3000 Administrator console on the network and conguring the ser[...]

  • Page 34

    30 8 e 6 R3000iR Q uick S t aRt G uide Link the W orkstation to the R3000IR The procedures outlined in this sub-section require the use of the CA T -5E crossover cable. A. Plug one end of the CA T -5E crossover cable into the R3000IR’s LAN 2 port. NOTE: When facing the rear of the chassis, the LAN 2 port is the port on the right. Portion of MSA c[...]

  • Page 35

    8 e 6 R3000iR Q uick S t aRt G uide 31 The Boot Up Process The boot-up process may take 5 - 10 minutes. When the drive light remains off for 30 seconds, the system is booted up. (See the LED Indicators and Buttons section for a description of front panel LED indicators and buttons.) If you wish to verify that the unit has been booted up, you can pe[...]

  • Page 36

    32 8 e 6 R3000iR Q uick S t aRt G uide Log in to R3000 Administrator Console A. In the console, click the link for Filtering to open the R3000 Introductory Window: NOTE: This window must be left open throughout your session. The Introductory Window displays minimized when the login dialog box of the R3000 Administrator console application opens: B.[...]

  • Page 37

    8 e 6 R3000iR Q uick S t aRt G uide 33 D. Click OK to go to the main screen of the R3000 Administrator console:[...]

  • Page 38

    34 8 e 6 R3000iR Q uick S t aRt G uide Network Click the System button at the top of the screen to go to the System section of the con- sole: In this section of the console you will: Specify the operation mode the R3000 will use for ltering the network, listening to trafc, and sending trafc Congure LAN settings the R3000 will use on you[...]

  • Page 39

    8 e 6 R3000iR Q uick S t aRt G uide 35 Network: Operation Mode From the navigation panel at the left of the screen, click Mode and choose Operation Mode from the pop-up menu: Make the following entries in the Operation Mode window: A. In the Mode frame, select the operational mode the R3000 will use for ltering: Invis - ible, Router , Firewall, [...]

  • Page 40

    36 8 e 6 R3000iR Q uick S t aRt G uide D. Click Apply . Network: LAN Settings From the navigation panel, click Network and choose LAN Settings from the pop-up menu: Make the following entries for the R3000 in the LAN Settings window: A. Enter the Host Name that includes your domain name, for example R3000SER VER. myserver .com (the NetBIOS name mus[...]

  • Page 41

    8 e 6 R3000iR Q uick S t aRt G uide 37 W ARNING: For the router and rewall mode, do not use the same subnet for LAN 1 and LAN 2 or the console will become inaccessible. D. Enter the Primary IP address of the rst DNS name server . The R3000 uses this name server to resolve the domain name requested by users from the LAN. E. Enter the Secondary[...]

  • Page 42

    38 8 e 6 R3000iR Q uick S t aRt G uide The NTP Servers window is used for specifying the Network T ime Protocol (NTP) serv- ers to be used by the R3000, so that the R3000 is synchronized with computer clocks on the Internet. Note that the following server IP addresses display in the Servers list box: 128.59.35.142, 142.3.100.15, 129.132.98.1 1. If [...]

  • Page 43

    8 e 6 R3000iR Q uick S t aRt G uide 39 Network: Regional Setting From the navigation panel, click Network and choose Regional Setting from the pop-up menu: Make the following selections in the Regional Setting window: A. At the Region pull-down menu, select your country from the available choices. B. At the Location pull-down menu, select the time [...]

  • Page 44

    40 8 e 6 R3000iR Q uick S t aRt G uide Physically Connect the R3000IR to the Network Once your R3000 network parameters are set, you must physically connect the unit to your network. This step requires two standard CA T -5E cables. NOTE: This section requires you to restart the R3000. If you wish to relocate the R3000IR before connecting it to the [...]

  • Page 45

    8 e 6 R3000iR Q uick S t aRt G uide 41 Step 2: T est the R3000 Console Connection Now that the R3000IR is physically installed on your network and you have congured its network settings, you need to test the unit to see if it is set up properly . A. Restore the setup workstation you used for the Network Setup to its original settings, and connec[...]

  • Page 46

    42 8 e 6 R3000iR Q uick S t aRt G uide Step 3: T est Filtering or Mobile Client Console Connection T est Filtering If this R3000 has been set up in the Invisible, Router , or Firewall mode, once you have accessed the R3000 Administrator console, you should test ltering. A. T est the R3000’s ltering by opening a browser window on a network w[...]

  • Page 47

    8 e 6 R3000iR Q uick S t aRt G uide 43 Step 4: Set Library Updates After verifying that the R3000 is correctly installed on your network, you need to activate R3000 library updates. Library updates are critical for ltering as new sites are added to the 8e6 library each day . T o activate updates, visit the 8e6 T echnologies Web site and enter th[...]

  • Page 48

    44 8 e 6 R3000iR Q uick S t aRt G uide Perform a Complete Library Update Y our R3000IR was shipped with the latest library update for the current software re- lease. However , as new updates continually become available, before you begin using the R3000IR you must perform a complete library update to ensure you have the latest library updates. T o [...]

  • Page 49

    8 e 6 R3000iR Q uick S t aRt G uide 45 Monitor the Library Update Process T o verify that the library is being updated: A. From the navigation panel, click Updates and select Library Update Log from the menu. B. In the Library Update Log window , click View Log to display the update activity: NOTE: Y ou will be notied in the log when the library[...]

  • Page 50

    46 8 e 6 R3000iR Q uick S t aRt G uide Now that the R3000 is ltering your network, the next step is to set up groups and create ltering proles for group members. T o activate a default lter prole more appropriate for your operations, or to specify a more limited IP range to lter , consult Chapter 2: Group screen in the Global Admi[...]

  • Page 51

    8 e 6 R3000iR Q uick S t aRt G uide 47 Step 5: Change the ER Admin User Name and Password, Set Self-Monitoring After conguring the R3000, click the Quit button at the top of the screen to exit the R3000 Administrator console. Y ou will now need to log in to the ER Administrator con- sole and make some changes to settings in screens. Log in to th[...]

  • Page 52

    48 8 e 6 R3000iR Q uick S t aRt G uide D. Click OK to go to the main screen of the ER Administrator console: Change User Name and Password A. Set up a new administrator user name and password by clicking on the Network pull- down menu and choosing Administrators to display the Add/Edit/Delete Administra- tors screen: B. Select New Administrators fr[...]

  • Page 53

    8 e 6 R3000iR Q uick S t aRt G uide 49 C. Enter a User Name and Password . D. In the Conrm Password eld, re-enter the password. E. Click Save . Set Self-Monitoring A. From the Server pull-down menu, choose Self-Monitoring to display the Self Moni- toring screen: B. Choose YES to activate monitoring. C. Enter the Master Administrator ’ s E-M[...]

  • Page 54

    50 8 e 6 R3000iR Q uick S t aRt G uide Step 6: Client W orkstation Conguration Once your ER is installed, you need to be sure the workstation that will run the client has the following minimum requirements: Pentium III class processor or greater 512 MB RAM minimum, 1 GB RAM recommended 1,024 x 768 display 2 GB free hard drive space Windows 2000 [...]

  • Page 55

    8 e 6 R3000iR Q uick S t aRt G uide 51 Step 7: Launch the ER Client A. Launch IE, enter http://x.x.x.x:8080 or https://x.x.x.x:8443 in the address window (in which “x.x.x.x” represents the IP address of the ER server), and then click Go to access the login window of the ER client. B. Enter your Username and Password , and then click LOGIN to ac[...]

  • Page 56

    52 8 e 6 R3000iR Q uick S t aRt G uide C. In the navigation panel, select Settings , and then choose User Permissions from the menu: D. Click Add User to open the Enter User Permissions dialog box: E. Enter the Username . F . Enter the Password , and Conrm Password . G. Select the User T ype (“Admin” or “Sub-Admin”). H. Click Save to clo[...]

  • Page 57

    8 e 6 R3000iR Q uick S t aRt G uide 53 C onClusIon Congratulations; you have completed the R3000IR quick start procedures. Now that the R3000 and ER are set up on your network, once the ER database is populated with logs from the R3000, the client can be used for generating reports. Initially , you will only be able to report on IP addresses. T o i[...]

  • Page 58

    54 8 e 6 R3000iR Q uick S t aRt G uide B est f Il teRIng P RaCtICes Threat Class Groups 8e6’s ltering library currently consists of 103 library ltering categories, each placed in one of the 20 ltering category groups dened in the interface: Adult Content, Bandwidth, Business/Investments, Community/Organizations, Education, Entertainme[...]

  • Page 59

    8 e 6 R3000iR Q uick S t aRt G uide 55 Filtering Scenarios This collection of ltering scenarios is designed to help you get started ltering the net - work. Each scenario is followed by R3000 setup information. Please consult the “How to” section in the index of the R3000 User Guide for pages containing detailed, step-by-step instructions [...]

  • Page 60

    56 8 e 6 R3000iR Q uick S t aRt G uide T o block categories in a prole using the X Strikes Blocking feature, go to: SYSTEM: System > X Strikes Blocking > Conguration tab, and Categories tab GROUP: Group > IP > member > member Prole > Filter Options tab, X Strikes Blocking enabled or GROUP: Group > Global Group > Glo[...]

  • Page 61

    8 e 6 R3000iR Q uick S t aRt G uide 57 6. Search Engine Keywords Block access to network-endangering content via search engine keywords . In pertinent library categories, enter SE keywords to be blocked. Block these categories in applicable proles. T o set up Search Engine Keywords to be blocked, go to: LIBRARY : Library > Category Groups >[...]

  • Page 62

    58 8 e 6 R3000iR Q uick S t aRt G uide 9. Override Account bypass Use an Override Account to grant a user access to categories blocked at the root level . T o grant designated users access to globally-blocked categories, set up an Override Account at the Global Group level, or enable the option to allow the Mini- mum Filtering Level to be bypassed [...]

  • Page 63

    8 e 6 R3000iR Q uick S t aRt G uide 59 In the R3000 User Guide index, see: • How to: congure ltering • How to: use library categories in a prole 12. File type blocking Prevent users from downloading and using executable les that may threaten your network security . Create a custom category for le extensions and add “.exe” to [...]

  • Page 64

    60 8 e 6 R3000iR Q uick S t aRt G uide 2. Overall Quota Restrict all quota time in a prole to improve bandwidth usage and productivi - ty . Cap the amount of time a user spends in all quota-marked categories by enabling the Overall Quota option and specifying the number of minutes the end user can visit quota-marked categories before being noti?[...]

  • Page 65

    8 e 6 R3000iR Q uick S t aRt G uide 61 In the R3000 User Guide index, see: • How to: congure ltering • How to: congure the Warn Option Setting • How to: use library categories in a prole 5. W arn-strike W arn users before they access unacceptable content and may be locked out of the Internet . Enable the W arn feature along with X[...]

  • Page 66

    62 8 e 6 R3000iR Q uick S t aRt G uide 7. IM patterns Block IM services . Enable Pattern Blocking for all users. In the prole, block Inter - net Communication > Chat and Instant Messaging (IM) categories. T o block IM services, go to: SYSTEM: System > Control > Filter window GROUP: Group > IP > member > member prole > Cat[...]

  • Page 67

    8 e 6 R3000iR Q uick S t aRt G uide 63 10. Remote Access patterns Block remote access patterns . Enable Pattern Blocking for all users. In the prole, block Internet Productivity > Remote Access category . T o block remote access patterns, go to: SYSTEM: System > Control > Filter window GROUP: Group > IP > member > member pro[...]

  • Page 68

    64 8 e 6 R3000iR Q uick S t aRt G uide 13. Rule block Use a rule to block the Bandwidth category . Create a rule that blocks the Band- width category and apply this rule to pertinent proles. T o create and block a rule for the Bandwidth category , go to: GROUP: Group > Global Group > Rules Group > IP > member > member prole >[...]

  • Page 69

    8 e 6 R3000iR Q uick S t aRt G uide 65 In the R3000 User Guide index, see: • How to: set up URL Keywords • How to: set up prole options 16. Custom Block/W arn/X Strikes/Quota pages Customize a block, warning, X Strikes, or quota pages . Modify page contents to point to a URL within your organization, send a request to your administrator ’s[...]

  • Page 70

    66 8 e 6 R3000iR Q uick S t aRt G uide III. General/Productivity 1. W arn Feature with higher thresholds W arn users before they access unacceptable content . Set HTTPS ltering at the “high” level to block certicates that may be questionable. Congure W arning set - tings. In the end user ’s prole, apply the warn option to pertinen[...]

  • Page 71

    8 e 6 R3000iR Q uick S t aRt G uide 67 3. Time Quota/Hit Quota Limit time spent in P ASSED categories to increase productivity . Enable the Quota Settings feature, and congure the Seconds Per Hit. Set up pertinent catego - ries in the user ’s prole with quotas so the user is notied and then locked out of those categories after all minute[...]

  • Page 72

    68 8 e 6 R3000iR Q uick S t aRt G uide 6. Customize an 8e6 Supplied Category Include region-specic content in an 8e6 Supplied category . Add/delete content to/from an existing 8e6 Supplied Category that only includes content pertinent to your organization or region that should be blocked. Apply this category to a prole. T o customize and use [...]

  • Page 73

    8 e 6 R3000iR Q uick S t aRt G uide 69 IV . Pass/Allow 1. Always Allow Custom Category Create a white list custom category . Set up an Always Allow category and add all URLs deemed acceptable. Apply this category to all pertinent proles. T o create a white list custom category and use it in a prole, go to: LIBRARY : Library > Category Grou[...]

  • Page 74

    70 8 e 6 R3000iR Q uick S t aRt G uide 4. Override Accounts Set up override accounts to grant specied users access to URLs blocked for general users . Enable the option to bypass the Minimum Filtering Level using an override account. Create the override account prole, including the accessible cat - egories. T o grant designated users access t[...]

  • Page 75

    8 e 6 R3000iR Q uick S t aRt G uide 71 I mPoRt ant I nfoRma tIon aBout usIng the eR In the e v alua tIon m ode When evaluating the ER and using this product in the evaluation mode, the Expiration screen in the Administrator console and the ER Server Statistics window in the client will display and function differently than they do in the activated [...]

  • Page 76

    72 8 e 6 R3000iR Q uick S t aRt G uide ER Client, ER Server Statistics Window In the ER Server Statistics window , the note “*Evaluation Mode Enabled” displays above the ER Activity frame. T o the right of this note, the Info button displays. When this button is clicked, an alert box opens with the message: “Evaluation Mode – Max Data Stora[...]

  • Page 77

    8 e 6 R3000iR Q uick S t aRt G uide 73 led I ndICa toRs and B utt ons Diagrams and Descriptions LED indicators and buttons for hardware status monitoring display on the front panel, located on the right side of the chassis (see diagram below). Chassis control panel LED Indicator Key Button Key A = Power F = Reset B = HDD Activity G = Power C = LAN [...]

  • Page 78

    74 8 e 6 R3000iR Q uick S t aRt G uide R egula toR y s PeCIfICa tIons and d IsClaImeRs Declaration of the Manufacturer or Importer Safety Compliance USA: UL 60950-1 2nd ed. 2007 Europe: Low V oltage Directive (L VD) 2006/95/EC to CB Scheme EN 60950: 2006 International: UL/CB to IEC 60950-1:2006 Electromagnetic Compatibility (EMC) USA: FCC CFR 47 Pa[...]

  • Page 79

    8 e 6 R3000iR Q uick S t aRt G uide 75 Electromagnetic Compatibility Class A Notice Industry Canada Equipment Standard for Digital Equipment (ICES-003) Bureau of Standards Metrology and Inspection (BSMI) - T aiwan[...]

  • Page 80

    76 8 e 6 R3000iR Q uick S t aRt G uide EC Declaration of Conformity European Community Directives Requirement (CE) Declaration of Conformity Manufacturer ’s Name: 8e6 T echnologies Manufacturer ’s Address: 828 W . T aft Avenue Orange, CA 92865 Application of Council Directive(s): Low V oltage • 2006/95/EC EMC • 2004/108/EC Standard(s): Safe[...]

  • Page 81

    8 e 6 R3000iR Q uick S t aRt G uide 77 I ndex A Always Allow Custom Category 69 B Bandwidth/Productivity 59 boot up 31 BSMI 74, 75 C Category block 55, 63 Change Quick Start password 27 Change User Name and Password 48 crossover cable 20, 30, 40 Custom Block/W arn/X Strikes/Quota pages 65, 68 Custom Category (blocked) 57 Customize an 8e6 Supplied C[...]

  • Page 82

    78 8 e 6 R3000iR Q uick S t aRt G uide L Local category adds/deletes 68 Login screen 25 L VD 74 M Minimum Filtering Level 57 O Overall Quota 60, 67 Overheat 73 Override Account bypass 58 Override Accounts 70 P P2P patterns 61 Pass/Allow 69 Physically Connect the R3000IR to the Network 40 Power Supply Precautions 16 Proxy Patterns 58 Q Quick Start m[...]

  • Page 83

    8 e 6 R3000iR Q uick S t aRt G uide 79 U UL 74 URL exceptions 69 URL Keywords 56, 64 W W arn-strike 61 W arn-strike with higher thresholds 66 W arn Feature with higher thresholds 66 W arn option with low lter settings 60 X X-Strike on blocked categories 55[...]

  • Page 84

    8e6 Corporate Headquarters (USA): 828 West T aft Avenue Orange, CA 92865-4232 • T el: 714.282.61 1 1 or 888.786.7999 Fax: 714.282.61 16 (Sales/T echnical Support) • 714.282.61 17 (General Ofce) Satellite Ofce: 8e6 T aiwan: 7 Fl., No. 1, Sec. 2, Ren-Ai Rd., T aipei 10055, T aiwan, R.O.C. T el: 886-2-2397-0300 • Fax: 886-2-2397-0306[...]